IllumInatIon
luXEon CoB Core Range (Gen 2)
Uniform, high-efficacy and easy-to-design array
The second generation of LUXEON CoB represents a new breakthrough
in efficacy for arrays. It has 10% higher efficiency and 10% higher lumen
output at the same drive currents compared to existing LUXEON CoB.
Due to its small Light Emitting Surface (LES), LUXEON CoB LEDs are
easy to work with and enable less expensive designs due to its industry-
leading lower thermal resistance. LUXEON CoB are hot-tested at 85°C
and available in 3-step MacAdam ellipse, ensuring uniform optical
performance in a wide range of applications.
FEatuREs and BEnEFIts
Highest flux densities with industry’s smallest LES
3-step MacAdam ellipse color definition:
Freedom from Binning
for color
consistency from luminaire to luminaire
Up to 4x lower thermal resistance than competition, enabling smaller heat
sinks and higher lumens
Supported by a comprehensive optical, mechanical and electrical ecosystem
PRImaRy aPPlICatIons
Architectural
Downlights
High Bay & Low Bay
Lamps
Outdoor
Specialty Lighting
Spotlights
PB155 LUXEON CoB Core Range (Gen 2) Product Brief ©2016 Lumileds Holding B.V. All rights reserved.
1
LUXEON CoB Core Range (Gen 2) product performance at specified test current, T
j
=85ºC.
PRoduCt
nomInal
CCt
2200K
2700K
3000K
3500K
4000K
5000K
5700K
LUXEON
CoB
1202s
2200K
2200K
2700K
2700K
3000K
3000K
3500K
3500K
4000K
4000K
3000K
3500K
4000K
5000K
5700K
2200K
2700K
LUXEON
CoB
1202
3000K
3500K
4000K
5000K
5700K
2200K
2700K
3000K
3500K
4000K
mInImum
CRI
[1, 2, 3]
80
80
80
80
80
80
80
90
90
[4]
90
90
[4]
90
90
[4]
90
90
[4]
90
90
[4]
70
70
70
70
70
80
80
80
80
80
80
80
90
90
90
90
90
lumInous FluX
[1]
(lm)
mInImum
660
756
788
828
844
860
828
573
539
661
609
675
637
708
662
720
700
924
924
982
982
941
658
791
833
866
895
899
859
599
691
716
740
774
tyPICal
733
840
875
920
938
956
920
636
599
734
677
750
708
786
735
800
778
1027
1027
1092
1092
1045
731
879
925
962
994
999
955
666
768
796
822
860
tyPICal
lumInous
EFFICaCy (lm/W)
105
120
125
131
134
137
131
91
86
105
97
107
101
112
105
114
111
147
147
152
152
149
104
126
132
137
142
143
134
95
110
114
118
123
tEst
CuRREnt
(ma)
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
lEs
(mm)
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
PaRt numBER
L2C2-22801202E0600
L2C2-27801202E0600
L2C2-30801202E0600
L2C2-35801202E0600
L2C2-40801202E0600
L2C2-50801202E0600
L2C2-57801202E0600
L2C2-22901202E0600
L2C2-22951202E0600
L2C2-27901202E0600
L2C2-27951202E0600
L2C2-30901202E0600
L2C2-30951202E0600
L2C2-35901202E0600
L2C2-35951202E0600
L2C2-40901202E0600
L2C2-40951202E0600
L2C2-30701202E0900
L2C2-35701202E0900
L2C2-40701202E0900
L2C2-50701202E0900
L2C2-57701202E0900
L2C2-22801202E0900
L2C2-27801202E0900
L2C2-30801202E0900
L2C2-35801202E0900
L2C2-40801202E0900
L2C2-50801202E0900
L2C2-57801202E0900
L2C2-22901202E0900
L2C2-27901202E0900
L2C2-30901202E0900
L2C2-35901202E0900
L2C2-40901202E0900
Notes:
1.
Lumileds maintains a tolerance of ±2 on CRI and ±6.5% on luminous flux measurements.
2.
Typical CRI is approximately 2 points higher than the minimum CRI specified, but this is not guaranteed.
3.
R9 value of 90CRI products is >5
4.
Typical CRI is 97.
PB155 LUXEON CoB Core Range (Gen 2) Product Brief 20161106 ©2016 Lumileds Holding B.V. All rights reserved.
2
LUXEON CoB Core Range (Gen 2) product performance at specified test current, T
j
=85ºC (continued).
