EEWORLDEEWORLDEEWORLD

Part Number

Search

FN9226-3-02

Description
8-bit Microcontrollers - MCU 96KB FL 3328bytes RAM 36I/O
CategoryThe connector    The connector   
File Size233KB,4 Pages
ManufacturerSchaffner
Environmental Compliance
Download Datasheet Parametric Compare View All

FN9226-3-02 Online Shopping

Suppliers Part Number Price MOQ In stock  
FN9226-3-02 - - View Buy Now

FN9226-3-02 Overview

8-bit Microcontrollers - MCU 96KB FL 3328bytes RAM 36I/O

FN9226-3-02 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSchaffner
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSTANDARDS: IEC 60939; CSA 22.2; UL 94V-2
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings3A, 250VAC
Installation typeBOARD AND PANEL
OptionsGENERAL PURPOSE
Termination typeSOLDER
Total number of contacts3
DATASHEET
IEC Inlet Filters FN 9226
HF Performance EMC/EMI Filter
Rated currents up to 10 A
Faston connection
Optional PCB through hole connection
Optional medical versions (B type)
Approvals
Good HF coupling to the equipment housing
The FN 9226 IEC inlet filter combines an IEC inlet and
mains filter with excellent filter attenuation in a small
form factor. The FN 9226 is designed for printed circuit
board mounting with good HF coupling to the
equipment housing. Choosing the FN 9226 power
entry module brings you the rapid availability of a
standard filter associated with the necessary safety
acceptances. Standard IEC connector filters are a
practical solution helping you to pass EMI system
approval in a short time. A wide selection on current
ratings, output connections and low leakage versions
for medical applications helps you to select the
desired solution for your application.
Technical specifications
Maximum continuous operating voltage
Operating frequency
Rated currents
Approvals by rated current
High potential test voltage
250 VAC, 50/60 Hz
dc to 400 Hz
Features and benefits
High conducted attenuation performance, based on
chokes with high saturation resistance and excellent
thermal behavior
Rear flange mounting
Optional low leakage current versions for medical
applications
Faston connection or PCB through hole pins
Good HF coupling
Rated currents up to 10 A
1 to 10 A @ 50 °C
1 to 10 A (ENEC, UL, CSA)
P –> PE 2000 VAC for 2 sec (standard types)
P –> N 760 VAC for 2 sec
P –> PE 2500 VAC for 2 sec (B types)
IP40 according IEC 60529
Protection category
Temperature range (operation and storage)
Design corresponding to
Flammability corresponding to
MTBF @ 40°C/230V (Mil-HB-217F)
-25 °C to +85 °C (25/85/21)
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
UL 94 V-2 or better
800,000 hours
Custom-specific versions are available on request
Typical applications
Portable electrical and electronic equipment
Small to medium-sized machines and household
equipment
Single-phase power supplies, switch-mode power
supplies
Consumer goods
Test and measurement equipment
EDP and office equipment
Medical equipment
Rack mounting equipment

FN9226-3-02 Related Products

FN9226-3-02 FN9226-6-02 FN9226B-1-02 FN9226B-6-02
Description 8-bit Microcontrollers - MCU 96KB FL 3328bytes RAM 36I/O USB Connectors WR-COM Type A 4Pin Up Right Female AC Power Entry Modules MALE 3POS, 250VAC 1A 1 PORT AC Power Entry Modules 6A MEDICAL PCB MOUNT W/EARTH LINE CHOKE
Is it lead-free? Lead free Lead free Lead free Lead free
Is it Rohs certified? conform to conform to conform to conform to
Maker Schaffner Schaffner Schaffner Schaffner
package instruction ROHS COMPLIANT ROHS COMPLIANT ROHS COMPLIANT ROHS COMPLIANT
Reach Compliance Code compliant compliant compliant compliant
Other features STANDARDS: IEC 60939; CSA 22.2; UL 94V-2 STANDARDS: IEC 60939; CSA 22.2; UL 94V-2 STANDARDS: IEC 60939; CSA 22.2; UL 94V-2 STANDARDS: IEC 60939; CSA 22.2; UL 94V-2
Connector type MAINS POWER CONNECTOR MAINS POWER CONNECTOR MAINS POWER CONNECTOR MAINS POWER CONNECTOR
Contact to complete cooperation NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
Contact point gender MALE MALE MALE MALE
Contact material NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
Coupling type SNAP SNAP SNAP SNAP
DIN compliance NO NO NO NO
IEC compliance YES YES YES YES
MIL compliance NO NO NO NO
Power Connector Ratings 3A, 250VAC 6A, 250VAC 1A, 250VAC 6A, 250VAC
Installation type BOARD AND PANEL BOARD AND PANEL BOARD AND PANEL BOARD AND PANEL
Options GENERAL PURPOSE GENERAL PURPOSE GENERAL PURPOSE GENERAL PURPOSE
Termination type SOLDER SOLDER SOLDER SOLDER
Total number of contacts 3 3 3 3
ECCN code EAR99 EAR99 - EAR99
Solution for Goto Definition and Goto Reference not being used in MDK
[font=宋体]In the process of using RealView MDK for embedded software development, we may need to know the type of a variable or the value of a constant. Or find the prototype and definition of a functi...
jiladei Embedded System
STEVAL-IDB007V1 Challenge achieves lower power consumption
[i=s] This post was last edited by littleshrimp on 2018-2-1 22:33 [/i] [align=left][font=微软雅黑, sans-serif][size=14pt] The previous code measured the data once every certain period of time and then use...
littleshrimp ST - Low Power RF
Multi-parameter debugging signal source-system structure
Multi-parameter debugging signal source-system structure The basic structure is shown in PDF...
蓝雨夜 ADI Reference Circuit
How to use software to divide frequency modulation?
Anyone who has played this before, please break the program and see....
天使疯子 Embedded System
[Original] EDA data sharing
[Share] Summary: How to display component values in Allegro LayoutSometimes you need to display the value of a component in Layout, for example, you need to display the name of each key in a matrix ke...
护花使者 FPGA/CPLD
Summary: annysky2012's practical journey of motor development based on "STM32F746ZG+IHM07M1"
Updated: January 7, 2022@annysky2012[Development and application based on NUCLEO-F746ZG motor] 1. Development board introduction[Development and application based on NUCLEO-F746ZG motor] 2. Based on S...
nmg Motor Drive Control(Motor Control)

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 42  449  1503  1515  811  1  10  31  17  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号