Bulletin PD-2.307 rev. B 12/01
40CPQ035
40CPQ040
40CPQ045
SCHOTTKY RECTIFIER
40 Amp
Major Ratings and Characteristics
Characteristics
I
F(AV)
Rectangular
waveform
V
RRM
I
FSM
@ tp = 5 µs sine
V
F
T
J
@ 20 Apk, T
J
=125°C
(per leg)
Description/Features
Units
A
V
A
V
The 40CPQ... center tap Schottky rectifier has been optimized
for very low forward voltage drop, with moderate leakage. The
proprietary barrier technology allows for reliable operation up
to 150° C junction temperature. Typical applications are in
switching power supplies, converters, free-wheeling diodes,
and reverse battery protection.
150° C T
J
operation
Center tap TO-247 package
High purity, high temperature epoxy encapsulation for
enhanced mechanical strength and moisture resistance
Very low forward voltage drop
High frequency operation
Guard ring for enhanced ruggedness and long term
reliability
40CPQ...
40
35/40/45
3500
0.43
- 55 to 150
°C
Case Styles
40CPQ045
Base
Common
Cathode
2
1
3
2
Anode
1
Anode
2
Common
Cathode
TO-247AC
www.irf.com
1
40CPQ035, 40CPQ040, 40CPQ045
Bulletin PD-2.307 rev. B 12/01
Voltage Ratings
Part number
V
R
Max. DC Reverse Voltage (V)
V
RWM
Max. Working Peak Reverse Voltage (V)
40CPQ035
35
40CPQ040
40
40CPQ045
45
Absolute Maximum Ratings
Parameters
I
F(AV)
Max. Average Forward Current
* See Fig. 5
I
FSM
E
AS
I
AR
Max. Peak One Cycle Non-Repetitive
Surge Current (Per Leg) * See Fig. 7
Non-Repetitive Avalanche Energy
(Per Leg)
Repetitive Avalanche Current
(Per Leg)
3500
430
27
4
A
mJ
A
5µs Sine or 3µs Rect. pulse
Following any rated
load condition and with
10ms Sine or 6ms Rect. pulse rated V
RRM
applied
40CPQ... Units
40
A
Conditions
50% duty cycle @ T
C
= 120 °C, rectangular wave form
T
J
= 25 °C, I
AS
= 4 Amps, L = 3.4 mH
Current decaying linearly to zero in 1 µsec
Frequency limited by T
J
max. V
A
= 1.5 x V
R
typical
Electrical Specifications
Parameters
V
FM
Max. Forward Voltage Drop
(Per Leg) * See Fig. 1
(1)
40CPQ... Units
0.49
0.59
0.43
0.56
4
150
1850
7.5
10000
V
V
V
V
mA
mA
pF
nH
V/ µs
@ 20A
@ 40A
@ 20A
@ 40A
Conditions
T
J
= 25 °C
T
J
= 125 °C
V
R
= rated V
R
I
RM
C
T
L
S
Max. Reverse Leakage Current
(Per Leg) * See Fig. 2
(1)
Max. Junction Capacitance (Per Leg)
Typical Series Inductance (Per Leg)
T
J
= 25 °C
T
J
= 125 °C
V
R
= 5V
DC
, (test signal range 100Khz to 1Mhz) 25°C
Measured lead to lead 5mm from package body
dv/dt Max. Voltage Rate of Change
(Rated V
R
)
(1) Pulse Width < 300µs, Duty Cycle <2%
Thermal-Mechanical Specifications
Parameters
T
J
T
stg
Max. Junction Temperature Range
Max. Storage Temperature Range
40CPQ... Units
-55 to 150
-55 to 150
1.25
0.63
0.24
6 (0.21)
Min.
Max.
6 (5)
12 (10)
°C
°C
Conditions
R
thJC
Max. Thermal Resistance Junction
to Case (Per Leg)
R
thJC
Max. Thermal Resistance Junction
to Case (Per Package)
R
thCS
Typical Thermal Resistance, Case
to Heatsink
wt
T
Approximate Weight
Mounting Torque
Case Style
°C/W DC operation
°C/W DC operation
* See Fig. 4
°C/W Mounting surface , smooth and greased
g (oz.)
