EEWORLDEEWORLDEEWORLD

Part Number

Search

D38999-26GH32AD

CategoryThe connector   
File Size273KB,2 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

D38999-26GH32AD Online Shopping

Suppliers Part Number Price MOQ In stock  
D38999-26GH32AD - - View Buy Now

D38999-26GH32AD Parametric

Parameter NameAttribute value
Product CategoryCircular MIL Spec Connector
ManufacturerGlenair
Factory Pack Quantity1
COTS EQUIVALENT
MIL-DTL-38999 Series III Environmental connectors
233-105 Crimp contact series with accessory threads
How To Order - 233-105
Sample Part Number
Series / Basic Part No.
Connector Style
Material and Finish
233-105
MIL-DTL-38999 Series III Environmental Connector
20
= Wall mount receptacle
24
= Jam nut receptacle
26
= Plug
See Table I
-20
NF
17-8
P
N
-LC
Shell Size-Insert Arrangement
Per MIL-STD-1560
Contact Type
Alternate Polarization
Mod Code for Less Contacts
P
= Pin, 500 cycles
A
= Pin insert, less standard contacts
A, B, C, D, E, N
= Normal
Connector marked with
P
or
S
according to insert but supplied less contacts
S
= Socket, 500 cycles
B
= Socket insert, less standard contacts
Table I: Material and Finish
38999
F
G
T
W
Z*
233-105
ME
MA
MT
NF
ZR
Aluminum
Material
Finish Description
Electroless nickel (48 hr. salt spray)
Space-grade electroless nickel, matte (48 hr. salt spray)
Ni-PTFE
Cadmium O.D. over electroless nickel (500 hr. salt spray)
Black zinc-nickel over electroless nickel
RoHS
½
*qualification pending
Connector Mating and Accessory Thread Dimensions
Shell
Size
Code
A
B
C
D
E
F
G
H
J
Shell
Size
9
11
13
15
17
19
21
23
25
A Thread
.6250-.1P-.3L-TS-2A
.7500-.1P-.3L-TS-2A
.8750-.1P-.3L-TS-2A
1.0000-.1P-.3L-TS-2A
1.1875-.1P-.3L-TS-2A
1.2500-.1P-.3L-TS-2A
1.3750-.1P-.3L-TS-2A
1.5000-.1P-.3L-TS-2A
1.6250-.1P-.3L-TS-2A
J Thread
M12 X 1.0-6g 0.100R
M15 X 1.0-6g 0.100R
M18 X 1.0-6g 0.100R
M22 X 1.0-6g 0.100R
M25 X 1.0-6g 0.100R
M28 X 1.0-6g 0.100R
M31 X 1.0-6g 0.100R
M34 X 1.0-6g 0.100R
M37 X 1.0-6g 0.100R
Wire Accommodation
Contact Size
23
22D
20
16
12
Wire Gauge
#22 - #28
#22 - #28
#20 - #24
#16 - #20
#12 - #14
NOTES
1. 233-105 is designed to meet or exceed the mechanical,
electrical, environmental and dimensional requirements of
D38999/20, /24 & /26.
2. Insert arrangements IAW MIL-STD-1560, Glenair HD and size #8
shielded contact insert arrangements available only in COTS
series
12
3. Blue color band indicates rear release retention system.
4. Connector is supplied with contacts (including spares),
insertion/removal tool and sealing plugs.
5. Dimensions in inches (millimeters) are subject to change
without notice
6. Consult factory for additional information
© 2016 Glenair, Inc • 1211 Air Way, Glendale, CA 91201 • 818-247-6000 • www.glenair.com • U.S. CAGE code 06324 • MIL-DTL-38999 Series III brochure
Dimensions in inches (millimeters) are subject to change without notice
M4 assembly instruction problem
Is there any expert who is familiar with M4 assembly instructions? I encountered an error while writing an assembly code. The following is an assembly code for processing SVC call numbers. It is still...
jplzl10000 ARM Technology
Credit Suisse report: Russia's wealth gap is the largest in the world, and Chinese family wealth continues to grow
On the 9th, the Swiss-based Credit Suisse Research Institute released its fourth annual Global Wealth Report. The report said that since 2000, China's per capita wealth has almost quadrupled, from $5,...
walkwk Talking
Do I need to solder the capacitor next to the external 32768 crystal oscillator of MSP-EXP430G2?
When I was learning about the MSP-EXP430G2 board, TI gave me a 32768 crystal oscillator. I wanted to solder it on, but I saw that there were positions for two 12pf capacitors on the circuit, but TI di...
lkl0305 Microcontroller MCU
Why is the triangle wave sampled by my AD like this? It doesn't specify what the unit of the vertical axis is.
Why is the triangle wave sampled by my AD like this? It doesn't specify what the unit of the vertical axis is....
双子charming1 DSP and ARM Processors
Key points of transformer design
Key points of transformer design (1) Both the pulse source and the load are field effect tubes, and their input capacitance is relatively large. Usually, the magnetic reset is accelerated by reducing ...
zbz0529 Power technology
PCB LAYOUT Technology Encyclopedia
1. Common errors in schematics: (1) ERC reports that the pin is not connected to the signal: a. The I/O attribute is defined for the pin when creating the package; b. The inconsistent grid attribute i...
kandy2059 PCB Design

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 676  1746  600  807  177  14  36  13  17  4 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号