Lineup includes models with self-diagnostic output to provide notification of failures and
unstable detection conditions, such as coil burnout.
•
Contributes to preventive maintenance to keep the line from stopping.
Reduced wiring, fewer resources, and low power consumption contribute to
environmentalism.
•
Wiring work and amount of copper wire used reduced to two thirds of that required for 3-wire models.
•
Current consumption drastically reduced to less than 10% (when a DC 2-wire model is compared with a DC 3-wire model).
3-Wire Models
Lineup includes models with small diameter (3 dia., 4 dia., 5.4 dia., M5)
•
All small-diameter models use sealed construction. Operation is stable even when the Sensor is mounted in a small space or embedded in metal.
•
Bright indicators enable easily checking the installation condition.
Wide range of ambient operating temperatures:
−40°C
to 85°C (M8 to M30 models)
•
Wide range of ambient operating temperatures also for small-diameter models:
−25°C
to 70°C
•
Suitable for low-temperature and high-temperature applications, which are troublesome for photoelectric sensors.
Lineup includes models with flexible cable (4-dia. to M30 models)
•
Reduced risk of disconnection in applications with moving parts.
2
E2E
E2E Guide to Selection by Purpose
Environment
Wide
operating
temperature range
−40
to
85°C
AC 2-wire: M12 to M30,
DC 3-wire: M8 to M30
−25
to 70°C
Models not listed above.
Resists the influence of surrounding metal
Shielded Models
Maintenance
Reducing stocked
models
NPN/PNP
output
DC 2-Wire Models
E2E-X@D@
AC/DC 2-Wire Models
E2E-X@T1
Smartclick Pre-wired
Connector Models
E2E-X@D@-M1TGJ-(U)
Pre-wired Connector
Models
E2E-X@D1-M1(G)J-(T)
Connector Models
E2E-X@D@-M1(G)
E2E-X@E@-M1
E2E-X@Y@-M1
AC/DC
Easy replacement
Reducing troubles
Higher oil resistance
Reinforced
Models
with
Oil-resistor
reinforced PUR cable
E2E-X@D@-U
Models
with
Oil-resistant PVC
cable
Robotics Cable Models
E2E-X@D1-R
E2E-X@E1-R
Models
with
a Different
Frequency (NO Models
only)
E2E-X@@15
Standard
Mounting to moving
parts
Robotics cable
Mutual interference
prevention
Miswiring measures
Load short-circuit
protection
DC 2-Wire Models
E2E-X@D@
DC 3-Wire Models
E2E-X@E@
DC 2-Wire
No-polarity
Models
E2E-X@D1-M1J-T
Diagnostic Models
E2E-X@D1S
No
polarity
Early discovery
of problems
Note:
Refer to
Models Not Listed in this Catalog
for Long Body Models, Transmission Couplers, and Power Couplers.
3
E2E
E2E Model Number Legend
E2E-
A B C D E F G
-
H I
-
J
-
K
-
L
No.
A
B
C
Classification
Appearance
Sensing distance
Shielding
Code
C
X
Number
R
Blank
M
B
C
D
E
F
T
Y
1
2
Blank
5
Blank
5
Blank
H
Connection method
M1
M3
Blank
G
I
Connector specifications
J
GJ
TJ
TGJ
J
K
DC 2-wire polarity
Blank
T
Blank
R
U
N
Cylindrical (not threaded)
Cylindrical (threaded)
Sensing distance (Unit: mm)
Indication of decimal point
Shielded Models
Unshielded Models
DC 3-wire PNP open-collector output
DC 3-wire NPN open-collector output
DC 2-wire polarity/no polarity
DC 3-wire NPN collector load built-in output
DC 3-wire PNP collector load built-in output
AC/DC 2-wire
AC 2-wire
Normally open (NO)
Normally closed (NC)
Standard frequency
Different frequency
No
Yes
Pre-wired
M12-size metal connector
M8-size metal connector
Connector Models
DC 3-wire and AC 2-wire, DC 2-wire with self-diagnosis output,
DC 2-wire with old pin arrangement
Connector Models
DC 2-wire with IEC pin arrangement
Pre-wired Connector Models
DC 3-wire and AC 2-wire, DC 2-wire with old pin arrangement
Pre-wired Connector Models
DC 2-wire with IEC pin arrangement
Pre-wired Smartclick Connector Models
DC 2-wire
Pre-wired Smartclick Connector Models
DC 2-wire with IEC pin arrangement
Polarity
No polarity
Standard PVC cable (oil resistant)
Flexible PVC cable (oil resistant)
Polyurethane cable (oil resistant and reinforced)
New model (Applies only to DC 2-wire pre-wired and shielded
models.)
