Packard Electric Metri-Pack 150 Series, 12” 20” AWG leads
1/4-18 NPT (external), 3/8-24 UNF-2A (male) *
1
303 Stainless Steel
0.5 - 4.5 VDC
Attributes
▀
▀
▀
▀
▀
▀
▀
▀
▀
▀
Typical Applications
▀
▀
▀
▀
▀
▀
▀
▀
▀
Dry Media *
2
Superior Long Term Stability
Excellent Repeatability/Hysteresis
Superior EMI/RFI Rejection
Low Power Consumption
Linear Output
Temperature Compensated
Over-Voltage, Reverse Polarity & Short Circuit Protection
Ten Million Cycle Life Expectancy
Outstanding Shock & Vibration Performance
Steam Sterilizers
Gasoline & Diesel Engines
Natural Gas & CNG Engines
Agricultural Chemical Equipment
Level Measurement
Test Equipment
Injection Molding
Coolant Pressure
Industrial Compressors
2. For wet conductive media please contact us
Description
The model P265 is based on Kavlico’s field proven ceramic capacitive technology with the latest state-of-the-art
ASIC. Featuring a 303SS housing, the P265 is designed for general use wherever a rugged and reliable pressure
transducer is required. The P265 package has a built-in MetriPack 150, electrical connector and supports
popular process connection threads. The P265 is offered with a variety of seal materials and is suitable for many
diverse applications. Specifically intended for OEM applications, the P265 delivers a cost effective solution
without compromising performance or reliability.
www.kavlico.com
Technical Specifications
Pressure Ranges
From 0 to …
PSIA,
PSIG, 1 5
PSIS
PSIA, 75
PSIG,
PSIS
PSIA, 1000
PSIG,
PSIS
20
100
30
150
50
250
75
375
100
300
150
450
200
600
300
900
500
1500
750
1500
1000
2000
Proof pressure
1000
1000
1000
1000
2000
2000
2000
2000
2000
2000
2000
Burst pressure
Physical
Operating Life Cycle
Vibration Resistance
Shock Resistance
Drop Test
Weight
Ingress Protection
Operating Temperature
Storage Temperature
Media
2. for more details see How to Order
min. 10 million full pressure cycles over the full range
10 G’s peak to peak sinusoidal (10 to 2000 Hz)
75 G’s ½ sinewave
1 meter drop on concrete as per SAE J1455 / DIN EN 60068-2-3-1
≤
100 grams (without mating connector)
IP 65 or IP67 - depending on electrical connector
-40°C to 125°C (depending on seal material) *
2
-40°C to 125°C (depending on seal material) *
2
All class II fluids and gases compatible with stainless steel 303 and the internal seal
ring material
Performance
Total error band *
3
Stability coefficient
Temp. Coefficients - Zero
Temp. Coefficients - Span
+/-2% of span (-20
≤
T
≤
100° C) +/-3% of span (T < -20° C,T < 100° C)
+/-0.5 % of full span over 1 year
0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %
0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %
3. Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2). Adjusted in vertical mounting position with pressure port down
www.kavlico.com
Data Sheet P265
2
Electrical
Output Signal
Operating Supply Signal
Power Consumption
Overvoltage Protection
Short-circuit Proofness
Insulation Voltage
Reverse Polarity Protection
Load
Response Time
4. for min. 3 intervals at 5 minutes each
5. for min. 10 seconds on assigned pins
0.5…4.5 VDC Ratiometric
5 VDC ± 10%
≤
25 mW
16 VDC
Yes
*4
500 VDC
Yes *
5
≥
25 kΩ
15 ms max. to 63% of full scale pressure with step change on input
Approvals & Certificates
ROHS
2011/65/EU ROHS Directive
www.kavlico.com
Data Sheet P265
3
Dimensions
Before installation and operation, ensure that the appropriate pressure sensor has been selected in terms of pressure range, design and specific measuring
conditions. Non-compliance can result in serious injury and/or damage to the equipment.
