Embedded Power for
Business-Critical Continuity
LPS350 Series
350 Watts
Total Power: 350 Watts
Input Voltage: 85-264 Vac
120 - 300 Vdc
# of Outputs: Single
Rev. 11.27.12
LPS350 Series
1 of 3
Special Features
• Active power factor correction
• IEC EN61000-3-2 compliance
• Remote sense on
• Power fail and remote inhibit
• Single wire current sharing
• Built-in EMI filter
• 2 Supervisory output 5 V and 12 V
• Overvoltage protection
• Overload protection
• Thermal overload protection
• DC power good
• 130 KHz switching frequency
• Optional with fan cover -CF
• Cover -C
• Optional end-mounted fan -CEF
Electrical Specifications
Input
Input ra nge
Frequency
Inrush current
Efficiency
EMI filter
85 - 264 VAC; 120 - 300 VDC
47 - 440 Hz
38 A max, cold start @ 25 °C
75% typical at full load
FCC Class B conducted and radiated
CISPR 22 Class B conducted and radiated
EN55022 Class B conducted and radiated
VDE 0878 PT3 Class B conducted and radiated
0.99 typical
0.5 mA @ 50/60 Hz, 264 VAC input
Power factor
Safety ground
leakage current
Output
Maximum power
Adjustment range
Supervisory output
With cover: 350 W with 30 CFM forced air, (-C) (-CF) (-CEF)
2:1 wide ratio
5 V @ 500 mA regulated, 12 @ 150 mA x2
20 ms @ 350 W load, 115 VAC nominal line at factory voltage settings
Short circuit protection on all outputs. Case overload protected @
110 - 145% above peak rating
Safety
VDE
UL
CSA
0805/EN60950 (IEC950)
21310-3336-0001
UL1950 EI86249
CSA 22.2-234 Level 5
LR109492C
Hold-up time
Overload protection
Overvoltage protection 5 V output: 5.7 - 6.7 VDC. Other models 10% to 25% above nominal output
NEMKO
EN 60950/EMKO-TUE
P98102115 (74-sec) 203
BABT
CB
CE
EN60950/BS7002 608857,
608858, 609097
Certificate and report
5734, 6280, 6281
Mark (LVD)
Embedded Power for
Business-Critical Continuity
Logic Control
Power failure
Remote on/off
DC-OK
Remote sense
TTL logic signal goes high 50 - 150 msec after 5 V output. It
goes low at least 4 msec before loss of regulation
Requires an external contact (N.O or N.C) to inhibit outputs
TTL logic goes high 50 - 150 msec after 5 V output. It goes low
when there is loss of regulation
Compensates for 0.5 V lead drop min. Will operate without
remote sense connected. Reverse connection protected
Rev. 11.27.12
LPS350 Series
2 of 3
Environmental Specifications
Operating temperature:
Storage temperature:
0° to 50°C ambient;
derate each output at 2.5% per degree from 50° to 70 °C
-40 °C to +85 °C
Pin Assignments
SK1
PIN 1
PIN 2
PIN 3
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
PIN 9
PIN 10
PIN 1
PIN 2
PIN 1
PIN 2
PIN 1
PIN 2
Neutral
Line
Ground
N/C
N/C
+ Sense
- Sense
POK
C. Share
DC - OK
Inhibit (N.O.)
Inhibit (N.C.)
COM
+ Fan 1
(12V@150mA)
– Common
+ 5V aux
(5V@100mA)
– Common
+ Fan 2
(12V@150mA)
– Common
Temperature coefficient: ± 0.4% per °C
Electromagnetic
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
susceptibility:
Humidity:
Operating; non-condensing 5% to 95%
Vibration:
Three orthogonal axes, sweep at 1 oct/min, 5 min.
dwell at four major resonances 0.7 G peak 5Hz to 500Hz,
operational
> 550,000 hours at full load and 25 °C ambient conditions
SK3
MTBF demonstrated:
SK4
Ordering Information
Model
Number
Output
Voltage
Minimum
Load
0 A
0 A
0 A
0 A
Maximum Load
with Convection
Cooling
70 A
29.2 A
23.3 A
14.6 A
Peak Load 1 Regulation 2
80 A
33 A
26 A
16 A
± 2%
± 2%
± 2%
± 2%
Ripple P/P
(PARD)3
50 mV
120 mV
150 mV
240 mV
SK5
SK6
LPS352-C 5 V (3 - 6 V)
LPS353-C
12 V (6 - 12 V)
LPS354-C 15 V (12 - 24 V)
LPS355-C
24 V (24 - 48 V)
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory
settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage
and load ranges.
4. If optional CF or CEF fans are not used, 30CFM forced air cooling needs to be provided and is required
through the length of the power supply. Not convection rated.
5. Output voltage adjustment requires a 1A load.
6. Remote inhibit resets OVP latch.
Note: -CF suffix added to the model number indicates cover with fan,
-CEF suffix added to model number indicates end-mounted fan chassis.
Mating Connectors
SK3
Molex: 22-01-1104
PINS: 08-70-0057
SK4
Molex 22-01-3027
PINS: 08-50-0114
SK5
Molex 22-01-3027
PINS: 08-50-0114
SK6
Molex 22-01-3027
PINS: 08-50-0114
Astec Connector Kit #70-841-011, includes all of
the above.
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
Americas
6-32 (2 pla es
)
ain O tp t
er inal
lo
1
ve -ve
Rev. 11.27.12
LPS350 Series
3 of 3
3 (6 pla es
)
3
1 2 3 4 5 6 7 8 9 10
3 (4 pla es
)
6-32
C (8 pla es
)
.24 (6.1)
1
5 (5 a
4 Fan
6 Fan
)
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
3.68
(93.6)
5.46
(138.6)
6.64
(168.6)
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
(-CF)
Cover
with fan
3.15
(80)
8.52
(216.4)
9.0
(228.6)
10.78
(273.8)
2.17
(55)
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
6-32 (3 pla es
)
3 2 1
1
Optional
(-CEF)
Cover
with fans
2.5
(63.5)
3.5
(88.9)
1.18 (30.0)
For global contact, visit:
www.Emerson.com/EmbeddedPower
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
5.0 (127.0)
.55
(14)
1.30
(33.0)
.79
(20)
3.42 (87.0)
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ± .02”.
3. Specifications are at factory settings
4. To enable normally closed Remote Inhibit, cut jumper J1.
5. Mounting maximum insertion depth is 0.12”.
6. Warranty: 2 year
7. Weight: 3.6 lb. / 1.64 kg.
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson and the Emerson Network Power
logo are trademarks of Emerson Electric Co.
©2012 Emerson Electric Co.
All rights reserved.