EEWORLDEEWORLDEEWORLD

Part Number

Search

0226

Description
Enclosures, Boxes, u0026 Cases COVER FOR 0225
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size87KB,1 Pages
ManufacturerDavies Molding
Download Datasheet Parametric View All

0226 Online Shopping

Suppliers Part Number Price MOQ In stock  
0226 - - View Buy Now

0226 Overview

Enclosures, Boxes, u0026 Cases COVER FOR 0225

0226 Parametric

Parameter NameAttribute value
Product CategoryEnclosures, Boxes, & Cases
ManufacturerDavies Molding
RoHSDetails
ProductBoxes
TypeAccessories, Cover Panel
Factory Pack Quantity200
Unit Weight5.696110 oz
Next
Previous
Axial Lead and Cartridge Fuses
Designed to IEC Standard
5 x 20 mm
Fast-Acting Fuse 216/226 Series
• Designed to International (IEC) Standards for use globally.
• Meets the IEC 60127-2, Sheet 1 specification for Fast Acting Fuses.
• Available in Cartridge and Axial Lead Form.
• Available in ratings of 0.050 to 10 amperes.
• High breaking capacity.
®
®
D
V
E
ELECTRICAL CHARACTERISTICS:
% of Ampere
Rating
150%
210%
275%
400%
1000%
Ampere
Rating
.05 – 3.15
4– 6.3
.05 – 3.15
4– 6.3
.05 – 3.15
4– 6.3
.05 – 3.15
4– 6.3
.05 – 3.15
4– 6.3
Opening
Time
60 minutes,
Minimum
60 minutes,
Minimum
30 minutes,
Maximum
30 minutes,
Maximum
0.01 sec.,
Min.;
2 sec.
Max.
0.01 sec.,
Min.;
3 sec.
Max.
.003 sec.,
Min.;
0.3 sec.
Max.
.003 sec.,
Min.;
0.3 sec.
Max.
.02 seconds,
Maximum
.02 seconds,
Maximum
5
(.197")
216
000
Series
216
000
XE
226
000
Series
1
.635
(.025")
AGENCY APPROVALS:
Sheet I IEC 60127-2:* SEMKO approved
thru 6.3 amps. Recognized under the Components Program of
Underwriters Laboratories and recognized by CSA. BSI approved 1A to
6.3A. VDE approved .05-6.3.
20
(.787")
5.25
(.207")
22.5 MAX
(.886)
40
(1.58")
INTERRUPTING RATING:
1500 amperes.
ORDERING INFORMATION:
Cartridge
Catalog
Number
216.050
216.063
216.080
216.100
216.125
216.160
216.200
216.250
216.315
216.400
216.500
216.630
216.800
216
001
216
1.25
216
01.6
216
002
216
02.5
216
3.15
216
004
216
005
216
06.3
216
008
216
010
Axial Lead
Catalog
Number
226.050
226.063
226.080
226.100
226.125
226.160
226.200
226.250
226.315
226.400
226.500
226.630
226.800
226
001
226
1.25
226
01.6
226
002
226
02.5
226
3.15
226
004
226
005
226
06.3
226
008
226
010
Ampere
Rating
.050
.063
.080
.100
.125
.160
.200
.250
.315
.400
.500
.630
.800
1
1.25
1.6
2
2.5
3.15
4
5
6.3
8*
10*
Voltage
Rating
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
Nominal
Resistance
Cold Ohms
15.90
10.45
7.89
5.42
3.68
5.20
3.35
2.35
1.85
1.67
1.20
0.790
0.588
0.228
0.153
0.108
0.0770
0.0575
0.0333
0.0243
0.0168
0.0125
0.0120
0.00775
Nominal
Melting I
2
t
A
2
Sec.
0.00019
0.00055
0.00086
0.0033
0.0056
0.0018
0.0045
0.0092
0.015
0.028
0.045
0.097
0.18
0.19
0.49
1.04
1.92
2.77
7.85
15.4
28.2
57.9
66.1
158.5
Average Time Current Curves
.100A
.125A
.160A
.200A
.250A
.315A
.500A
.630A
.800A
1A
1.25A
1.6A
2A
2.5A
3.15A
4A
5A
6.3A
10A
1
10
CURRENT IN AMPERES
100
10
TIME IN SECONDS
1
0.1
0.01
*IEC Standards for 5 x 20mm fuses do not include ratings above
6.3 amperes, but are under consideration.
0.001
0.05 0.1
100
500
1
226 Series is used for North American ordering.
296
w w w. l i t t e l f u s e . c o m

Recommended Resources

Christmas is coming, the most lively place in China
Today I went to the most lively place in China on Christmas Day—the property transfer hall!!! It was really noisy with loud drums and gongs, and huge crowds of people... It was as noisy as a vegetable...
crazyk Talking
How to get the double-click message of static controls in WinCE?
In VC, you only need to inherit a class from CStatic, check the "Notify" property, overload the double-click message, and get it in its message processing function, but it doesn't work in EVC. Has any...
mz6605 Embedded System
Some thoughts on 99 shortcut keys
I have nothing to do, so I saw some of my commonly used 99se shortcut keys, and I would like to share my thoughts: In many places, you can find a lot of descriptions of 99se shortcut keys. But I perso...
heningbo PCB Design
Why does the compilation of stm32f407 remain unchanged after modifying the ROM address?
I created a project and wanted it to start executing from 0x8020000, so I changed the address in Keil's ROM settings. But the address of the compiled hex file is still 0x8000000. I would like to ask w...
helenhll stm32/stm8
How do I set the parameters of iosIoctl to non-block the socket under VX WORKS?
How do I set the parameters of iosIoctl to non-block the socket under VX WORKS?...
qqqyyy10000 Embedded System
Senior students ask experts for help with microcontrollers
I have many questions about my graduation project and I need help...
wq290990944 51mcu

Popular Articles

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1306  720  2467  1691  1712  27  15  50  35  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号