EEWORLDEEWORLDEEWORLD

Part Number

Search

PJ24208RTW

Description
Electrical Enclosures 4X Polyester wWindow RaisedLid/TwistLatch
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size174KB,3 Pages
ManufacturerHammond
Websitehttp://www.hammondmfg.com
Download Datasheet Parametric View All

PJ24208RTW Online Shopping

Suppliers Part Number Price MOQ In stock  
PJ24208RTW - - View Buy Now

PJ24208RTW Overview

Electrical Enclosures 4X Polyester wWindow RaisedLid/TwistLatch

PJ24208RTW Parametric

Parameter NameAttribute value
Product CategoryElectrical Enclosures
ManufacturerHammond
RoHSDetails
ProductBoxes
TypeWindowed
ColorGray
Length24 in
Width20 in
Height8.13 in
IP RatingIP66
NEMA Rating1, 2, 3, 4, 4X, 12, 13
Factory Pack Quantity1
Unit Weight19 lbs
11/29/2017
Type 4X Polyester Junction Box w/ Raised Lid (Solid and Window) (PJ Series) - Hammond Mfg.
Quality Products. Service Excellence.
Type 4X Polyester Junction Box w/ Raised Lid (Solid and Window)
PJ Series
Continuous Hinge Door with Twist Latches
Application
Designed for use as instrument enclosures, electric, hydraulic or pneumatic control
housings, electrical junction boxes or terminal wiring enclosures.
Provides outstanding insulation and protection where equipment may be hosed down or
be very wet.
Ideal in applications with high temperatures or highly corrosive environments.
Standards
UL 508A Type 1, 2, 3, 4, 4X, 12 and 13
CSA Type 1, 2, 3, 4, 4X, 12 and 13
Complies with
NEMA Type 1, 2, 3, 4, 4X, 12, & 13
IEC 60529, IP66
Construction
Molded fiberglass polyester enclosure with matching cover is easily punched, cut, or
drilled.
Enhanced UV inhibitors protect against outdoor weathering.
Threaded brass inserts are provided for optional inner panel or terminal kit mounting.
Mounting hardware is included.
Stainless steel draw type "twist latch" door fasteners.
Door fasteners include a provision for padlocking.
Enclosures are available with bonded polycarbonate viewing windows.
Door is supported with a continuous stainless steel hinge.
Captive oil resistant gasket provides a positive seal.
Threaded brass inserts are provided for mounting feet to the rear of the enclosure.
Stainless steel mounting brackets and hardware are provided for mounting to the rear of
the enclosure.
Operating temperatures between 130°C and -40°C (266°F to -40°F).
Impact index of 6.78J (5 ft/lb).
For corrosion resistance information, please refer to table in the Technical Information
section.
Finish
Fiberglass polyester material has a gray finish.
Optional inner panels are available in white powder coated finished steel or unfinished
aluminum, or fiberglass.
Accessories
PJ/PJU Replacement Hardware Kits
Swing Panels
Inner Panels
Terminal Kit Assemblies
https://www.hammfg.com/electrical/products/corrosion/pjrt
1/3
Integrated operational amplifier practical circuit diagram
This book introduces the basic knowledge of integrated operational amplifier circuits and explains the diagram reading. It introduces the characteristics, parameter detection and working principle of ...
arui1999 Download Centre
How to enable the scanning function of the handheld terminal
I am using symbol MC3090 as hardware and c#2005 as platform to develop a mobile data acquisition software. Now I have a problem, that is, how to turn on the scanner on the RF when opening a module, an...
blueeyeheyin Embedded System
Selection and development of level gauges for petrochemical tank area liquid level measurement
[color=#666666]This article shares the common methods and principles of tank level measurement in petrochemical enterprises at home and abroad, analyzes the commonly used oil tank level instruments, a...
yunrun Industrial Control Electronics
How to ADD 8-bit data of MSP430 IO directly into R register?
Urgent help: How can I add the 8-bit data of the MSP430F51XX IO directly to the R register through the ADD command? I can use MSP430F149 to implement the ADD &P2IN_,0(R4) operation, but the original o...
yuguyu Microcontroller MCU
Rookie help! A program just can't be adjusted
In a temperature measurement program, there is a section where data is written to the chip. It won't work if you put writing 1 and 0 in the sub-function. Don't know why. The program is quite simple as...
loviss2012 51mcu
How to solve the problem of rpc timeout in nfs file under linux?
It prompts that nfs has been started correctly, but it always prompts that RPC timed out and the mount failed?...
ac0613 Linux and Android

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1389  2378  1934  2266  1216  28  48  39  46  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号