as low overall weight is ideal for applications with
spacing and weight limitations. This easy-to-use
sensor is media resistant, allowing for a broad
range of liquid and gaseous media compatibility.
It can be used at high operating temperatures
and has internal temperature compensation.
Highly reliable, the PTA5000 provides accurate,
high pressure measurements every time.
Specifically designed for industrial applications,
the PTA5000 can be customized to fit your
application-specific needs. So contact us to
place your custom order now.
Standard Full Scale Pressure Ranges
0-100, 0-150, 0-200, 0-300, 0-600,
0-1000, 0-2000, 0-3000, 0-6000, 0-9000
and 0-10000 Psi (Gage)
Features
Hermetically Sealed
Rugged & Durable
Compact & Light-weight
Resistant to Chemical Attack
Superior Long-Term Stability & Repeatability
Outstanding Shock & Vibration Performance
Potsdamer Str. 14, 32423 Minden, Germany
Tel: +49 571 3859-0 - Fax: +49 571 3859-119
Email: info@kavlico.de
235 E. Main St., Suite 102A, Northville, MI 48167, USA
Tel: +1 (248) 465-0815 - Fax: +1 (248) 465-0810
Email: pressure.sensors@kavlico.com
www.kavlico.com
Technical Specifications
psi (gage)
psi (gage)
Proof pressure
psi (gage)
Burst pressure
Individual customized calibration on request.
Electrical
Output Signal
Operating supply voltage
Power consumption
Load
Pressure ranges from 0 to …
100
290
435
150
290
435
200
465
695
300
725
1085
600
1160
1740
1000
1740
2610
2000
4640
6960
3000
5540
7250
6000
8700
11600
9000
13050
17400
10000
13050
17400
4 - 20 mA
8 - 30 VDC
Vsup 8 VDC
0,02 A
0.5 - 4.5 VDC ratiometric
5 VDC ± 5 %
4.7 k
0 - 10 VDC
14 - 30 VDC
4.7 k
Overvoltage protection
min. 33 VDC
Short-circuit proofness
not applicable
Reverse polarity protection
Yes *²)
*¹) for min. 3 intervals at 5 minutes each at max. rated supply voltage
*²) for min. 10 seconds on assigned pins at max. rated supply voltage
min. 6 VDC
Yes *¹)
Yes *²)
min. 33 VDC
Yes *¹)
Yes *²)
Unit shall be supplied by a power supply with double/reinforced insulation (SELV) and limited energy in accordance to UL/EN/IEC 61010-1 or LPS in accordance
to UL/EN/IEC 60950-1 or class 2 per UL1310/UL1585 (NEC or CEC). The power supply shall be approved for usage above 2000m if the pressure sensor is used in
this enviroment. For indoor and outdoor use, not exposed to direct sunlight.
Pin assignment
Current Output
Voltage Output
Connector
PIN 1 / A
PIN 4
PIN 3 / C
PIN 4
PIN 1 / A
PIN 2 / B
PIN 3 / C
PIN 2 / B
M12 4-pole
Vsup
GND
…
Iout
Vsup
…
Vout
…
Packard Metri-Pack 150
Iout
…
Vsup
…
…
GND
Vsup
Vout
Response time
Accuracy
Reference conditions to EN 61298-1
Accuracy *)
Non-linearity **)
0.2 % of span
Non-repeatability
0.1 % of span
1-year stability
0.2 % of span
*) Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2). Adjusted in
vertical mounting position with pressure port down
**) BFSL according to IEC 61298-2
Temperatures
Medium
Environmental
Storage
Temperature coefficients
TC zero
TC span
Conformity
UL
RoHS
CE
Vibration resistance
Shock resistance
Electrical connector
-30 °C to +120 °C
-30 °C to +100 °C (depending on electrical connector)
-30 °C to +100 °C (depending on electrical connector)
0.2 % of span / 10 K within temperature range 0 °C to +80 °C
0.2 % of span / 10 K within temperature range 0 °C to +80 °C
Standard(s) for Safety: Electrical Equipment for Measurement, Control and Laboratory Use - UL 61010-1
According to 2002/95/EC RoHS Directive
Pressure equipment directive 97/23/EC
EMC directive 2004/108/EEC, EN 61 326 Emission (Group 1, Class B)
and Immunity (industrial locations)
IEC 60068-2-64 (RANDOM) 20 PSD
25 g minimum according to EN 60068-2-27
Packard
M12 - 4 pole
Metri-Pack 150 - 3 pole
IP67
Ingress protection
IP67 / IP69K (with special mating connector)
per IEC 60 529
Weight
appr. 50 gram (sensor without mating connector)
Media
All class II fluids and gases compatible with stainless steel 304 (1.4301)
Customized versions on request - contact factory for details.
