www.hammondmfg.com
Climate Control
Cooling Products
General Information .......................................347
Sizing an Air Conditioner ...............................348
Side Mounting DTS Series
1200 BTU/H
NEMA 12 .......................................................349
Side Mounting DTS Series
4000-7500 BTU/H
NEMA 3R, 4, 4X ............................................363
Side Mounting DTS Series
5000-12,000 BTU/H
NEMA 3R, 4, 4X ............................................365
Side Mounting DTS Series
2000 BTU/H
NEMA 12 .......................................................350
Side Mounting DTS Series
14,000-24,000 BTU/H
NEMA 12, 3R, 4, 4X ......................................367
Side Mounting DTS Series
2500 BTU/H
NEMA 12 .......................................................351
Air/Water Heat Exchanger
3241-34,215 BTU/H
NEMA 12, 3R, 4.............................................368
Side Mounting DTS Series
3500-5000 BTU/H
NEMA 12 .......................................................352
Water Chillers
4600-151,000 BTU/H.....................................369
345
Climate Control
Side Mounting DTS Series
4000-7500 BTU/H
NEMA 12 .......................................................353
Air Conditioner Accessories ..........................370
Filterfan
PF 11000-22000
NEMA 12 .......................................................371
Filterfan
PF 3200
NEMA 12 .......................................................373
Filterfan
PF 42500-43000
NEMA 12 .......................................................375
Filterfan
PF 65000, 66000, 67000
NEMA 12 .......................................................377
Top Mount Filterfan
PTF 60500, 60700, 61000
NEMA 12 .......................................................379
Slimline Filterfan
PF 33000, 65000, 67000 SL
NEMA 12 .......................................................381
Filterfan Accessories .....................................382
Side Mounting DTS Series
5000-12,000 BTU/H
NEMA 12 .......................................................355
Top Mounting DTT Series
1700-10,000 BTU/H
NEMA 12 .......................................................357
Side Mounting DTS Series
2500 BTU/H
NEMA 4, 4X ...................................................359
Side Mounting DTS Series
3500 BTU/H
NEMA 3R, 4, 4X ............................................360
Side Mounting DTS Series
4000-7500 BTU/H
NEMA 3R, 4...................................................361
Quality Products. Service Excellence.
© Hammond Manufacturing
Canada: 519.822.2960 or 905.456.3770
USA: 716.630.7030
Data Subject to change without notice
www.hammondmfg.com
Climate Control
PF Filterfans ..................................................383
High Wattage Fan Heater ..............................394
Fan Accessories ............................................385
Filterfan Rainhoods
NEMA 3R.......................................................386
Heaters ..........................................................395
Filtered Fan Boxes and Filter Grills................387
Mini Radiant Heaters .....................................395
Control Panel Heater .....................................396
Blowers and Fans
General Selection Considerations .................389
Filterfan Kits ...................................................389
Thermostat ....................................................397
Fan Kits..........................................................390
Twin Thermostats ..........................................398
Climate Control
AC Fans and Guards .....................................390
Mechanical Humidistat ..................................399
Fan Tray -
300, 600 and 900 CFM ..................................391
Electronic Humidity and
Temperature Control ......................................399
Packaged Twin Blowers .................................392
Fan Panel Assembly ......................................392
Breather Kits
Pressure Compensation Plug ........................400
Heating Products
General Selection Considerations .................393
Fan Heater with Thermostat ..........................393
Rainproof Ventilators .....................................401
Fan Heaters ...................................................394
Louvered Vent Kits .........................................402
Quality Products. Service Excellence.
© Hammond Manufacturing
Canada: 519.822.2960 or 905.456.3770
USA: 716.630.7030
Data Subject to change without notice
346
www.hammondmfg.com
Cooling Products
General Information
The Need for Environment Control
With wide spread use of micro-electronics in today’s control systems, temperature management takes on a new priority in
order to ensure steady and reliable performance. The maintenance of a correct operating temperature may combine both
cooling and/ or heating inside an enclosure which can protect against costly down time and system failures.
General Selection Considerations
Cooling
Conditions
Maximum desired enclosure
temperature is 10°F or 5°C
above maximum outside ambient.
Solution
Advantages
Oversize the enclosure. Easy to implement, no maintenance.
Maintains NEMA rating of the
enclosure.
Install ventilation
Economical solution, very little
louvers.
maintenance, easy to implement.
Install filter fans.
Less expensive than air/refrigeration
systems. Relatively high amount of
heat removed, some termperature
control by using thermostats.
Easy to install, small power
consumption, temperature control via
thermostat. Maintains NEMA rating of
the enclosure.
Easy to install. Temperature control
via factory installed thermostat.
Removes large amounts of heat.
Maintains NEMA rating of enclosure,
dehumidifies enclosure air.
Disadvantages
Dissipates small amount of heat.
Larger enclosure size takes up more
space.
Dissipates limited amount of heat.
Dirt, oil or fluids could enter the
enclosure. NEMA rating is affected.
Must maintain filters. NEMA rating
can be affected. Limited use in hostile
environments such as chemical
applications.
Must maintain filters.
Use an air/air heat
exchanger.
347
Climate Control
Maximum desired enclosure
temperature lower than
maximum outside ambient.
Use an air conditioner.
Must maintain filter. Generally not to
be used when outside temperature
is below 59°F (15°) or above 130°F
(52°C).
Circulation
Conditions
Localized heat or 'hot spots'.
Solution
Install circulation fans
in the enclosure.
