as low overall weight is ideal for applications with
spacing and weight limitations. This easy-to-use
sensor is media resistant, allowing for a broad
range of liquid and gaseous media compatibility.
It can be used at high operating temperatures
and has internal temperature compensation.
Highly reliable, the PTA5000 provides accurate,
high pressure measurements every time.
Specifically designed for industrial applications,
the PTA5000 can be customized to fit your
application-specific needs. So contact us to
place your custom order now.
Standard Full Scale Pressure Ranges
0-100, 0-150, 0-200, 0-300, 0-600,
0-1000, 0-2000, 0-3000, 0-6000, 0-9000
and 0-10000 Psi (Gage)
Features
Hermetically Sealed
Rugged & Durable
Compact & Light-weight
Resistant to Chemical Attack
Superior Long-Term Stability & Repeatability
Outstanding Shock & Vibration Performance
Potsdamer Str. 14, 32423 Minden, Germany
Tel: +49 571 3859-0 - Fax: +49 571 3859-119
Email: info@kavlico.de
235 E. Main St., Suite 102A, Northville, MI 48167, USA
Tel: +1 (248) 465-0815 - Fax: +1 (248) 465-0810
Email: pressure.sensors@kavlico.com
www.kavlico.com
Technical Specifications
psi (gage)
psi (gage)
Proof pressure
psi (gage)
Burst pressure
Individual customized calibration on request.
Electrical
Output Signal
Operating supply voltage
Power consumption
Load
Pressure ranges from 0 to …
100
290
435
150
290
435
200
465
695
300
725
1085
600
1160
1740
1000
1740
2610
2000
4640
6960
3000
5540
7250
6000
8700
11600
9000
13050
17400
10000
13050
17400
4 - 20 mA
8 - 30 VDC
Vsup 8 VDC
0,02 A
0.5 - 4.5 VDC ratiometric
5 VDC ± 5 %
4.7 k
0 - 10 VDC
14 - 30 VDC
4.7 k
Overvoltage protection
min. 33 VDC
Short-circuit proofness
not applicable
Reverse polarity protection
Yes *²)
*¹) for min. 3 intervals at 5 minutes each at max. rated supply voltage
*²) for min. 10 seconds on assigned pins at max. rated supply voltage
min. 6 VDC
Yes *¹)
Yes *²)
min. 33 VDC
Yes *¹)
Yes *²)
Unit shall be supplied by a power supply with double/reinforced insulation (SELV) and limited energy in accordance to UL/EN/IEC 61010-1 or LPS in accordance
to UL/EN/IEC 60950-1 or class 2 per UL1310/UL1585 (NEC or CEC). The power supply shall be approved for usage above 2000m if the pressure sensor is used in
this enviroment. For indoor and outdoor use, not exposed to direct sunlight.
Pin assignment
Current Output
Voltage Output
Connector
PIN 1 / A
PIN 4
PIN 3 / C
PIN 4
PIN 1 / A
PIN 2 / B
PIN 3 / C
PIN 2 / B
M12 4-pole
Vsup
GND
…
Iout
Vsup
…
Vout
…
Packard Metri-Pack 150
Iout
…
Vsup
…
…
GND
Vsup
Vout
Response time
Accuracy
Reference conditions to EN 61298-1
Accuracy *)
Non-linearity **)
0.2 % of span
Non-repeatability
0.1 % of span
1-year stability
0.2 % of span
*) Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2). Adjusted in
vertical mounting position with pressure port down
**) BFSL according to IEC 61298-2
Temperatures
Medium
Environmental
Storage
Temperature coefficients
TC zero
TC span
Conformity
UL
RoHS
CE
Vibration resistance
Shock resistance
Electrical connector
-30 °C to +120 °C
-30 °C to +100 °C (depending on electrical connector)
-30 °C to +100 °C (depending on electrical connector)
0.2 % of span / 10 K within temperature range 0 °C to +80 °C
0.2 % of span / 10 K within temperature range 0 °C to +80 °C
Standard(s) for Safety: Electrical Equipment for Measurement, Control and Laboratory Use - UL 61010-1
According to 2002/95/EC RoHS Directive
Pressure equipment directive 97/23/EC
EMC directive 2004/108/EEC, EN 61 326 Emission (Group 1, Class B)
and Immunity (industrial locations)
IEC 60068-2-64 (RANDOM) 20 PSD
25 g minimum according to EN 60068-2-27
Packard
M12 - 4 pole
Metri-Pack 150 - 3 pole
IP67
Ingress protection
IP67 / IP69K (with special mating connector)
per IEC 60 529
Weight
appr. 50 gram (sensor without mating connector)
Media
All class II fluids and gases compatible with stainless steel 304 (1.4301)
Customized versions on request - contact factory for details.
