https://www.phoenixcontact.com/in/products/3248338
Micro feed-through terminal block - MP 20X1,5-F OG - 3248338
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Micro feed-through terminal block, internally jumpered, with fastening flange, nom. voltage: 500 V, nominal
current: 17.5 A, connection method: Push-in connection, number of connections: 20, cross section: 0.14
mm² - 1.5 mm², AWG: 26 - 16, width: 59.7 mm, height: 17.8 mm, color: orange, mounting type: Direct
mounting with flange
Your advantages
Space-saving, thanks to the compact design
Flexible use, thanks to DIN rail and direct mounting
Space-saving potential distribution, thanks to compact micro potential distributors
Convenient test options, thanks to test openings at every terminal point
Clear arrangement thanks to marking of all terminal points
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
Weight per Piece (excluding packing)
Custom tariff number
Country of origin
4055626252988
99.990 g
85369010
Poland
20 pc
20 pc
Technical data
General
Number of levels
Number of connections
Potentials
Nominal cross section
Color
Insulating material
Flammability rating according to UL 94
1
20
1
1.5 mm²
orange
PA
V0
01/23/2019 Page 1 / 7
https://www.phoenixcontact.com/in/products/3248338
Micro feed-through terminal block - MP 20X1,5-F OG - 3248338
Technical data
General
Rated surge voltage
Degree of pollution
Overvoltage category
Insulating material group
Maximum power dissipation for nominal condition
Ambient temperature (operation)
Maximum load current
Nominal current I
N
Nominal voltage U
N
Open side panel
Shock protection test specification
Back of the hand protection
Finger protection
Result of surge voltage test
Surge voltage test setpoint
Result of power-frequency withstand voltage test
Power frequency withstand voltage setpoint
Result of the test for mechanical stability of terminal points (5 x
conductor connection)
Result of bending test
Bending test rotation speed
Bending test turns
Bending test conductor cross section/weight
Tensile test result
Conductor cross section tensile test
Tractive force setpoint
Conductor cross section tensile test
Tractive force setpoint
Result of tight fit on support
Tight fit on carrier
Setpoint
Result of voltage-drop test
Requirements, voltage drop
Result of temperature-rise test
Short circuit stability result
Conductor cross section short circuit testing
Short-time current
Result of thermal test
Ageing test for screwless modular terminal block temperature cycles
Proof of thermal characteristics (needle flame) effective duration
6 kV
3
III
I
0.56 W
-60 °C ... 130 °C
17.5 A
17.5 A
500 V
No
DIN EN 50274 (VDE 0660-514):2002-11
guaranteed
guaranteed
Test passed
7.3 kV
Test passed
1.89 kV
Test passed
Test passed
10 rpm
135
0.14 mm² / 0.2 kg
1.5 mm² / 0.4 kg
Test passed
0.14 mm²
10 N
1.5 mm²
40 N
Test passed
NS 15
1N
Test passed
≤ 3.2 mV
Test passed
Test passed
1.5 mm²
0.18 kA
Test passed
192
30 s
01/23/2019 Page 2 / 7
https://www.phoenixcontact.com/in/products/3248338
Micro feed-through terminal block - MP 20X1,5-F OG - 3248338
Technical data
General
Result of aging test
Oscillation, broadband noise test result
Test specification, oscillation, broadband noise
Test spectrum
Test frequency
ASD level
Acceleration
Test duration per axis
Test directions
Shock test result
Test specification, shock test
Shock form
Acceleration
Shock duration
Number of shocks per direction
Test directions
Relative insulation material temperature index (Elec., UL 746 B)
Temperature index of insulation material (DIN EN 60216-1 (VDE
0304-21))
Static insulating material application in cold
Test passed
Test passed
DIN EN 50155 (VDE 0115-200):2008-03
Service life test category 2, bogie-mounted
f
1
= 5 Hz to f
2
= 250 Hz
6.12 (m/s ) /Hz
3.12 g
5h
X-, Y- and Z-axis
Test passed
DIN EN 50155 (VDE 0115-200):2008-03
Half-sine
30g
18 ms
3
X-, Y- and Z-axis (pos. and neg.)
130 °C
130 °C
-60 °C
2 2
Dimensions
Width
Length
Height
Hole diameter
Drill hole spacing
59.7 mm
20 mm
17.8 mm
3.2 mm
49.2 mm
Connection data
Connection method
Connection in acc. with standard
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section AWG min.
Conductor cross section AWG max.
Conductor cross section flexible min.
Conductor cross section flexible max.
Min. AWG conductor cross section, flexible
Max. AWG conductor cross section, flexible
Conductor cross section flexible, with ferrule without plastic sleeve min.
Conductor cross section flexible, with ferrule with plastic sleeve min.
Push-in connection
IEC 60947-7-1/IEC 60947-7-2
0.14 mm²
1.5 mm²
26
16
0.14 mm²
1.5 mm²
26
16
0.25 mm²
0.25 mm²
01/23/2019 Page 3 / 7
Conductor cross section flexible, with ferrule without plastic sleeve max. 1.5 mm²
https://www.phoenixcontact.com/in/products/3248338
Micro feed-through terminal block - MP 20X1,5-F OG - 3248338
Technical data
Connection data
Conductor cross section flexible, with ferrule with plastic sleeve max.
Stripping length
Internal cylindrical gage
1.5 mm²
8 mm ... 10 mm
A1 / B1
Standards and Regulations
Connection in acc. with standard
Flammability rating according to UL 94
IEC 60947-7-1/IEC 60947-7-2
V0
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings
Circuit diagram
Classifications
eCl@ss
eCl@ss 4.0
eCl@ss 4.1
eCl@ss 5.0
eCl@ss 5.1
eCl@ss 6.0
eCl@ss 7.0
eCl@ss 9.0
27141120
27141120
27141120
27141100
27141100
27141120
27141190
ETIM
ETIM 2.0
ETIM 3.0
ETIM 4.0
ETIM 5.0
ETIM 6.0
EC000897
EC000897
EC000897
EC000897
EC000897
UNSPSC
UNSPSC 6.01
UNSPSC 7.0901
UNSPSC 11
UNSPSC 12.01
UNSPSC 13.2
30211811
39121410
39121410
39121410
39121410
01/23/2019 Page 4 / 7
https://www.phoenixcontact.com/in/products/3248338
Micro feed-through terminal block - MP 20X1,5-F OG - 3248338
Approvals
Approvals
Approvals
CSA / UL Recognized / cUL Recognized / IECEE CB Scheme / VDE Zeichengenehmigung / cULus Recognized
Ex Approvals
Approval details
CSA
Nominal voltage UN
Nominal current IN
mm²/AWG/kcmil
D
150 V
15 A
26-14
http://www.csagroup.org/services-industries/product-listing/
B
300 V
15 A
26-14
C
300 V
15 A
26-14
13631
UL Recognized
Nominal voltage UN
Nominal current IN
mm²/AWG/kcmil
D
150 V
15 A
26-14
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
B
300 V
15 A
26-14
C
300 V
15 A
26-14
FILE E 60425
cUL Recognized
Nominal voltage UN
Nominal current IN
mm²/AWG/kcmil
D
150 V
15 A
26-14
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
B
300 V
15 A
26-14
C
300 V
15 A
26-14
FILE E 60425
IECEE CB Scheme
http://www.iecee.org/
DE1-59408
01/23/2019 Page 5 / 7