EEWORLDEEWORLDEEWORLD

Part Number

Search

VI-JTF-MX-F3

Description
Isolated DC/DC Converters VI J00/200 - 110 Vin, 72 Vout, 75 W, M Product Grade
CategoryPower/power management    The power supply circuit   
File Size655KB,8 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Parametric View All

VI-JTF-MX-F3 Online Shopping

Suppliers Part Number Price MOQ In stock  
VI-JTF-MX-F3 - - View Buy Now

VI-JTF-MX-F3 Overview

Isolated DC/DC Converters VI J00/200 - 110 Vin, 72 Vout, 75 W, M Product Grade

VI-JTF-MX-F3 Parametric

Parameter NameAttribute value
package instruction,
Reach Compliance Codecompliant
Other featuresREMOTE SHUTDOWN
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
CertificationTUV, UL
Efficiency (main output)90%
high12.7 mm
Maximum input voltage160 V
Minimum input voltage66 V
Nominal input voltage110 V
length61 mm
Maximum grid adjustment rate0.2%
Maximum load regulation0.2%
Maximum operating temperature100 °C
Minimum operating temperature-55 °C
Maximum total power output75 W
width57.9 mm
Base Number Matches1
Half Brick, DC-DC Converters
VI-J00
VE-J00
®
S
C
US
C
NRTL
US
25 to 100 Watts
Features & Benefits
Isolated output
Up to 50W/in
3
cURus, cTÜVus
CE Marked
Up to 90% efficiency
Size: 2.28” x 2.4” x 0.5”
(57,9 x 61,0 x 12,7mm)
Remote sense and current limit
Logic disable
Wide range output adjust
ZCS power architecture
Low noise FM control
RoHS compliant (VE verisons)
Product Highlights
The VI-J00 MiniMod family established a new standard in component-level DC-DC
converters. This “junior” size complement to the higher power VI-200 family offers up
to 100W of isolated and regulated power in a board mounted package. With thousands
of input/output/power combinations, and with a maximum operating temperature
rating of 100°C, the MiniMod provides nearly unlimited flexibiliy for power system
designers to meet demanding time to market requirements.
Utilizing Vicor’s “zero-current-switching” forward converter technology, proven
by an installed base of over 8 million units, the MiniMod family combines state of
the art power density with the efficiency, low noise and reliability required by next
generation power systems.
Part Numbering
VI
J
6
1
C
W
Family
VI
=Non-RoHS
VE
= RoHS
Series
J
= J00
0
= 12V
V
= 24V
1
= 24V
W
= 24V
2
= 36V
3
= 48V
Input
N
= 48V
4
= 72V
T
= 110V
5
= 150V
6
= 300V
7
= 150/300V
Z
= 2V
Y
= 3.3V
0
= 5V
X
= 5.2V
W
= 5.5V
V
= 5.8V
T
= 6.5V
R
= 7.5V
Output
M
= 10V
1
= 12V
P
= 13.8V
2
= 15V
N
= 18.5V
3
= 24V
L
= 28V
J
= 36V
K
= 40V
4
= 48V
H
= 52V
F
= 72V
D
= 85V
B
= 95V
Grade
E
= –10 to 100°C
I
= – 40 to 100°C
M
= –55 to 100°C
≥ 5V
Power
< 5V
W
= 20A
X
= 15A
Y
= 10A
Z
= 5A
C
= –25 to 100°C
W
= 100W
X
= 75W
Y
= 50W
Z
= 25W
Note:
For additional
packaging options,
please see page 5.
VI-J00 DC-DC Converters
Page 1 of 7
Rev 3.0
06/2017
How to Design a Switching Power Supply
How to design a simple switching power supply with an output of 5V and 3A. Input 220V...
lqlkmqj Power technology
Recruiting PLC hardware R&D engineers
[align=left][size=6][b]PLC hardware R&D engineer salary: 180,000-280,000 [/b][/size][/align][align=left][size=6][b] [/b][/size][/align][align=left](I) Job responsibilities: [/align][align=left]R&D of ...
cindy95133 Recruitment
About the problem that the FRDM-KL03Z development board SDK helloword routine cannot be compiled
I downloaded the KSDK_1.0.0-KL03Z SDK package from the FREESCALE official website and used KEIL V5.13 to compile the helloword example hello_world.uvmpw. The result is the following error: debug\hello...
andrews0925 NXP MCU
Help
This is a paragraph from the 5438 datasheet, which says "Each sector can be completely powered down to save leakage, however all data is lost." What does it mean?...
zzbaizhi Microcontroller MCU
Ask a question about STM32 ADC
Now there are 3 AD channels, which need to be refreshed every once in a while, but the time interval between reading the 3 channels should be very short. My idea is to set these 3 channels to injectio...
zhufuzhufu stm32/stm8
Design and implementation of automatic cable fault location system
Design and implementation of automatic cable fault location system Abstract: In order to deal with the frequent telecommunication cable interruption accidents, a design scheme for an automatic cable f...
feifei Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1169  1808  707  696  2800  24  37  15  57  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号