FEATURES
APPLICATIONS
Small Size
–
Good dvdt
–
EN60252-1 rated
AC Application
–
Motor Run
–
AC/DC Motor Controls
–
Switching Power Supplies
Operating Temperature Range
Capacitance Tolerance
Code
WVDC
Peak, AC voltage
(50/60 Hz)
SVDC
VAC
Dissipation Factor (MAX)
Tan δ
at 1 kHz and 25°C
Insulation Resistance
@25°C (<70% RH)for 1 minute
at 100VDC applied
Self Inductance
Dielectric Strength
A04
370
470
160/200
C<2.2uF
.06%
-40°C to +100°C without approvals
-25°C to +85°C with approvals
+10% at 1 kHz, 25°C
+5% optional
A03
A02
A01
A05
500
600
800
1200
625
750
1050
1500
250/320
320/400/430
400/432/500
500/600
2.2<C<15uF
15<C<22uF
C>22uF
.1%
.12%
.15%
10000 MΩ,
C<1uF
3000 MΩxuF,
C>1uF
<1 nano-Henry per mm of lead spacing
Terminal to Terminal
Terminal to Case
160% of VAC for 60 Seconds and 25°C
or 200% VAC applied for 60 Seconds and
25°C for EN 60252-1 approval
3kVAC (50/60 Hz) applied
for 60 Seconds and 25°C
Damp Heat
WVDC
Hours
test
Failure quota
Construction
Coating
Lead terminations
56 days with no voltage applied at +40C and 93%(+2%) relative humidity
Capacitance Change
<+2% of initially measured value
Dissipation Factor
<.001 at 1 kHz for C>0.1uF
Insulation Resistance
>50% of minimum specified value
Class A
Class B
Class C
Class D
Reliability
30000
6000
10000
2000
3000
600
9
1000
200
metallized film
500/10 component hours
Flame Retardant Plastic box with epoxy end fill(UL94V0)
Lead free tinned copper leads
Voltage
code
A04
WVDC/ SVDC
VAC
Agency standard
UL 810
CSA 22.2
Description
Construction only (E192977)
190-M-1985
30000 hrs. Continuous Service
3000 hrs. Continuous Service
Construction only (E192977)
190-M-1985
30000 hrs. Continuous Service
10000 hrs. Continuous Service
3000 hrs. Continuous Service
Construction only (E192977)
190-M-1985
30000 hrs. Continuous Service
10000 hrs. Continuous Service
1000 hrs. Continuous Service
Construction only (E192977)
190-M-1985
30000 hrs. Continuous Service
10000 hrs. Continuous Service
3000 hrs. Continuous Service
Construction only (E192977)
190-M-1985
10000 hrs. Continuous Service
3000 hrs. Continuous Service
Certification
Approval
350/ 425
160
200
UL 810
CSA 22.2
Class A
Class C
A03
500/ 625
275
320
UL 810
CSA 22.2
EN60252-1
EN60252-1
EN60252-1
UL 810
CSA 22.2
EN60252-1
EN60252-1
EN60252-1
UL 810
CSA 22.2
Class A
Class B
Class C
A02
600/ 750
320
400
430
Class A
Class B
Class D
A01
800/ 1050
400
430
500
Class A
Class B
Class C
A05
1200/ 1500
500
600
Class B
Class C
Terminal Style Selection
S5
L30
CXX
MXX
5mm+/-1mm
30mm+/-5mm
Customer specified
Customer specified
Solid tinned copper wire
Solid tinned copper wire
Insulated Solid tinned copper wire
(50-200mm Lead length)
Insulated Stranded tinned copper wire
(50-200mm Lead length)
L
S
d
Lead Spacing
26.5
22.5
0.8
32
27.5
0.8
39.5
35
0.8
42.5
37.5
1.0
Style S5
Style L30
Style CXX, MXX