Railway/Transportation system applications including communications systems, informa-
tion display, lighting, control systems, ticket machines, passenger
entertainment, public address systems, door control, industrial power systems and power
generation systems.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use
advanced power processing, control and
packaging technologies to provide the
performance, flexibility, reliability and cost
effectiveness of a mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V110B24C200BL
V1 1 0 B
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
= - 10 to +100 - 20 to +125
C
= - 20 to +100 - 40 to +125
T
= - 40 to +100 - 40 to +125
H
= - 40 to +100 - 55 to +125
M
= - 55 to +100 - 65 to +125
B
Output Power
V
OUT
P
OUT
3.3V
75W, 100W
5V
100W, 150W
8V
150W
12V
150W, 200W
15V
150W, 200W
24V
150W, 200W
28V
150W, 200W
36V
150W, 200W
48V
150W, 200W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
3V3
= 3.3V
5
= 5V
8
=
8V
12
=
12V
15
=
15V
24
=
24V
28
=
28V
36
=
36V
48
=
48V
110V Mini Family
Page 1 of 14
Rev 3.6
06/2017
vicorpower.com
800 927.9474
110V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
54
155.5
64
56
161.7
169.4
1.3
Min
66
Typ
110
Max
154
250
65.4
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
Notes
Per EN50155 and GBT-25119
<100ms
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
–0.5 to 4.7
–0.5 to 7.0
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 47.4
–0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 9.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20264)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.16
0.14
8.0
1.9
83
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
110V Mini Family
Page 2 of 14
Rev 3.6
06/2017
vicorpower.com
800 927.9474
110V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
3.1
(89.3)
3.5
(99.6)
100
3000
1500
500
10
3.5
(100.3)
3.9
(110.6)
115
cURus, cTÜVus, CE
3.9
(111.3)
4.3
(121.6)
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
110V Mini Family
Page 3 of 14
Rev 3.6
06/2017
vicorpower.com
800 927.9474
110V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3
V
OUT
, 100W (e.g. S110B3V3C100BL, V110B3V3C100BL)
Parameter
Efficiency
S110B3V3C100BL (enhanced efficiency)
V110B3V3C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.1
81.5
4.14
Typ
86.5
82.6
80
4.3
2.6
±0.02
34.8
34.8
Max
Unit
%
100
4.46
3.4
±0.2
30.3
41
41
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
30.9
21.2
3.3
V
OUT
, 75W (e.g. S110B3V3C75BL, V110B3V3C75BL)
Parameter
Efficiency
S110B3V3C75BL (enhanced efficiency)
V110B3V3C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.2
81.0
4.14
Typ
86.0
81.9
80
4.3
2.6
±0.02
26.1
26.1
Max
Unit
%
100
4.46
3.6
±0.2
22.73
30.7
30.7
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
23.1
15.8
5
V
OUT
, 150W (e.g. S110B5C150BL, V110B5C150BL)
Parameter
Efficiency
S110B5C150BL (enhanced efficiency)
V110B5C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.4
83.9
6.03
Typ
88.5
84.8
85
6.25
5.3
±0.02
34.5
34.5
Max
Unit
%
107
6.47
7.5
±0.2
30
40.5
40.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
30.6
21
5
V
OUT
, 100W (e.g. S110B5C100BL, V110B5C100BL)
Parameter
Efficiency
S110B5C100BL (enhanced efficiency)
V110B5C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.0
80.5
6.03
Typ
86.0
81.9
240
6.25
3.4
±0.02
23
23
Max
Unit
%
300
6.47
4.4
±0.2
20
27
27
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
20.4
14
110V Mini Family
Page 4 of 14
Rev 3.6
06/2017
vicorpower.com
800 927.9474
110V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
8
V
OUT
, 150W (e.g. S110B8C150BL, V110B8C150BL)
Parameter
Efficiency
S110B8C150BL (enhanced efficiency)
V110B8C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.3
85.5
9.36
Typ
89.0
86.8
200
9.7
5.2
±0.02
21.6
21.6
Max
Unit
%
250
10.1
6.4
±0.2
18.75
25.4
25.4
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
19.1
13.1
12
V
OUT
, 200W (e.g. S110B12C200BL, V110B12C200BL)
Parameter
Efficiency
S110B12C200BL (enhanced efficiency)
V110B12C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.9
86.0
13.7
Typ
89.0
87.2
185
14.3
7
±0.02
19.2
19.2
Max
Unit
%
232
14.9
8.2
±0.2
16.67
22.6
22.6
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
17
11.6
12
V
OUT
, 150W (e.g. S110B12C150BL, V110B12C150BL)
Parameter
Efficiency
S110B12C150BL (enhanced efficiency)
V110B12C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
88.9
87.0
13.7
Typ
90.0
88.0
160
14.3
4.7
±0.02
14.4
14.4
Max
Unit
%
200
14.9
5.8
±0.2
12.5
16.9
16.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.7
8.75
15
V
OUT
, 200W (e.g. V110B15C200BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.0
17.1
Typ
88.1
240
17.8
7.3
±0.02
15.3
15.3
Max
300
18.5
8.2
±0.2
13.33
18
18
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
I am now making a tool to update u-boot, fs and other things to the target board via USB. The target board only has u-boot at the beginning. The previous tool also needs to use a port line and then us...
