Parameter NameAttribute value
Product CategoryIndustrial Pressure Sensors
ManufacturerHoneywell
ProductPressure Switches
Operating Pressure3 bar to 16 bar
Pressure TypeDifferential
Accuracy<1 %
Port SizeG 1/2, G 1/4
Operating Supply Voltage250 VAC
Maximum Operating Temperature+ 70 C
Minimum Operating Temperature- 25 C
Mounting StylePanel
Operating Supply Current8 A
PackagingBulk
Pressure PortPort
Factory Pack Quantity1
DWR
Pressure monitors
Especially suitable as a pressure monitor
or pressure limiter for fuel gases (DVGW
Worksheet G 260) and liquid fuels (e.g. fuel oil),
as well as for steam systems according to TRD
604 and hot-water systems to DIN EN12828,
systems in accordance to DIN EN12952-11
SIL 2 according IEC 61508-2
DWR625
Technical data
Pressure connection
External thread G 1/2 (pressure gauge
connection) to DIN 16 288 and internal thread
G 1/4 to ISO 228 Part 1 (for gas applications
internal thread permissible only up to 4 bar).
Switching device
Rugged housing (200) made of seawater-
resistant diecast aluminium.
Materials
Pressure bellows: Material no. 1.4571
Sensor housing: Material no. 1.4104 Switch
housing: GD AI Si 12 (DIN 1725)
Mounting position
Vertically upright and horizontal.
Ambient temperature at switching device
–25 to +70°C,
Medium temperature –25 to +70°C. The
maximum medium temperature at the pressure
sensor must not exceed the permitted ambient
temperature at the switching device.
Temperatures may reach 85°C for short periods.
Higher medium temperatures are possible
provided the above limit values for the switching
device are ensured by suitable measures
(e.g. siphon).
Mounting
Directly on the pressure line (pressure gauge
connection) or on a flat surface with two 4 mm
Ø screws.
Calibration
The DWR series is calibrated for rising pressure.
This means that the adjustable switching pressure
on the scale corresponds to the switching point at
rising pressure. The reset point is lower by the
amount of the switching differential. (See also
page 27, 2. Calibration at upper switching point).
In version ...-203 the switching differential is
adjustable. The basic calibration is maintained.
Bursting pressure
For all types
100 bar, verified by TÜV test.
Switching differential
For values see Product
Summary.
Contact arrangement
Single pole changeover
switch.
Switching
capacity
Normal
250 VAC 250 VDC 24 VDC
(ohm) (ind) (ohm) (ohm)
8A 5A
0.3 A
8A
Component tested for
Function
Direction of action
Sensor
Steam
Systems according to TRBS
Hot water
Systems according to DIN EN12828
Fuel gases
DVGW Worksheet G 260
Pressure tank
DIN EN764-7
Pressure monitor or pressure limiter
(with external interlock)
For maximum and minimum pressure monitoring
(DWFS, SDBFS)
"of special construction"
by testing with 2 million cycles.
Product Summary
Type
Setting range
Switching
differential
(mean values)
Maximum
working
pressure
Dimen-
sioned
drawing
p. 25 + 26
1 + 15
1 + 18
63 bar
1 + 16
63 bar
1 + 16
Protection class
IP 54 according to
DIN 40 050
-DWR
see page 69
s
tested
DVGW
TÜV
Protection Class:
IP 54
Accessories
Solenoid valves
Switching differential adjustable
DWR06–203
0.1…0.6 bar
0.08…0.5
DWR1–203
0.2…1.6 bar
0.15…0.6
DWR3–203
0.2…2.5 bar
0.17…1.2
DWR6–203
0.5…6 bar
0.3…1.4
DWR625–203
0.5…6 bar
0.4…2.5
DWR16–203
3…16 bar
0.75…3.15
DWR25–203
4…25 bar
1.3…6.0
DWR40–203
8…40 bar
2.3…6.6
bar
bar
bar
bar
bar
bar
bar
bar
6 bar
16 bar
25 bar
1 + 15
1 + 18
1 + 17
Flow monitors
Pressure monitors without differential adjustment
DWR06
0.1…0.6 bar
0.04 bar
DWR1
0.2…1.6 bar
0.06 bar
DWR3
0.2…2.5 bar
0.1 bar
DWR6
0.5…6 bar
0.2 bar
DWR625
0.5…6 bar
0.25 bar
DWR16
3…16 bar
0.5 bar
DWR25
4…25 bar
1.0 bar
DWR40
8…40 bar
1.3 bar
6 bar
16 bar
25 bar
1 + 17
Temperature sensors
Thermostats
Pressure transmitters
and DIN EN12953-9. The DWR is used to
monitor maximum and minimum pressures.
This pressure switch is "of special construction"
and has been tested with 2 million operating
cycles. TÜV and DVGW tests exists.
Pressure switches
Mechanical pressure switches
Tested to PE Directive 97/23/EC
59
Excuse me, why can't I burn the program into the PIC microcontroller programmer?
The compilation platform is MPLAB, and the program is burned with PIC microcontroller burner. It was fine just before and could be burned in, but suddenly it can't be burned in, and the program compil...
doob Microchip MCU
Is my understanding of the function of the comparison pin of the switching power supply IC correct? Could you please help me? Thank you.
Many switching power supply ICs have an error inverting input terminal and a non-inverting input terminal, and the comparator output cmp will also be connected to a dedicated pin. The introduction to ...
jonny0811 LED Zone
Identification of Commonly Used Field Effect Transistor Amplifiers
Field Effect Transistor Amplifier 1. Field effect transistors have advantages such as high input impedance and low noise, and are therefore widely used in various electronic devices. In particular, us...
liangqj Test/Measurement
How does a linear regulated power supply pass EMC?
I need help from you all, how can a linear voltage regulated power supply pass EMC? Is there any good way?...
大侠 Integrated technical exchanges
【R7F0C809】Show the board photo, the courier is awesome
I always thought I would get it on Friday, but I didn't expect the courier to be so good this time. It arrived today from Beijing to Jiangsu. Thanks to EE! Thanks to Renesas! For giving me this chance...
770781327 Renesas Electronics MCUs
Please tell me what certification is shown in the picture
Please tell me what certification is shown in the picture...
蓝猫淘气 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 741  2398  1494  2414  996  15  49  31  21  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号