Potsdamer Str. 14, 32423 Minden, Germany
Tel: +49 571 3859-0 - Fax: +49 571 3859-119
Email: info@kavlico.de
235 E. Main St., Suite 102A, Northville, MI 48167, USA
Before installation and operation, ensure that the appropriate pressure sensor has been selected in terms of pressure range,
design and specific measuring conditions. Non-compliance can result in serious injury and/or damage to the equipment.
Warning: The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any
form of contractual commitment. Kavlico reserve the right to modify their products without notice. It is imperative that we should be consulted over
any particular use or application of our products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that
the product is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application
(such as any modification, addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other
unsuitable material or substance) which has not been expressly agreed by us prior to the sale of our products.
From the tool manuals of ST, it can be seen that technology piracy has strengthened technology confidentiality, reduced technology exchange, and reduced the driving force of technological development....
[align=center][size=5][b]Recommendation of excellent books on development (XVIII) --- Embedded systems - Hardware and software architecture [/b][/size][/align] [size=4]With the rapid development of el...
I only added these few sentences, opened serial port 0 PINSEL0=0x05; U1LCR=0x83; U0DLL=0x6C; U0LCR=0x03; Why is a character sent out as soon as it runs? What is the reason? How can I delete it?...
[i=s]This post was last edited by allenliu on 2017-4-10 01:54[/i] [b][size=3]Test environment[/size][/b] [b][size=3]Node[/size][/b] The remote node A is powered by a mobile power supply (the CR2032 ba...
There are several points below, which I would like to discuss with you. 1. I think point A in the figure can be disconnected, and these current limiting resistors can be removed without affecting the ...
Most recently, NASA's Perseverance rover landed in the Jezero Crater on Mars on February 18, 2021. According to NASA, the rover will "search for signs of ancient life and collect rock and regolith sam...
No matter which processor you are learning, the first thing you need to understand is the registers and working mode of the processor.
ARM has 37 registers, including 31 general registers and ...[Details]
In recent years, the market for mobile/portable devices such as smartphones and laptops has continued to grow rapidly. While these products continue to integrate more new features to enhance the ...[Details]
1. Introduction
Light control circuit plays a vital role in urban street lamps or corridor lighting. With light control circuit, the lights can be automatically turned on and off according to ...[Details]
Aromatic gases are widely present in food, medicine, cosmetics and various daily chemical products, such as snacks, liquor, spices, Chinese herbal medicines, plasters, perfumes, soaps, shampoos, et...[Details]
Since the No. 4 blast furnace of Handan Iron and Steel was put into operation in 1993, its external equipment has been seriously aged, and the original PLC control system TDC3000 of the hot blast furn...[Details]
Abstract: Aiming at the needs of coal-rock acoustic emission signal monitoring system, a data acquisition circuit with 24-bit resolution and 16-channel synchronous data acquisition function is desi...[Details]
System Overview
The system consists of a signal preprocessing circuit, a single-chip computer AT89C2051, a systematic LED display module, a serial port data storage circuit and system software...[Details]
Temperature compensated quartz crystal oscillator (TCXO) is widely used as a high-precision frequency source in communication systems, radar navigation systems, precision measurement and control sy...[Details]
One in five car failures are caused by batteries, a problem that will become more serious in the coming years as electric-by-wire, start/stop engine management and hybrid (electric/gas) vehicles be...[Details]
Leakage current is generated by parasitic resistance paths between the measurement circuit and a nearby voltage source. This current can significantly reduce the accuracy of low current measurement...[Details]
The future energy storage hotspot is not coal or iron ore, but lithium. This lightest metal in nature may be the heaviest resource in the future energy landscape. China launched an ambitious electr...[Details]
DCDC means DC to DC (conversion of different DC power values). Anything that meets this definition can be called a DCDC converter. Specifically, it means converting the input DC into AC through a s...[Details]
Measurement compatibility
It is very important to ensure the compatibility between the pressure sensor and its actual application. Before making a pressure sensor selection, the fo...[Details]
This paper describes the design method of electronic multifunctional watt-hour meter, the key technology of hardware design and the software design process. Taking NEC's μPD78F0338 microcontroller ...[Details]
Preface
DS18B2 is generally used in conjunction with a single-chip microcomputer, and there are few reports on
the interface between
DSP
and DS18B20. Therefore, this article introdu...[Details]