EEWORLDEEWORLDEEWORLD

Part Number

Search

DGM325-574

Description
Industrial Pressure Sensors FEMA
CategoryThe sensor   
File Size449KB,22 Pages
ManufacturerHoneywell
Websitehttp://www.ssec.honeywell.com/
Download Datasheet Parametric View All

DGM325-574 Online Shopping

Suppliers Part Number Price MOQ In stock  
DGM325-574 - - View Buy Now

DGM325-574 Overview

Industrial Pressure Sensors FEMA

DGM325-574 Parametric

Parameter NameAttribute value
Product CategoryIndustrial Pressure Sensors
ManufacturerHoneywell
ProductPressure Switches
Pressure TypeDifferential
Accuracy< 1 %
Port SizeG 1/2, G 1/4
Operating Supply Voltage250 VAC
Maximum Operating Temperature+ 60 C
Minimum Operating Temperature- 25 C
Mounting StylePanel
Operating Supply Current8 A
PackagingBulk
Pressure PortPort
Factory Pack Quantity1
58
Mechanical pressure switches
Tested to PE Directive 97/23/EC
DGM
Pressure monitors for fuel gases
DVGW tested to DIN EN1854
Gas pressure monitors are suitable
for all gases in accordance with DVGW
Worksheet G260 and for air.
SIL 2 according IEC 61508-2
DGM310A
Technical data
Pressure connection
External thread G 1/2 to DIN 16 288 and
internal thread G 1/4 to ISO 228 Part 1
(permissible up to 4 bar).
Switching device
Seawater-resistant diecast aluminium
GD AI Si 12.
Protection class
IP 54 for vertical installation position.
Pressure sensor materials
See Product Summary
Ambient temperature
–25 to +60°C.
At ambient temperatures below 0°C, ensure
that condensation cannot occur in the sensor
or in the switching device.
Maximum working pressure
See Product Summary
Mounting
Either directly on the pipe or with
two 4 mm ø screws on the wall surface.
Mounting position
Vertically upright and horizontal.
Setting
Continuously adjustable via the setting spindle
with a screwdriver. The set switching pressure
is visible in the scale window.
Sealing P2
On request (can be fitted later).
Switching differentials
Largely independent of the set switching
pressure. Not adjustable. For values see
Product Summary.
Switching
capacity
Normal
250 VAC 250 VDC 24 VDC
(ohm) (ind) (ohm) (ohm)
8A 5A
0.3 A
8A
Component tested for
Testing basis
Function
Fuel gases according to DVGW Worksheet G 260
DIN EN1854
Pressure monitor
Direction of action
For maximum and minimum
pressure monitoring
Product Summary
Type
Setting range
Switching
Max.
differential
working
(mean values) pressure
Materials
Dimen-
in contact
sioned
with medium drawing
p. 25 + 26
DGM306A
DGM310A
DGM325A
DGM06A
DGM1A
DGM506
DGM516
DGM525
15…60
20…100
40…250
100…600
0.2…1.6
15…60
40…160
100…250
mbar
mbar
mbar
mbar
bar
mbar
mbar
mbar
6
7
10
25
40
8
12
20
mbar
mbar
mbar
mbar
mbar
mbar
mbar
mbar
0.8
0.8
0.8
2
3
5
5
5
bar
bar
bar
bar
bar
bar
bar
bar
CU + Ms
CU + Ms
CU + Ms
CU + Ms
CU + Ms
1.4104
1.4104
1.4104
1 + 13
1 + 14
1 +12
Calibration
The
DGM
series is calibrated for rising pressure. This means that the adjustable switching pressure on
the scale corresponds to the switching point at rising pressure. The reset point is lower by the amount of
the switching differential. (See also page 27, 2. Calibration at upper switching point).
For other pressure ranges see type series DWR, page 59.
Ex-i version (intrinsically safe)
As above, but with additional function ZF513 (Ex-i).
Example for ordering:
DGM516-513
Pressure measuring connection
Care must be taken to ensure that a pressure
measuring connection is available in a suitable
place on the gas appliance.
-DGM see page 70
s
DVGW
TÜV
Protection Class:
IP 54
FAQ_How to solve the ADC sampling accuracy problem in BlueNRG-12
Author: ST Engineer Weisheng CHEN Click to download the pdf document to view:Keywords: BlueNRG-1/2, ADCProblem: The sampling accuracy of the ADC module of BlueNRG-1/2 is not high enough. Background: W...
nmg ST - Low Power RF
The computer boot speed is not fast enough after using the following method.
01Step 1: Press the [Ctrl+Alt+Del] keys at the same time, and click [Task Manager] in the window that appears; Step 2: In the Task Manager interface, switch the tab to [Startup], right-click on irrele...
led2015 Talking
Demonstrate opencv face recognition demo on Rayeager PX2
1. Download and compile android according to the tutorial 2. Modify /OpenCV Library - 2.4.9/src/org/opencv/android/JavaCameraView.java. Add exposure in the initializeCamera function. http://bbs.chipsp...
chipspark DIY/Open Source Hardware
DSP2812 Program
When debugging a program with CCS3.3, I encountered this error: declaration may not appear after executable statement in block. Please help me find a solution....
zhangma521 TI Technology Forum
Let's start with 'router'
Usually, when a family wants to share the Internet, they will buy a "SOHO router" for about 100 to 300 yuan in the market, and connect the WAN port of such a small box to the Internet through ADSL (PP...
richiefang RF/Wirelessly
【Learn Power Supply from TI】Series----2012 TI Industrial Technology and Product Seminar Materials (Welcome to download!!!)
[size=6][color=darkred]2012 TI Industrial Technology and Product Seminar Materials (PDF format, welcome to download!!!)[/color][/size]...
qwqwqw2088 Analogue and Mixed Signal

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1830  95  1749  1290  68  37  2  36  26  58 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号