This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LFA10F-3R3-Y
6.6
3.3V 2A
LFA10F-5
10
5V 2A
LFA10F-12
10.8
12V 0.9A
LFA10F-15
10.5
15V 0.7A
LFA10F-24
12
24V 0.5A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
ACIN 100V
ACIN 200V
LFA10F-3R3-Y
LFA10F-5
LFA10F-12
LFA10F-15
LFA10F-24
*3
AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2)
0.18typ (Io=100%)
0.26typ (Io=100%)
0.11typ (Io=100%)
0.16typ (Io=100%)
50 / 60 (47 - 440)
68.0typ
74.0typ
76.5typ
77.5typ
79.5typ
68.5typ
76.0typ
79.0typ
80.0typ
83.0typ
15typ (Io=100%)
30typ (Io=100%)
0.15/0.30max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
2.0
2.0
0.9
0.7
0.5
20max
20max
48max
60max
96max
40max
40max
100max
120max
150max
80max
80max
120max
120max
120max
140max
140max
160max
160max
160max
190max
160max
240max
240max
280max
120max
120max
150max
150max
150max
160max
160max
180max
180max
180max
240max
240max
300max
300max
320max
50max
50max
120max
150max
240max
60max
60max
150max
180max
290max
20max
20max
48max
60max
96max
200typ (ACIN 100V, Io=100%)
*Start-up
time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100V, Io=100%)
2.85 to 3.63
Fixed (“Y”option is available for adjusting output voltage between
±10%)
3.30 to 3.40
4.90 to 5.30
11.50 to 12.50
14.40 to 15.60
23.00 to 25.00
Works over 105% of rating and recovers automatically
4.00 to 5.25
5.75 to 7.00
13.80 to 16.80
17.25 to 21.00
27.60 to 33.60
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000 feet) max
*3
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
Optional chassis and cover material : Electric galvanizing steel board.
¶
Dimensions in mm, [ ]=inches
¶
Mounting torque (Mounting hole of chassis) : 0.6N
-
m (6.3kgf
-
cm) max
1-1123722-5
1-1123722-2
¶
I/O Connector is Mfr. Tyco Electronics
¶
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5.
[0.63]
16
[1.26]
32
LFA-3
[2.36]
FG
CN1
5
CN2
1
2
Output(-)
Output(+)
[1.18]
Input(N)
[0.59]
50
15
FG
1
2
Output(-)
Output(+)
31.7
CN2
30
60
AC-DC Power Supplies Open Frame/ Enclosed Type
Ordering information
LFA15F
LF
1
2
A
3
15
4
F
5
-O
6
-O
R
Recommended EMI/EMC Filter
NAC-04-472
LFA
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
The EMI/EMC Filter is recommended
to connect with several devices.
1
Series name
2
Single output
3
Output wattage
4
Universal input
5
Output voltage
6
Optional
C : with Coating
G : Low leakage current
J1 : VH(J.S.T.)connector type
S : with Chassis
SN: with Chassis & cover
Y : with Potentiometer
Specification is changed at
option, refer to Instruction
Manual.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LFA15F-3R3-Y
9.9
3.3V 3A
LFA15F-5
15
5V 3A
LFA15F-12
15.6
12V 1.3A
LFA15F-15
15
15V 1A
LFA15F-24
16.8
24V 0.7A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
ACIN 100V
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
*5
LINE REGULATION[mV]
LOAD REGULATION[mV]
*5
0 to +50C
RIPPLE[mVp-p]
-10 - 0C
*1
Io=0 - 35%
0 to +50C
RIPPLE NOISE[mVp-p]
OUTPUT
-10 - 0C
*1
Io=0 - 35%
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
*2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
PROTECTION OVERVOLTAGE PROTECTION
CIRCUIT AND OPERATING INDICATION
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
ISOLATION
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
AGENCY APPROVALS
SAFETY AND
NOISE
CONDUCTED NOISE
REGULATIONS HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
EFFICIENCY[%]
*1
ACIN 100V
ACIN 200V
INPUT
LFA15F-3R3-Y
LFA15F-5
LFA15F-12
LFA15F-15
LFA15F-24
AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2)
*3
0.24typ (Io=100%)
0.35typ (Io=100%)
0.15typ (Io=100%)
0.20typ (Io=100%)
50 / 60 (47 - 440)
68.0typ
73.0typ
76.0typ
77.0typ
78.0typ
69.0typ
76.0typ
78.5typ
80.0typ
81.5typ
15typ (Io=100%) (At cold start) (Ta=25C)
30typ (Io=100%) (At cold start) (Ta=25C)
0.15/0.30max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
3.0
3.0
1.3
