Industrial and process control, distributed power, medical, ATE, communications, defense
and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V24A12T400BL2
24A
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
= - 10 to +100 - 20 to +125
C
= - 20 to +100 - 40 to +125
T
= - 40 to +100 - 40 to +125
H
= - 40 to +100 - 55 to +125
M
= - 55 to +100 - 65 to +125
B
Output Power
P
OUT
200W, 264W
300W, 400W
400W
300W
300W, 400W, 500W
300W, 400W
300W, 400W, 500W
300W, 400W, 500W
300W, 400W
300W, 400W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
3V3
= 3.3V
5
= 5V
6.5
= 6.5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
V
OUT
3.3V
5V
6.5V
8V
12V
15V
24V
28V
36V
48V
24V Maxi Family
Page 1 of 15
Rev 6.8
06/2017
vicorpower.com
800 927.9474
24V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
14.8
36.3
17.5
15.3
37.8
39.6
4.0
Min
18
Typ
24
Max
36
50
17.9
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
Notes
These modules will operate at up to 75% of rated power down
to 16V
IN
after start up at >18V
IN
<100ms
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to -OUT, +Sense to -OUT – Absolute Maximum Ratings
3.3V
5V
6.5V
8V
12V
15V
24V
28V
36V
48V
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 9.0
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.2
-0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 10.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20263)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.08
0.07
4.9
1.1
165
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
24V Maxi Family
Page 2 of 15
Rev 6.8
06/2017
vicorpower.com
800 927.9474
24V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
6.5
(184.3)
7.4
(209.3)
100
3000
1500
500
10
7.3
(207.5)
8.2
(232.5)
115
cURus, cTÜVus, CE
8.1
(230.7)
9.0
(255.7)
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
24V Maxi Family
Page 3 of 15
Rev 6.8
06/2017
vicorpower.com
800 927.9474
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3V
OUT
, 264W (e.g. S24A3V3C264BL, V24A3V3C264BL)
Parameter
Efficiency
S24A3V3C264BL (enhanced efficiency)
V24A3V3C264BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.0
80.0
4.14
Typ
86.0
81.4
75
4.3
8
±0.02
92
92
Max
Unit
%
94
4.46
12
±0.2
80
108
108
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
3.3V
OUT
, 200W (e.g. S24A3V3C200BL, V24A3V3C200BL)
Parameter
Efficiency
S24A3V3C200BL (enhanced efficiency)
V24A3V3C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.0
73.9
4.48
Typ
86.0
79.9
43
4.65
6.2
±0.02
69.7
69.7
Max
Unit
%
54
4.82
10
±0.2
60.6
81.9
81.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.8
42.4
5V
OUT
, 400W (e.g. S24A5C400BL, V24A5C400BL)
Parameter
Efficiency
S24A5C400BL (enhanced efficiency)
V24A5C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.0
80.0
6.03
Typ
86.5
84.5
152
6.25
6.8
±0.02
92
92
Max
Unit
%
190
6.47
10.1
±0.25
80
104
104
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
5V
OUT
, 300W (e.g. S24A5C300BL, V24A5C300BL)
Parameter
Efficiency
S24A5C300BL (enhanced efficiency)
V24A5C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.5
82.5
6.03
Typ
84.4
84.4
120
6.25
7.2
±0.02
69
69
Max
Unit
%
150
6.47
8.8
±0.2
60
81
81
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.2
42
24V Maxi Family
Page 4 of 15
Rev 6.8
06/2017
vicorpower.com
800 927.9474
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
6.5V
OUT
, 400W (e.g. S24A6V5C400BL, V24A6V5C400BL)
Parameter
Efficiency
S24A6V5C400BL (enhanced efficiency)
V24A6V5C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
85.0
85.0
7.7
Typ
86.1
86.1
220
7.98
9.2
±0.02
70.7
70.7
Max
Unit
%
275
8.26
10.5
±0.2
61.5
83.1
83.1
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
62.7
43
8V
OUT
, 300W (e.g. S24A8C300BL, V24A8C300BL)
Parameter
Efficiency
S24A8C300BL (enhanced efficiency)
V24A8C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.6
85.6
9.36
Typ
86.5
86.5
215
9.7
8.7
±0.02
43.1
43.1
Max
Unit
%
269
10.1
13.9
±0.2
37.5
50.7
50.7
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
38.2
26.2
12V
OUT
, 500W (e.g. S24A12C500B, V24A12C500BL)
Parameter
Efficiency
S24A12C500B (enhanced efficiency)
V24A12C500BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.7
86.0
13.8
Typ
88.2
87.5
272
14.3
10.8
±0.02
47.9
47.9
Max
Unit
%
340
14.8
12.0
±0.2
41.67
56.3
56.3
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
42.5
29.2
12V
OUT
, 400W (e.g. S24A12C400BL, V24A12C400BL)
Parameter
Efficiency
S24A12C400BL (enhanced efficiency)
V24A12C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.0
87.0
13.7
Typ
89.5
88.3
250
14.3
6.8
±0.02
38.4
38.4
Max
Unit
%
320
14.9
10.2
±0.2
33.33
43.5
43.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
I am very happy today that the familiar netizen Ximen came to visit us! Brother Ximen still thought of us when he was in a low mood. Thank you very much for his recognition and appreciation. Of course...