This is blank if the cable
specification in number
K
is R or U.
Example:
Cable length (Unit: m) (Applicable to Pre-wired Models and Pre-
2M
wired Connector Models.)
0.3M
M
Meaning
Remarks
Example:
R6: 0.6 mm
1R5: 1.5 mm
D
Power supply and output
specifications
Whether D models have
polarity is defined by num-
ber
J.
E
F
G
Form of output switching el-
ement
Oscillation frequency type
Self-diagnosis
Used to prevent mutual in-
terference.
Cable specifications
L
M
New model
Cable length
Letter M
Note: The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number.
Models are not available for all combinations of code numbers.
4
E2E
Ordering Information
2-Wire Models
Shielded DC 2-wire Models with No Self-diagnostic Output
[Refer to
Dimensions
on page 27.]
Appear-
ance
Sensing distance
Connection
method
Cable
specifications
Polar-
ity
M12 Pre-wired Smart-
PUR (increased
click Connector Mod-
oil-resistant)
els (0.3m)
PVC (oil-resistant)
PUR (increased
oil-resistant)
PVC (oil-resistant)
M12 Connector Mod-
els
M8 Connector Models
---
---
Yes
Opera-
Pin
tion
arrangement
mode
NO
1: +V, 4: 0 V
NC
NO
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NO
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
---
1: +V, 2: 0 V
1: +V, 4: 0 V
Applicable
connector
code
*2
H
G
Model
E2E-X2D1-M1TGJ-U 0.3M
E2E-X2D2-M1TGJ-U 0.3M
E2E-X2D1-M1TGJ 0.3M
E2E-X2D1-U 2M
E2E-X2D2-U 2M
E2E-X2D1-N 2M
E2E-X2D2-N 2M
E2E-X2D1-M1G
E2E-X2D2-M1G
E2E-X2D1-M3G
E2E-X2D2-M3G
E2E-X3D1-M1TGJ-U 0.3M
E2E-X3D2-M1TGJ-U 0.3M
E2E-X3D1-M1TGJ 0.3M
E2E-X3D1-U 2M
E2E-X3D2-U 2M
E2E-X3D1-N 2M
*1
E2E-X3D2-N 2M
E2E-X3D1-M1G
*1
E2E-X3D2-M1G
E2E-X3D1-M1GJ 0.3M
E2E-X3D2-M1GJ 0.3M
E2E-X3D1-M1J-T 0.3M
M8
2 mm
Pre-wired Models
(2 m)
---
A
D
I
H
G
M12 Pre-wired Smart-
PUR (increased
click Connector Mod-
oil-resistant)
els (0.3m)
PVC (oil-resistant)
PUR (increased
oil-resistant)
PVC (oil-resistant)
M12 Connector Mod-
els
---
Yes
No
*3
Yes
Pre-wired Models
(2 m)
M12
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NO
---
---
3 mm
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
1: +V, 2: 0 V
(3, 4): (+V, 0 V)
(1, 2): (+V, 0 V)
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
A
D
A
D
C
D
H
G
M12 Standard Pre-
wired Connector Mod- PVC (oil-resistant)
els (0.3 m)
M12 Pre-wired Smart-
PUR (increased
click Connector Mod-
oil-resistant)
els (0.3m)
PVC (oil-resistant)
PUR (increased
oil-resistant)
PVC (oil-resistant)
M12 Connector Mod-
els
---
---
E2E-X7D1-M1TGJ-U 0.3M
E2E-X7D2-M1TGJ-U 0.3M
E2E-X7D1-M1TGJ 0.3M
E2E-X7D1-U 2M
E2E-X7D2-U 2M
E2E-X7D1-N 2M
*1
E2E-X7D2-N 2M
E2E-X7D1-M1G
*1
E2E-X7D2-M1G
E2E-X7D1-M1GJ 0.3M
E2E-X7D2-M1GJ 0.3M
E2E-X7D1-M1J-T 0.3M
E2E-X7D2-M1J-T 0.3M
E2E-X10D1-M1TGJ-U 0.3M
E2E-X10D2-M1TGJ-U 0.3M
E2E-X10D1-M1TGJ 0.3M
E2E-X10D1-U 2M
E2E-X10D2-U 2M
E2E-X10D1-N 2M
*1
E2E-X10D2-N 2M
E2E-X10D1-M1G
*1
E2E-X10D2-M1G
E2E-X10D1-M1GJ 0.3M
E2E-X10D2-M1GJ 0.3M
E2E-X10D1-M1J-T 0.3M
E2E-X10D2-M1J-T 0.3M
Pre-wired Models
(2 m)
M18
Yes
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NO
---
---
7 mm
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
1: +V, 2: 0 V
(3, 4): (+V, 0 V)
(1, 2): (+V, 0 V)
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
A
D
A
D
C
D
H
G
M12 Standard Pre-
wired Connector Mod- PVC (oil-resistant)
els (0.3 m)
M12 Pre-wired Smart-
PUR (increased
click Connector Mod-
oil-resistant)
els (0.3m)
PVC (oil-resistant)
PUR (increased
oil-resistant)
PVC (oil-resistant)
M12 Connector Mod-
els
---
Yes
No
*3
Pre-wired Models
(2 m)
M30
Yes
NC
NO
NC
NO
NC
NO
NC
NO
NC
---
---
10 mm
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
1: +V, 2: 0 V
(3, 4): (+V, 0 V)
(1, 2): (+V, 0 V)
A
D
A
D
C
D
M12 Standard Pre-
wired Connector Mod- PVC (oil-resistant)
els (0.3 m)
Yes
No
*3
*1. Models with different frequencies are also available. The model number is E2E-X
@D15
(example: E2E-X3D15-N 2M).