1.0
0.7
20max
20max
48max
60max
96max
40max
40max
100max
120max
150max
80max
80max
120max
120max
120max
140max
140max
160max
160max
160max
190max
160max
240max
240max
280max
120max
120max
150max
150max
150max
160max
160max
180max
180max
180max
240max
240max
300max
300max
320max
50max
50max
120max
150max
240max
60max
60max
150max
180max
290max
20max
20max
48max
60max
96max
200typ (ACIN 100V, Io=100%)
*Start-up
time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100V, Io=100%)
2.85 to 3.63
Fixed (“Y”option is available for adjusting output voltage between
±10%)
3.30 to 3.40
4.90 to 5.30
11.50 to 12.50
14.40 to 15.60
23.00 to 25.00
Works over 105% of rating and recovers automatically
4.00 to 5.25
5.75 to 7.00
13.80 to 16.80
17.25 to 21.00
27.60 to 33.60
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000 feet) max
*3
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
Optional chassis and cover material : Electric galvanizing steel board.
¶
Dimensions in mm, [ ]=inches
¶
Mounting torque (Mounting hole of chassis) : 0.6N
-
m (6.3kgf
-
cm) max
1-1123722-5
1-1123722-2
¶
I/O Connector is Mfr. Tyco Electronics
¶
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5.
16
PCB t=1.6
[0.63]
¶1
LFA-5
[1.26]
32
[2.36]
60
Voltage adjust
(LFA15F-3R3-Y or optional)
CN1
CN2
1
2
FG
5
Output(-)
Output(+)
[1.18]
50
30
1
2
[0.59]
CN1
CN2
Output(-)
Output(+)
[1.17]
29.7
15
AC-DC Power Supplies Open Frame/ Enclosed Type
Ordering information
LFA30F
LF
1
2
A
3
30
4
F
5
-O
6
-O
R
Recommended EMI/EMC Filter
NAC-04-472
LFA
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
The EMI/EMC Filter is recommended
to connect with several devices.
1
Series name
2
Single output
3
Output wattage
4
Universal input
5
Output voltage
6
Optional
C : with Coating
G : Low leakage current
J1 : VH(J.S.T.)connector type
S : with Chassis
SN: with Chassis & cover
Y : with Potentiometer
Specification is changed at
option, refer to Instruction
Manual.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LFA30F-3R3-Y
19.8
3.3V 6A
LFA30F-5
30.0
5V 6A
LFA30F-12
30.0
12V 2.5A
LFA30F-15
30.0
15V 2A
LFA30F-24
31.2
24V 1.3A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
ACIN 100V
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
*5
LOAD REGULATION[mV]
*5
0 to +50C
*1
RIPPLE[mVp-p]
-10 - 0C
*1
0 to +50C
*1
RIPPLE NOISE[mVp-p]
-10 - 0C
*1
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
*2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
ACIN 100V
ACIN 200V
LFA30F-3R3-Y
LFA30F-5
LFA30F-12
LFA30F-15
LFA30F-24
AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2)
*3
0.50typ (Io=100%)
0.65typ (Io=100%)
0.30typ (Io=100%)
0.35typ (Io=100%)
50 / 60 (47 - 440)
73typ
76typ
79typ
81typ
82typ
75typ
79typ
81typ
83typ
84typ
15typ (Io=100%)
(At cold start)
(Ta=25C)
30typ (Io=100%)
(At cold start)
(Ta=25C)
0.30 / 0.65max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
6.0
6.0
2.5
2.0
1.3
20max
20max
48max
60max
96max
40max
40max
100max
120max
150max
80max
80max
120max
120max
120max
140max
140max
160max
160max
160max
120max
120max
150max
150max
150max
160max
160max
180max
180max
180max
50max
50max
120max
150max
240max
60max
60max
150max
180max
290max
20max
20max
48max
60max
96max
150typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
2.85 to 3.63
Fixed (“Y”option is available for adjusting output voltage between
±10%)
3.30 to 3.40
4.90 to 5.30
11.50 to 12.50
14.40 to 15.60
23.00 to 25.00
Works over 105% of rating and recovers automatically
4.00 to 5.25
5.75 to 7.00
13.80 to 16.80
17.25 to 21.00
27.60 to 33.60
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max
*3
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
[i=s]This post was last edited by ou513 on 2016-7-28 09:51[/i] Meizu Note2 screen replacement record. Note2 was in my hands for exactly one year when my little princess broke the screen. I bought a sc...
