Packard Electric Metri-Pack 150 Series, M12 - 4 Pole *
G1/4A DIN 3852-E, G1/4A DIN 3852-A *
304 Stainless Steel (1.4301)
4 - 20 mA, 0.5 - 4.5 VDC, 0 - 5 VDC, 0 - 10 VDC
Attributes
Hermetically Sealed
Rugged & Durable
Compact & Light-weight
Resistant to Chemical Attack
Superior Long-Term Stability & Repeatability
Outstanding Shock & Vibration Performance
Typical Applications
Compressors
Hydraulic Systems
Agricultural Equipment
Construction Equipment
Heat Pumps
Wind Energy
HVAC Systems
Chemical Industry
Description
The PTE5000 utilizes Kavlico’s thin film strain gauge sensing technology, incorporating an hermetically
sealed design with no internal sealing required. Designed for harsh environments, a rugged 304 stainless
steel housing surrounds the PTE5000 transducer.
The PTE5000’s small, compact design as well as its low overall weight makes it ideal
for applications with spacing and weight limitations. This easy-to-use sensor is media
resistant, which allows it to be used for a broad range of liquid and gaseous media. It
can be used at high operating temperatures and has internal temperature compensation.
Highly reliable, the PTE5000 provides accurate, high pressure measurements every time.
www.kavlico.com
Technical Specifications
Pressure Ranges
from 0 to …
Proof pressure
Burst pressure
bar (gage)
bar (gage)
bar (gage)
6
12
60
10
20
100
16
32
160
25
50
200
40
80
320
60
120
480
100
200
600
160
320
960
250
500
1000
400
800
1600
600
1200
2400
Physical
Operating Life Cycle
Vibration Resistance
Shock Resistance
Drop Test
Weight
Ingress Protection
Medium Temperature
Storage Temperature
Media
*4
min. 10 million full pressure cycles over the full range
IEC 60068-2-64 (RANDOM) 20 PSD
25 g minimum according to DIN EN 60068-2-27
1 meter drop on concrete as per SAE J1455 / DIN EN 60068-2-3-1
≤
50 grams (without mating connector)
IP 65 or IP67 - depending on electrical connector
-30°C to + 120°C (others on request)
-30°C to + 100°C (dep. on electrical connector & external seal ring capability)
*4
All class II fluids and gases compatible with stainless steel 304 (1.4301)
Environmental Temperature
-30°C to + 100°C (dep. on electrical connector & external seal ring capability)
*4
For more details see How to Order
Performance
Accuracy
*1
Non-linearity
*2
Non-repeatability
1-year stability
Temp. Coefficients - Zero
Temp. Coefficients - Span
*1
*2
≤
0.5 % of span
*3
0.2 % of span
*3
0.1 % of span
*3
0.2 % of span
*3
0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %
0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %
Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2). Adjusted in vertical mounting position with pressure port down.
BFSL according to IEC 61298-2 reference conditions to EN 61298-1
Others on request
*3
www.kavlico.com
Data Sheet PTE5000
2
Electrical
0.5…4.5 VDC
ratiometric
5 VDC ± 5%
≤
25 mW
min. 6 VDC
Yes
*5
500 VDC
Yes
*6
Output Signal
Operating Supply Signal
Power Consumption
Overvoltage Protection
Short-circuit Proofness
Insulation Voltage
Load
Response Time
*5
4…20 mA
8-30 VDC
≤
600 mW
min. 33 VDC
not applicable
500 VDC
0…5 VDC
8-30 VDC
≤
600 mW
min. 33 VDC
Yes
*5
500 VDC
Yes
*6
≥
4.7 kΩ
0…10 VDC
14-30 VDC
≤
600 mW
min. 33 VDC
Yes
*5
500 VDC
Yes
*6
≥
4.7 kΩ
Reverse Polarity Protection
Yes
*6
≤
(Vsup-8 VDC)/(0.02 A) [Ω]
≥
4.7 kΩ
≤
5 ms max. to 63% of full scale pressure with step change on input
for min. 3 intervals at 5 minutes each
for min. 10 seconds on assigned pins
*6
Approvals & Certificates
Pressure equipment directive 97/23/EC
EMC directive 2004/108/EEC, EN 61 326 Emission (Group 1, Class B)
and Immunity (industrial locations), EMI, ESD protected
Standard(s) for Safety: Electrical Equipment for Measurement, Control and
Laboratory Use - UL 61010-1
2011/65/EU ROHS Directive
CE Compliance
UL
ROHS
www.kavlico.com
Data Sheet PTE5000
3
Dimensions
Pressure Sensor with Electrical Connection
Dimensions in mm [Inch]
M12 Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
Vsup
Vsup
Vsup
Vsup
Pin 2
...