I worked very hard and cheated to get these three crack codes. . . The destroyer will update the DR4.44 engine in a while. At that time, the crack codes will probably be too difficult to get. If you w...
[i=s]This post was last edited by Xiao Liuzi on 2018-7-13 16:55[/i] [color=#4f4f4f][font="][size=14px]The hardware is a Linux system i.mx287 arm processor. How can I implement the FTP client method on...
I set up a watchdog timer to send a data packet today! I defined a watchdog ID after creating a watchdog in the main function WDOG_ID wid;, but I couldn't debug it! The system error prompts "parse err...
I plan to drive a USB UVC camera on a microcontroller (mainly Cortex-M series). This post is an analysis of the enumeration process under Windows. After the camera is plugged in, the enumeration is in...
To facilitate communication, I created a MicroPython public account to send the latest MicroPython news, programs, etc. You can follow it. [img=200,200]http://www.micropython.org.cn/data/attachment/fo...
Embedded systems are the replacement products of computer technology, communication technology, semiconductor technology, microelectronics technology, voice and image data transmission technology, and...[Details]
Basic principles of simulation
Simulation is a technology used in the field of embedded system development. It can bring system developers the controllability and visibility needed to integra...[Details]
TD-SCDMA terminal conformance test includes three types of tests: RF index test (reference standard: 3GPPTS34.122), protocol signaling test (reference standard: 3GPPTS34.123) and other tests (refer...[Details]
The overcurrent and overheating coordinated protection technology implemented by polymer positive temperature coefficient devices (PPTC) can protect motors, controllers and electronic components in...[Details]
introduction
In engineering practice, ultrasonic waves are often used to measure distances because of their strong directivity, slow energy consumption, and long propagation distance in th...[Details]
Electrocardiogram is an important means of diagnosing heart disease. However, due to various reasons, it is difficult to capture abnormal electrocardiograms with ordinary electrocardiographs. Although...[Details]
Industrial control
often requires multi-channel fault detection and multi-channel command control (this multi-task setting is very common). A single CPU chip is difficult to directly complete ...[Details]
1 Introduction
The high temperature tester is mainly used for temperature tracking measurement and data acquisition during the heating process. By systematically analyzing the test data,...[Details]
1 Introduction to suction laminating machine
Suction laminating machine is a kind of woodworking machinery, which can realize the laminating function of wood boards and other materials. It i...[Details]
introduction
Traditional electric actuators are easy to use and save investment, and have been widely used in production process control systems in the fields of electricity, metallurgy, petro...[Details]
Abstract:
A single pulse secondary radar reply processor implemented with EPLD. Its main functions include: reply frame pulse detection, reply information decoding, assembling reply inf...[Details]
As process nodes and die sizes continue to shrink, the number of consumer electronic products using flip-chip packaged IC devices is increasing. However, flip-chip packaging manufacturing rules hav...[Details]
With the development of science and technology, the improvement of living standards and the acceleration of the pace of modern cities, people are increasingly pursuing more convenient, practical an...[Details]
0 Introduction
The peak value of AC voltage refers to the maximum value (positive peak value) or minimum value (negative peak value) of AC voltage, which is a very important parameter in t...[Details]
introduction
As a product of the combination of channel technology and network technology, Fibre Channel is an open network with high real-time performance, high reliability, high bandwidt...[Details]