What code is used in InTouch? Can the following query be executed? select TM,STCD1=max(STCD1),STCD2=max(STCD2),STCD3=max(STCD3) from temp_1 group by TM ORDER BY TM ASC D ELETE temp_1 go...
I would like to ask, in ATmega8, when my counter 2 works in fast PWM mode, when counter 2 and OCR2 match, does it only control OCF2 (match interrupt control bit) or OC2 (match output pin), or both? Th...
Why does this happen when my package is placed on a two-layer board? Could an expert please give me some advice? Is there a problem with the software settings?...
I want to start my own business and benefit the public. We are now looking for a suitable direction. I would like to hear your suggestions. We are all TI, so please feel free to tell us what ideas you...
With the promotion of the construction of intelligent communities in the country, anti-theft systems have become essential equipment for intelligent communities. Especially in recent years, the urg...[Details]
At present, the traffic congestion in cities is quite serious. According to relevant news reports: In China, the traffic congestion has expanded from megacities such as Beijing, Shanghai, and Guang...[Details]
Abstract: In order to generate a stable excitation signal, the design of a digital frequency synthesizer is implemented on FPGA using Verilog hardware language. The design includes accumulator, wav...[Details]
Power management solutions for today's portable application processors are becoming increasingly integrated. Total power consumption, standby and sleep current consumption affect battery size, bill...[Details]
1. With the development of modern industry and the continuous improvement of automation, some medium and large control systems have been greatly facilitated, which not only makes control easier, bu...[Details]
1 Introduction
Building Automation System (BAS) is a distributed monitoring system (DCS) designed according to distributed information and control theory. It is the result of the mutual de...[Details]
1 Introduction
With the development of control, computer, communication, network technology, etc., a new control technology, namely fieldbus, has emerged in the field of industrial control...[Details]
The potentiometer is an adjustable electronic component. The main functions of the potentiometer in the circuit are as follows:
1. Used as a voltage divider
A potentiometer is a continuou...[Details]
This controller uses PIC16C54 single-chip microcomputer as the controller, and it is very easy to use: just connect a telephone line to the loudspeaker through the controller, and you can rem...[Details]
We know that the inverter consists of two parts: the main circuit and the control circuit. Due to the nonlinearity of the main circuit (switching action), the inverter itself is a source of harmoni...[Details]
Motors are important products that convert electrical energy into mechanical energy to achieve automation, and they are widely used in industrial control, medical electronics, white a...[Details]
The TPS92210 is a single-stage LED lighting pulse width modulation (PWM) controller. The TRIAC dimmable solution not only regulates the LED current, but also achieves a power factor close to 1. The...[Details]
To understand how and why OLED power supply affects display image quality, you must first understand OLED display technology and power supply requirements. This article will explain the latest OLED...[Details]
introduction
Incandescent bulbs can emit a variety of light, but in specific applications, only green, red, and yellow light are usually needed - such as traffic lights. If an incand...[Details]
Car lights, whether headlights, fog lights or tail lights, play an important role in driving safety. However, the material of the car lights determines that the probability of damage in a collision...[Details]