...
...
...
Pin 3
lout
Vout
Vout
Vout
Pin 4
...
GND
GND
GND
18 mm Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
Vsup
Vsup
Vsup
Vsup
Pin 2
lout
Vout
Vout
Vout
Pin 3
...
GND
GND
GND
Pin 4
...
...
...
...
Packard (metri-pack 150) Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
lout
GND
GND
GND
Pin 2
Vsup
Vsup
Vsup
Vsup
Pin 3
...
Vout
Vout
Vout
9.4 mm Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
Vsup
Vsup
Vsup
Vsup
Pin 2
lout
Vout
Vout
Vout
Pin 3
...
GND
GND
GND
Pin 4
...
...
...
...
www.kavlico.com
Data Sheet PTE5000
4
Pressure Connections and Recommended Installation Torque
Everyone is busy, especially office workers. A cup of tea often becomes thick and astringent because you forget to drink it. A cup of instant coffee often gets cold before you remember to drink it. Wh...
For white goods and other home appliance markets: High-performance switching power supply - 28V DC-DC synchronous buck converter : https://training.eeworld.com.cn/course/4219...
1. The difference between AC coupling and DC recovery: In DC coupling, the real measured signal is displayed on the screen. In AC coupling, the input signal is coupled through a capacitor before enter...
Signal integrity analysis is critical at 130nm and below. The impact of crosstalk on latency must be considered, as well as the potential for functional failures due to noise jitter hitting nets that ...
ActiveSync is gone in Vista, and it has become Mobile Device Center. I used to use DEVICETODESKTOP in ADOFILTR to transfer CDB data, but what should I do now?...
introduction
With the continuous optimization of surface mount technology (SMT) and the rapid development of chip component manufacturing technology, the application of chip mounters in the el...[Details]
introduction
my country has a vast territory and a large population. The scale of housing construction is huge, and the amount of residential construction is large and wide. It is still on t...[Details]
1. Introduction
Automobile pollution is one of the most important issues that people are most concerned about and need to solve urgently. As an important method for detecting automobile exhau...[Details]
1. Introduction
Since the 1980s, with the continuous development of automotive electronic technology, there are more and more electronic control units in automobiles, such as electronic fuel i...[Details]
Remote keyless entry (RKE) systems have become popular with users, with more than 80% of new cars in North America and more than 70% in Europe equipped with RKE systems. In addition to the obvious ...[Details]
All electronic design engineers and scientists have performed electrical signal analysis, or signal analysis for short. Through this basic measurement, they can gain insight into signal details and...[Details]
Introduction
Power subsystems are becoming more and more integrated into the overall system. Power systems have moved from being separate "essential dangerous devices" to being monitorable...[Details]
In recent years, lighting has become an important area that countries around the world are targeting to promote energy conservation and environmental protection. According to statistics, about 20% ...[Details]
The data collector of the automatic weather station is generally designed based on a single-chip microcomputer or a PC/104 bus controller. It has the characteristics of good compatibility with PC, low...[Details]
1. Introduction
At present, most lighting equipment still uses traditional energy for lighting. Making full use of solar energy as the energy supply for lighting equipment is of great si...[Details]
1. With the development of modern industry and the continuous improvement of automation, some medium and large control systems have been greatly facilitated, which not only makes control easier, bu...[Details]
Overview:
This paper introduces a method of connecting a CAN-bus network with Ethernet to form a medium-sized remote monitoring/data transmission network.
CAN (Controller Area Network) is ...[Details]
The potentiometer is an adjustable electronic component. The main functions of the potentiometer in the circuit are as follows:
1. Used as a voltage divider
A potentiometer is a continuou...[Details]
Many battery-powered systems require a visual indicator to show when the battery needs to be replaced. LEDs are commonly used for this purpose, but they consume at least 10mA of current. This con...[Details]
Experimental tasks
A DS18B20 is used to form a temperature measurement system. The temperature measurement accuracy reaches 0.1 degrees. The temperature range is between -20 degrees and +50 de...[Details]