Impedance matching of power amplifiers
Higher Q values should be considered because higher Q values provide higher attenuation of the amplifier harmonics. Because current and voltage limiting in the o...
[i=s]This post was last edited by yangwillie on 2014-5-6 12:57[/i] [media=x,500,375]http://v.youku.com/v_show/id_XNzA4MjczNzQ0.html[/media]During the development process, it took a long time to debug ...
I made 3 components myself. Their functions are check, latch and add. They are all successful when used separately. They can also be used together.However, when the output of check is connected to the...
This issue explains the DDR wiring requirements and equal length requirements in high-speed PCB design. Wiring requirements Data signal group: With the ground plane as a reference, provide a complete ...
TD-SCDMA (Time Division Synchronous Code Division Multiple Access) is one of the three major standards for the third generation of mobile communications. It is a communication standard with indepen...[Details]
Digital signal processors have efficient numerical computing capabilities and can provide a good development environment, while programmable logic devices have highly flexible configurability. This...[Details]
Digital-to-analog converters (ADCs) provide the critical conversion of analog signals to digital signals in many systems. They perform amplitude quantization of an analog input signal to a binary fini...[Details]
A biped robot joint constructed by pneumatic artificial muscles is introduced. The joint uses the flexible characteristics of pneumatic artificial muscles to effectively control the impact of the la...[Details]
Designers of hearing aids have stringent requirements. Hearing aids must be small enough to fit in or behind the ear, operate on ultra-low power, and be free of noise or distortion. To meet these requ...[Details]
Overview
Bioelectric signals are very weak, and there is strong interference when detecting them. Therefore, there are many technical difficulties in designing high-quality bioelectric ampli...[Details]
With the development of automatic control technology, the application of precision air pressure generation and control technology is becoming more and more extensive. However, the traditional valve...[Details]
JTAG Technology Introduction
One disadvantage of shrinking technology is that the complexity of testing small devices increases dramatically. When the board area is large, the board is tested...[Details]
This issue will briefly introduce the test related to spectrum - occupied bandwidth.
Definition: Occupied bandwidth refers to the bandwidth corresponding to 99% of the total transmitted power, cent...[Details]
To ensure the success of China's TD-SCDMA network commercialization, operators and equipment suppliers need to conduct a large number of tests on networked equipment, among which RF testing is...[Details]
Broadband services supporting triple play voice, video and data are evolving for first mile customers (small businesses and homes). A key factor in this FTTx evolution is GPON (Gigabit Passive Opti...[Details]
introduction
In engineering practice, ultrasonic waves are often used to measure distances because of their strong directivity, slow energy consumption, and long propagation distance in th...[Details]
This article will discuss a common problem in wireless mobile data reception.
Problems facing RF receivers
The common problem faced by RF receivers is that the same hardware must be used ...[Details]
Introduction
Wireless operators are driving demand for broadband and data rates by offering enhanced data services to increase average revenue per user (ARPU). The need to provide users with ...[Details]
AD604 is a product of Analog Devices (AD). Compared with similar products, AD604 has the characteristics of ultra-low noise, high precision, continuously adjustable gain, and the decibel (dB...[Details]