Kg-cm Non-lubricated threads
(Ibf-in)
TO-247AC(TO-3P) JEDEC
2
www.irf.com
40CPQ035, 40CPQ040, 40CPQ045
Bulletin PD-2.307 rev. B 12/01
10
00
10
00
10
0
R v rs C rr n - I (m )
ee e u et
A
R
1
0
1
.1
.0
1
.0 1
0
0
T =1 0 C
5°
J
1 5C
2°
1 0C
0°
7°
5C
5°
0C
2°
5C
10
0
In ta ta e u F rw rdC rre t - I (A
s n nos o a
u n
)
F
5
1 1 2 2 3 3 4 4
0 5 0 5 0 5 0 5
R v rs V lta e- V (V
ee e o g
R )
1
0
T =1 0 C
5°
J
J n tio C p c n e- C (p )
u c n a a ita c
F
T
T =1 5 C
2°
J
T= 2°
5C
J
1
Fig. 2 - Typical Values Of Reverse Current
Vs. Reverse Voltage (Per Leg)
100
00
T =2 °
5C
J
10
00
.1
0
.2
.4
.6
.8
1
1
.2
1
.4
10
0
0
1
0
2
0
3
0
4
0
5
0
F rw rdV lta eD p- V (V
o a
o g ro
)
F
M
R v rs V lta e- V (V
ee e o g
R )
Fig. 1 - Max. Forward Voltage Drop Characteristics
(Per Leg)
1
0
T em l Im e a c - Zth C (° /W
hr a pd ne
C )
J
Fig. 3 - Typical Junction Capacitance
Vs. Reverse Voltage (Per Leg)
1
.1
D=0 0
.5
D=0 3
.3
D=0 5
.2
D=0 7
.1
D=0 8
.0
P
M
D
t
1
t2
N te :
o s
1 D tyfa to D= t1/ t2
. u
c r
.0
1
S g P ls
in le u e
(T e a R s ta c )
h rm l e is n e
.0 1
0
.0 0 1
00
.0 0
01
.0 1
0
.0
1
.1
2 P a T =P xZ
. ek
+T
J D
M th C C
J
1
1
0
10
0
t , R c n u r P ls D ra n(S c n s
e ta g la u e u tio
eod)
1
Fig. 4 - Max. Thermal Impedance Z
thJC
Characteristics (Per Leg)
www.irf.com
3
40CPQ035, 40CPQ040, 40CPQ045
Bulletin PD-2.307 rev. B 12/01
15
5
A w b C s T m e tu - (° )
llo a le a e e p ra re C
R J (D ) =1 5 C
.2 ° /W
th C C
1
4
D=0 8
.0
D=0 7
.1
1
2
D=0 5
.2
D=0 3
.3
1
0
D=0 0
.5
8
6
4
2
0
0
R SL it
M im
D
C
10
5
15
4
10
4
D
C
15
3
10
3
0
A e g P w r L s - (W tts
v ra e o e o s
a )
5
1
0
1
5
2
0
2
5
3
0
5
1
0
1
5
2
0
2
5
3
0
A e g F rw rdC rre t - IF V (A
v ra e o a
u n
(A ) )
A e g F rw rdC rre t - I
v ra e o a
u n
(A
)
F V
(A )
Fig. 5 - Max. Allowable Case Temperature
Vs. Average Forward Current (Per Leg)
10000
(A)
Fig. 6 - Forward Power Loss Characteristics
(Per Leg)
Non-Repetitive Surge Current - I
FSM
1000
At Any Rated Load Condition
And With Rated V
RRM
Applied
Following Surge
100
10
100
1000
10000
Square Wave Pulse Duration - t
p
(microsec)
Fig. 7 - Max. Non-Repetitive Surge Current (Per Leg)
L
H IG H-SPE ED
SW ITC H
FR EE-W H E EL
D IO D E
40H FL40 S02
V d = 25 V olt
D UT
IRFP460
Rg = 25 ohm
+
C URRE NT
M O N ITO R
Fig. 8 - Unclamped Inductive Test Circuit
4
www.irf.com
40CPQ035, 40CPQ040, 40CPQ045
Bulletin PD-2.307 rev. B 12/01
Outline Table
3.65 (0.144)
3.55 (0.139)
5.70 (0.225)
5.30 (0.208)
20.30 (0.800)
19.70 (0.775)
1
14.80 (0.583)
14.20 (0.559)
2
3
5.50 (0.217)
4.50 (0.177)
(2 PLCS.)
1
3
2
15.90 (0.626)
15.30 (0.602)
DIA.
5.30 (0.209)
4.70 (0.185)
2.5 (0.098)
1.5 (0.059)
Base
Common
Cathode
2
Anode
1
Anode
2
4.30 (0.170)
3.70 (0.145)
2.20 (0.087)
MAX.
3.20 (0.126)
MAX.
0.80 (0.032)
0.40 (0.213)
2.40 (0.095)
MAX.
Common
Cathode
1.40 (0.056)
1.00 (0.039)
5.47 (0.216)
5.43 (0.213)
Conform to JEDEC outline TO-247AC (TO-3P)
Dimensions in millimeters and (inches)
Marking Information
THIS IS A 40CPQ045
WITH LOT CODE 58 07
ASSEMBLED ON WW 21, 2000
IN THE ASSEMBLY LINE "L"
INTERNATIONAL
RECTIFIER
LOGO
ASSEMBLY
LOT CODE
PART NUMBER
40CPQ045
035H
58
07
DATE CODE
YEAR 0 = 2000
WEEK 35
LINE H
www.irf.com
5