Advantages
Economical solution, no maintenance,
easy to install. Maintains NEMA rating
of the enclosure.
Disadvantages
Dissipates small amount of heat.
Heating
Conditions
Outside temperature is below
minimum allowable equipment
operation range.
Condensation occurs.
Solution
Heat with radiant
heater.
Heat with radiant
heater to maintain
temperature above
the dewpoint.
Advantages
Economical power consumption.
Reliable, can be temperature
controlled.
Economical power consumption.
Reliable, humidity can be controlled.
Disadvantages
Consumes energy, takes up internal
panel space.
Consumes energy, takes up internal
panel space.
Technical references and CAD downloads available at www.hammondmfg.com
All dimensions in inches unless specified otherwise
Quality Products. Service Excellence.
© Hammond Manufacturing
Canada: 519.822.2960 or 905.456.3770
USA: 716.630.7030
Data Subject to change without notice
www.hammondmfg.com
Cooling Products
Sizing an Air Conditioner
Sizing an Air Conditioner
The proper selection of an air conditioner is determined by the following steps:
Step 1)
Step 2)
Step 3)
Step 4)
Internal heat load quoted as Watts that must be dissipated.
The exposed surface area of the enclosure.
Temperature differential required between maximum inside temperature and maximum outside ambient.
Final calculation of the above.
Climate Control
1 Watt = 3.413 BTU/H
Determine the internal heat load
(in Watts) that must be dissipated.
1 m
2
= 10.76 ft
2
Calculate the exposed surface
area of the enclosure:
2(h" x w") + 2(h" x d") + (w" x d")
144
(Example for freestanding enclosure)
=Area (ft
2
)
1°C or 1°K T=1.8°F T
Determine the temperature differential
by subtracting the maximum allowable
temperature inside the enclosure (T
i
)
from the maximum ambient temperature
outside the enclosure (T
o
).
T
o
-T
i
= DT
Step Four
(Watts x 3.413)
+
[1.25 x Area ft
2
x
DT (°F)] = BTU/H
Capacity Required
BTU/H. Capacity Rating.
The DTS/DTT offering is available in the most popular selection of cooling capacities, sizes, voltages and mounting configurations. Available
capacities range from 1,200 to 24,000 BTU/H in both side mounting and top mounting models. All models use powerful radial fans for maximum
air circulation inside the enclosure in ambient temperatures of 125°F (+52°C). Models from 2,000 BTU/H capacity are equipped with thermal
expansion valves for optimal use of the evaporator heat exchange surface under all operating conditions. For additional protection of the
compressor motor, these valves are supplied as standard with Maximum Operating Pressure control devices (MOP). For energy conservation,
the use of hot gas bypass valves is limited to the unloaded starting and control of large compressors from 8,000 BTU/H upwards. All air
conditioners were developed, designed and subject to final inspections in accordance with international standards.
Technical references and CAD downloads available at www.hammondmfg.com
All dimensions in inches unless specified otherwise
Quality Products. Service Excellence.
© Hammond Manufacturing
Canada: 519.822.2960 or 905.456.3770
USA: 716.630.7030
Data Subject to change without notice
348
www.hammondmfg.com
Side Mounting DTS Series
1200 BTU/H
Description
• Designed for side mounting where
hot spot cooling or low capacity
cooling is required.
• Compact design uses minimal
surface area.
• Closed loop cooling ensures air is
recirculated without ever mixing with
contaminated ambient air.
Standards
• Maintains NEMA 12 rating
• IP 54
• UR, cUR and CE
• EMI/RFI suppression meets CE.
• Line cord with plug (115 V).
• Washable filter mat protected within
an easily removable grill.
• Gasket, mounting kit and template
for enclosure cutout and drilling are
included.
• Condensate drain hose and clamp
provided.
• Exterior case easily removable for
field service.
• Q Mount allows unit to hang in
place for easy installation.
Accessories
• Gaskets
...see page
456
Features
• R134a refrigerant.
• Thermostat control.
• Continuous air circulation from high
capacity fans.
349
Climate Control
Part Number
DTS1200A115LG
DTS1200A230LG
Ship Wt. lbs
42
42
Technical Data
Electrical Data
Rated Voltage
Range of Operation
Power Consumption
Running Amps
Starting Current
Line Cord
DTS1200A115LG
115 V 60 Hz
110 V 50 Hz
103-127 V
200 W
2.2 A
15.7 A
With plug
DTS1200A230LG
230 V 50/60 Hz
207-253 V
200 W
1.3 A
9.5 A
Without plug
1,200 BTU/H (350 Watts)
R134a
+77…+131 F / +25…+45 C
Factory Setting +95 F (+35 C)
Max. Ambient Air Temp.
+125°F (+52°C)
Min. Ambient Air Temp.
+46°F (+8°C)
Air Capacity (unrestricted) Internal Circulation 106 CFM
External Circulation 230 CFM
Condensate Discharge
Direct via tube
Filter Mat
150 g/m²
<
62 dB(A)
Db Noise Level
Unit Weight
40 lbs (18 kg)
Exterior Case
Galvanized sheet steel
Finish
RAL7035 light grey finish
NEMA Rating
Enclosures IP 54/NEMA 12
All dimensions in inches unless specified otherwise
Refrigeration Data
Rated Capacity
Type of Refrigerant
Adjustable Control Range
Technical references and CAD downloads available at www.hammondmfg.com
Quality Products. Service Excellence.
© Hammond Manufacturing
Canada: 519.822.2960 or 905.456.3770
USA: 716.630.7030
Data Subject to change without notice