Warning:
The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any form
of contractual commitment. Kavlico reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular
use or application of our products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product is suitable
for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification,
addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance)
which has not been expressly agreed by us prior to the sale of our products.
www.kavlico.com
Data Sheet P265
4
How to Order
Seal Material
B Nitrile
C Neoprene
D Fluorocarbon
E Fluorosilicone
F Ethylene Propylene
Pressure Connection (port)
1 1/4 - 18 NPT (External Threads)
2 3/8 - 24 UNF-2A (Male)
3 3/8 - 24 UNF-2B (Female)
4 1/8 - 27 NPT
P265
500
S
Reference
A Absolute
G Gage
S Sealed Gage
F
1
A
Pressure Ranges
0 - 15 PSI
15
0 - 20 PSI
0 - 30 PSI
0 - 50 PSI
0 - 75 PSI
0 - 100 PSI
0 - 150 PSI
0 - 200 PSI
0 - 300 PSI
0 - 500 PSI
0 - 750 PSI
0 - 1000 PSI
20
30
50
75
100
150
200
300
500
750
1000
Built-in Electrical Connection
A Packard with Mating Connector
B 12”, 18 AWG Leads
C Packard without Mating Connector
Example:
P265-500-S-F-1-A
Description:
P265 Pressure Transmiter, 0-500 PSIS (Sealed Gage), with Ethylene Propylene Seal Material, 1/4 - 18 NPT
Pressure Connection and Mating Connector
Before installation and operation, ensure that the appropriate pressure sensor has been selected in terms of pressure range, design and specific measuring
conditions. Non-compliance can result in serious injury and/or damage to the equipment.
Warning:
The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any
form of contractual commitment. Kavlico reserve the right to modify their products without notice. It is imperative that we should be consulted over any
particular use or application of our products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product
is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any
modification, addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or
substance) which has not been expressly agreed by us prior to the sale of our products.
In an NPN transistor, the base current is only generated by the recombination of electrons diffused from the emitter to the base and holes in the base....
When debugging, I found that the program often ran into the HardFaultException() {while(1);} function! Because K9f1G08 is a large page nand, the defined buffers are both 2k for receiving and sending! ...
[i=s]This post was last edited by littleshrimp on 2020-11-24 10:49[/i]When I was playing with BlueNRG-1 before, although it was convenient to use, I always felt that the 10-bit ADC was not enough. Rec...
At present, the sensors for measuring wind speed mainly adopt thermal, ultrasonic, impeller and pipeline pressure difference methods. The thermal method is that the sensor element generates heat when ...
0 Introduction
With the development of my country's economy, the number of motor vehicles continues to increase. The growth of existing roads and other hardware facilities can no longer meet t...[Details]
Introduction
Power subsystems are becoming more and more integrated into the overall system. Power systems have moved from being separate "essential dangerous devices" to being monitorable...[Details]
In recent years, with the rapid development of the information industry, dot matrix LED display screens have been widely used in various advertising and information display systems such as the fina...[Details]
1. Disadvantages of choosing too high a voltage level
Choosing too high a voltage level will result in too high an investment and a long payback period. As the voltage level increases, the...[Details]
Today, the value of electronic components in cars accounts for 15-20% of the total vehicle. In the future, this proportion may be as high as 30-40% as more safety electronics, fuel consumption and ...[Details]
introduction
At present, measuring instruments are developing towards networking, and each individual embedded instrument will become a node on the Internet. This system realizes the network...[Details]
Key Points
1. Now, in addition to high-end smartphones and tablets, users also expect to use touch screens in other applications, and they are gradually appearing in cars and instruments.
...[Details]
With the continuous advancement of various technologies in the field of measurement and control, the baseband subsystem of general measurement and control equipment has entered the fourth generation o...[Details]
Abstract: Based on the ZigBee parking lot SMS car search system, the location of the vehicle in the parking lot is sent to the owner through SMS, which is convenient for the owner to quickly find ...[Details]
The most important components of new energy electric vehicles are power batteries, electric motors and energy conversion control systems. The power battery must achieve high performance such as fas...[Details]
1. Introduction
Stepper motor is a basic component that converts electrical energy into kinetic energy. It has been widely used in a variety of electromechanical equipment, such as various machine...[Details]
For a long time, my country has implemented "community-style collective heating" for hot water heating, and settled accounts based on the heating area, regardless of whether the user uses heat. Thi...[Details]
High specific energy lithium/thionyl chloride (Li/SOCl2) batteries are widely used in multi-functional intelligent meters (such as smart meters, water meters, etc.) as real-time clocks and memory b...[Details]
With the rapid development of information technology represented by computers, semi-physical simulation technology plays an important role in many military and civilian fields such as aerospace and co...[Details]
1 Theoretical Analysis
Ultrasonic waves
When propagating in a suspension, the ultrasonic waves that encounter the suspended particles are scattered and attenuated at the interface, an...[Details]