Potsdamer Str. 14, 32423 Minden, Germany
Tel: +49 571 3859-0 - Fax: +49 571 3859-119
Email: info@kavlico.de
235 E. Main St., Suite 102A, Northville, MI 48167, USA
Before installation and operation, ensure that the appropriate pressure sensor has been selected in terms of pressure range,
design and specific measuring conditions. Non-compliance can result in serious injury and/or damage to the equipment.
Warning: The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any
form of contractual commitment. Kavlico reserve the right to modify their products without notice. It is imperative that we should be consulted over
any particular use or application of our products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that
the product is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application
(such as any modification, addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other
unsuitable material or substance) which has not been expressly agreed by us prior to the sale of our products.
[i=s] This post was last edited by gaon on 2014-7-23 16:34 [/i] Use the FPGA Power Design Tool to record, select the FPGA Power Design Tool tab, the following interface appears, click the PROCESSER bu...
[i=s]This post was last edited by qwqwqw2088 on 2020-3-29 11:22[/i]Silicon carbide (SiC) is a relatively new semiconductor material. To begin with, let's take a look at its physical properties and cha...
In ESP32, two 12-bit successive approximation digital-to-analog converters are built in, managed by five dedicated converter controllers, which can measure analog signals from 18 pins. The ADC can als...
After successfully compiling the project in Keil, the following information will be output in the Build Ouput window below:
Program Size: Code=6320 RO-data=4864 RW-data=44 ZI-data=1636Meaning:
Code: i...
How to make the developed electronic products creative ? How to overcome the difficulties encountered in the process of developing electronic products (such as how to determine product functions, how ...
Emergency hand-held lamps powered by 6V maintenance-free batteries are widely used in rural areas. The charger used is a transformer step-down and single diode half-wave rectifier, and the charging...[Details]
Microchip's PIC18F46J50 is a low-power, high-performance 8-bit USB microcontroller (MCU) using nanoWatt XLP technology. The current in deep sleep mode can be as low as 13nA, the operating voltage i...[Details]
With the rapid development of science and technology, especially the widespread application of digital technology and various ultra-large-scale integrated circuits, electronic equipment, especially...[Details]
Two simple circuits are implemented to drive two LEDs from a battery powered microprocessor.
This design is based on a circuit that uses three resistors and a microprocessor I/O pin as an input h...[Details]
Editor's note: In order to help technicians or engineers who have knowledge of PIC microcontroller assembly language quickly master the method of using C language to program PIC microcontrollers, t...[Details]
AD8205 is
a single-supply high-performance differential
amplifier
launched by
Analog
Devices of the United States
. The typical single-supply voltage is 5V, and its common-mode volta...[Details]
Microcalorimetry
is used to determine energy relationships. Microcalorimetry techniques are often required when performing calorimetric experiments with small sample sizes or slow heating rat...[Details]
1. Introduction to CIF Board
Fieldbus integration based on PC system
Whether it is a master or a slave, fieldbus has won unanimous praise in the field of PC-based automation. For more...[Details]
1 Introduction
In recent years, there have been many major advances in the production technology and processes of automotive headlights, which have greatly improved the performance of automoti...[Details]
LED lamps and bulbs are now rapidly replacing incandescent, halogen and CFL (compact fluorescent lamp) light sources in many general lighting applications. Flyback DC/DC converters are the power su...[Details]
Different initialization between C8051F and 80C51 series microcontrollers
In the past 30 years, major electronic component manufacturers in the world have launched their own unique single-chip...[Details]
introduction
MAX6636 is a multi-channel precision temperature monitor that can not only monitor local temperature, but also connect up to 6 diodes externally. Each channel has a programmable...[Details]
Investment in
the
medical device
industry has been on the rise in recent years. In the past two years, venture capital for medical devices has almost doubled, reaching $4 billion in 2007. Fr...[Details]
Recently, news came from the certification department that the photovoltaic grid-connected inverter of Samil New Energy Co., Ltd. (hereinafter referred to as "Samil New Energy") has once again obta...[Details]
At present, how various communication technologies will evolve after 3G is a focus of great concern in the industry. Especially for TD-SCDMA, whether it can achieve smooth evolution to the next gen...[Details]