PRoduCt
nomInal
CCt
3000K
3500K
4000K
5000K
5700K
2200K
2700K
LUXEON
CoB
1203
3000K
3500K
4000K
5000K
5700K
2200K
2700K
3000K
3500K
4000K
3000K
3500K
4000K
5000K
5700K
2200K
2700K
LUXEON
CoB
1204
3000K
3500K
4000K
5000K
5700K
2200K
2700K
3000K
3500K
4000K
mInImum
CRI
[1, 2, 3]
70
70
70
70
70
80
80
80
80
80
80
80
90
90
90
90
90
70
70
70
70
70
80
80
80
80
80
80
80
90
90
90
90
90
lumInous FluX
[1]
(lm)
mInImum
1332
1332
1416
1416
1356
948
1140
1200
1248
1290
1296
1264
864
996
1032
1067
1116
1998
1998
2124
2124
2034
1422
1710
1800
1872
1935
1944
1971
1296
1494
1548
1600
1674
tyPICal
1499
1499
1593
1593
1526
1067
1283
1350
1404
1451
1458
1404
972
1121
1161
1200
1256
2248
2248
2390
2390
2288
1600
1924
2025
2106
2177
2187
2190
1458
1681
1742
1800
1883
tyPICal
lumInous
EFFICaCy (lm/W)
143
143
148
148
145
102
122
129
134
138
139
134
93
107
111
114
120
143
143
148
148
145
102
122
129
134
138
139
134
93
107
111
114
120
tEst
CuRREnt
(ma)
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
lEs
(mm)
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
PaRt numBER
L2C2-30701203E0900
L2C2-35701203E0900
L2C2-40701203E0900
L2C2-50701203E0900
L2C2-57701203E0900
L2C2-22801203E0900
L2C2-27801203E0900
L2C2-30801203E0900
L2C2-35801203E0900
L2C2-40801203E0900
L2C2-50801203E0900
L2C2-57801203E0900
L2C2-22901203E0900
L2C2-27901203E0900
L2C2-30901203E0900
L2C2-35901203E0900
L2C2-40901203E0900
L2C2-30701204E1300
L2C2-35701204E1300
L2C2-40701204E1300
L2C2-50701204E1300
L2C2-57701204E1300
L2C2-22801204E1300
L2C2-27801204E1300
L2C2-30801204E1300
L2C2-35801204E1300
L2C2-40801204E1300
L2C2-50801204E1300
L2C2-57801204E1300
L2C2-22901204E1300
L2C2-27901204E1300
L2C2-30901204E1300
L2C2-35901204E1300
L2C2-40901204E1300
Notes:
1.
Lumileds maintains a tolerance of ±2 on CRI and ±6.5% on luminous flux measurements.
2.
Typical CRI is approximately 2 points higher than the minimum CRI specified, but this is not guaranteed.
3.
R9 value of 90CRI products is >50.
PB155 LUXEON CoB Core Range (Gen 2) Product Brief 20161106 ©2016 Lumileds Holding B.V. All rights reserved.
3
LUXEON CoB Core Range (Gen 2) product performance at specified test current, T
j
=85ºC (continued).
PRoduCt
nomInal
CCt
3000K
3500K
4000K
5000K
5700K
2200K
2700K
LUXEON
CoB
1205
3000K
3500K
4000K
5000K
5700K
2200K
2700K
3000K
3500K
4000K
3000K
3500K
4000K
5000K
5700K
2200K
2700K
LUXEON
CoB
1208
3000K
3500K
4000K
5000K
5700K
2200K
2700K
3000K
3500K
4000K
mInImum
CRI
[1, 2, 3]
70
70
70
70
70
80
80
80
80
80
80
80
90
90
90
90
90
70
70
70
70
70
80
80
80
80
80
80
80
90
90
90
90
90
lumInous FluX
[1]
(lm)
mInImum
2720
2720
2891
2891
2769
1936
2328
2450
2548
2634
2646
2527
1764
2034
2107
2178
2279
4024
4024
4278
4278
4096
2864
3444
3625
3770
3897
3915
3791
2610
3009
3118
3223
3371
tyPICal
2997
2997
3186
3186
3051
2133
2565
2700
2808
2903
2916
2808
1944
2241
2322
2400
2511
4496
4496
4779
4779
4577
3200
3848
4050
4212
4354
4374
4212
2916
3362
3483
3600
3767
tyPICal
lumInous
EFFICaCy (lm/W)
143
143
148
148
145
102
122
129
134
138
139
134
93
107
111
114
120
143
143
148
148
145
102
122
129
134
138
139
134
93
107
111
114
120
tEst
CuRREnt
(ma)
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
900
900
900
900
900
900
900
900
900
900
900
900
900
900
900
900
900
lEs
(mm)
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
PaRt numBER
L2C2-30701205E1300
L2C2-35701205E1300
L2C2-40701205E1300
L2C2-50701205E1300
L2C2-57701205E1300
L2C2-22801205E1300
L2C2-27801205E1300
L2C2-30801205E1300
L2C2-35801205E1300
L2C2-40801205E1300
L2C2-50801205E1300
L2C2-57801205E1300
L2C2-22901205E1300
L2C2-27901205E1300
L2C2-30901205E1300
L2C2-35901205E1300
L2C2-40901205E1300
L2C2-30701208E1500
L2C2-35701208E1500
L2C2-40701208E1500
L2C2-50701208E1500
L2C2-57701208E1500
L2C2-22801208E1500
L2C2-27801208E1500
L2C2-30801208E1500
L2C2-35801208E1500
L2C2-40801208E1500
L2C2-50801208E1500
L2C2-57801208E1500
L2C2-22901208E1500
L2C2-27901208E1500
L2C2-30901208E1500
L2C2-35901208E1500
L2C2-40901208E1500
Notes:
1.