*2. Refer to page 22 for details.
*3. The residual voltage for models without polarity is 5 V, so use caution concerning the connection load interface conditions (e.g., PLC ON voltage).
Are you worried about how to get started with switching power supplies? Are you still lacking practical ability because you only have books but no learning board to learn switching power supplies? Are...
When using the MSCCOMM control, the GetInBufferCount() function can be used to obtain the number of bytes in the serial port buffer, but what function should be used in WINCE?...
When debugging, I found that the program would stop in while(READ_SDA) of IIC_Wait_Ack(). Please help me! ! ! Thank you! ! ! #include "msp430G2553.h" #include "simulation_IIC.h" #include "stdint.h" vo...
I have never worked on ARM before. This month, I need to learn about ARM because of the project requirements. When debugging before, I double-clicked the register under AXD, entered the desired value ...
With the rapid development of science and technology, especially the widespread application of digital technology and various ultra-large-scale integrated circuits, electronic equipment, especially...[Details]
China's new energy vehicles are in a transition period from research and development to real industrial development. In 2012, with the intensive launch of new energy vehicle policy planning, the de...[Details]
In this article, the high-performance DSP developed by TI can be used as an effective confidentiality method if it is applied to PC encryption cards.
As an effective network security solution,...[Details]
This paper establishes a fuel cell engine test platform based on the NI integrated hardware and software environment. This platform can realize the test and control of fuel cell engines and their a...[Details]
1. Principle of displacement angle sensor
The angle sensor is used to detect angles. It has a hole in its body that fits the LEGO axle. When connected to the RCX, the angle sensor counts once ...[Details]
Contact resistance
is the resistance to current flow through a closed pair of contacts. This type of measurement is performed on devices such as connectors,
relays
, and switches. The...[Details]
1. Overview
The Virtual CAN Interface (VCI) function library is an application program interface specifically provided for the use of ZLGCAN devices on PCs. The functions in the library ar...[Details]
1. Project Introduction
Shandong Dezhou Xingtai Paper Co., Ltd. is a newly built high-end paperboard production enterprise with domestic leading level established by Shandong Zhaodongfang Pape...[Details]
1 Introduction to HART Protocol
HART (Highway Addressable Remote Transducer), an open communication protocol for addressable remote sensor high-speed channels, was launched by Rosemen in the U...[Details]
introduction
MAX6636 is a multi-channel precision temperature monitor that can not only monitor local temperature, but also connect up to 6 diodes externally. Each channel has a programmable...[Details]
Continuity test
A variety of devices need to be checked for continuity, including cable assemblies, printed circuit boards, and connectors to ensure that these components have the expected contin...[Details]
With concerns about the growing energy crisis, motor efficiency has become an important and timely topic. This is because motors use 63% to 70% of the electricity produced in the United States and ...[Details]
Abstract: With the development and construction of BeiDou II system, China will shift from the situation dominated by GPS to the situation dominated by BeiDou II global navigation system independen...[Details]
Corelink Semiconductor has launched the CL1100-based 5-7W E27 LED lighting driver system solution DB2. This driver module meets the requirements of small size (L×W×H=5.1cm×2.1cm×1.8cm), low standby...[Details]
LED lighting: Basic circuit design can be completed in as little as one day
Semiconductor manufacturers are also getting involved in the LED lighting business. The power circuit of LED req...[Details]