Lumileds maintains a tolerance of ±2 on CRI and ±6.5% on luminous flux measurements.
2.
Typical CRI is approximately 2 points higher than the minimum CRI specified, but this is not guaranteed.
3.
R9 value of 90CRI products is >50.
PB155 LUXEON CoB Core Range (Gen 2) Product Brief 20161106 ©2016 Lumileds Holding B.V. All rights reserved.
4
LUXEON CoB Core Range (Gen 2) product performance at specified test current, T
j
=85ºC (continued).
PRoduCt
nomInal
CCt
3000K
3500K
4000K
5000K
5700K
2200K
2700K
LUXEON
CoB
1211
3000K
3500K
4000K
5000K
5700K
2200K
2700K
3000K
3500K
4000K
3000K
3500K
4000K
5000K
5700K
2200K
2700K
LUXEON
CoB
1216
3000K
3500K
4000K
5000K
5700K
2200K
2700K
3000K
3500K
4000K
mInImum
CRI
[1, 2, 3]
70
70
70
70
70
80
80
80
80
80
80
80
90
90
90
90
90
70
70
70
70
70
80
80
80
80
80
80
80
90
90
90
90
90
lumInous FluX
[1]
(lm)
mInImum
5550
5550
5900
5900
5650
3950
4750
5000
5200
5375
5400
5054
3600
4150
4300
4445
4650
7229
7229
7684
7684
7359
5144
6187
6512
6773
7002
7034
6773
4689
5405
5601
5790
6056
tyPICal
5994
5994
6372
6372
6102
4266
5130
5400
5616
5805
5832
5616
3888
4482
4644
4801
5022
8032
8032
8538
8538
8177
5716
6874
7236
7525
7780
7815
7525
5210
6006
6223
6433
6729
tyPICal
lumInous
EFFICaCy (lm/W)
143
143
148
148
145
102
122
129
134
138
139
134
93
107
111
114
120
143
143
152
152
146
102
123
129
134
139
140
134
93
107
111
115
120
tEst
CuRREnt
(ma)
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
lEs
(mm)
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
PaRt numBER
L2C2-30701211E1900
L2C2-35701211E1900
L2C2-40701211E1900
L2C2-50701211E1900
L2C2-57701211E1900
L2C2-22801211E1900
L2C2-27801211E1900
L2C2-30801211E1900
L2C2-35801211E1900
L2C2-40801211E1900
L2C2-50801211E1900
L2C2-57801211E1900
L2C2-22901211E1900
L2C2-27901211E1900
L2C2-30901211E1900
L2C2-35901211E1900
L2C2-40901211E1900
L2C2-30701216E2300
L2C2-35701216E2300
L2C2-40701216E2300
L2C2-50701216E2300
L2C2-57701216E2300
L2C2-22801216E2300
L2C2-27801216E2300
L2C2-30801216E2300
L2C2-35801216E2300
L2C2-40801216E2300
L2C2-50801216E2300
L2C2-57801216E2300
L2C2-22901216E2300
L2C2-27901216E2300
L2C2-30901216E2300
L2C2-35901216E2300
L2C2-40901216E2300
Notes:
1.
Lumileds maintains a tolerance of ±2 on CRI and ±6.5% on luminous flux measurements.
2.
Typical CRI is approximately 2 points higher than the minimum CRI specified, but this is not guaranteed.
3.
R9 value of 90CRI products is >50.
©2016 Lumileds Holding B.V. All rights reserved.
LUXEON is a registered trademark of the Lumileds Holding B.V.
in the United States and other countries.
lumileds.com
Lumileds Holding B.V. shall not be liable for any kind of loss of data or any other damages, direct,
indirect or consequential, resulting from the use of the provided information and data. Although
Lumileds Holding B.V. has attempted to provide the most accurate information and data, the
materials and services information and data are provided “as is” and Lumileds Holding B.V.
neither warranties, nor guarantees the contents and correctness of the provided information
and data. Lumileds Holding B.V. reserves the right to make changes without notice. You as user
agree to this disclaimer and user agreement with the download or use of the provided materials,
information and data.
PB155 LUXEON CoB Core Range (Gen 2)
Product Brief 20161106