• over voltage, over current, and short circuit protections
• UL/cUL, RCM, CCC, and PSE safety approvals
• certified to 60950-1 and 62368-1 standards
MODEL
SMI18-5
SMI18-5.9
SMI18-9
SMI18-12
SMI18-15
SMI18-18
SMI18-24
Notes:
output
voltage
(Vdc)
output
current
max
(A)
output
power
max
(W)
ripple
and noise
1
max
(mVp-p)
efficiency
level
2
5
5.9
9
12
15
18
24
3
3
2.2
1.6
1.3
1.1
0.8
15
17.7
19.8
19.2
19.5
19.8
19.2
100
100
100
120
150
180
240
VI
VI
VI
VI
VI
VI
VI
1. At full load, nominal input, 20 MHz bandwidth oscilloscope, each output terminated with 0.1 μF multilayer ceramic and 10 μF low ESR electrolytic capacitors.
2. CoC Tier 2 compliant
PART NUMBER KEY
SMI18
-
XX
-
X
-
XXX
-
CXX
Base Number
Output Voltage
Blades:
V = North America, Europe, United Kingdom,
Australia, and China blade included
N = North America blade included
E = Europe blade included
B = United Kingdom blade included
A = Australia blade included
C = China blade included
K = No blades included
Reserved for Custom
Configurations
DC Plug Type:
XXX = See output plug options
on page 4 for more details
cui.com
For more information, please visit the
product page
|
For information on related products, view
Dc Power Connectors
CUI Inc
│
SERIES:
SMI18
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
08/31/2018
│
page
2 of 5
INPUT
parameter
voltage
frequency
current
inrush current
leakage current
no load power consumption
at 230 Vac
at 100 Vac, full load, 25°C, cold start
at 230 Vac, full load, 25°C, cold start
conditions/description
min
90
47
typ
max
264
63
0.48
50
60
0.25
0.075
units
Vac
Hz
A
A
A
mA
W
OUTPUT
parameter
regulation
hold-up time
conditions/description
5 Vdc output model
all other models
at full load
10
min
typ
±6
±5
max
units
%
%
ms
PROTECTIONS
parameter
conditions/description
output shut down
5 Vdc output model
5.9 Vdc output model
9 Vdc output model
12 Vdc output model
15 Vdc output model
18 Vdc output model
24 Vdc output model
output shut down, auto recovery
5 Vdc output model
5.9 Vdc output model
9 Vdc output model
12 Vdc output model
15 Vdc output model
18 Vdc output model
24 Vdc output model
output shut down, auto recovery
min
typ
max
12
12
16
22
32
32
45
7
6
5
5
4
4
2.5
units
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
A
A
A
A
A
A
A
over voltage protection
over current protection
short circuit protection
SAFETY & COMPLIANCE
parameter
isolation voltage
isolation resistance
safety approvals
EMI/EMC
MTBF
RoHS
conditions/description
input to output at 10 mA for 1 minute
input to output at 500 Vdc
UL/cUL (60950-1, 62368-1), RCM, CCC, PSE
FCC Part 15B Class B, CE
as per Telcordia SR-332, 25°C
yes
300,000
hours
10
min
typ
3,000
max
units
Vac
MΩ
ENVIRONMENTAL
parameter
operating temperature
storage temperature
operating humidity
storage humidity
non-condensing
non-condensing
conditions/description
min
0
-20
20
10
typ
max
40
80
80
90
units
°C
°C
%
%
cui.com
For more information, please visit the
product page
|
For information on related products, view
Dc Power Connectors
CUI Inc
│
SERIES:
SMI18
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
08/31/2018
│
page
3 of 5
MECHANICAL
parameter
dimensions
inlet plug
weight
conditions/description
75 x 35.8 x 65.6
interchangeable blades (North America, Europe, UK, Australia, China)
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
I got an error when using DialogBox() in WINCE6.0. In its message function, only one statement was executed and then it went to other messages. What is the reason? Thank you!...
I installed a program on my PDA via an SD card, and the directory in the program file is \\Storage Card\. But after the installation and restart, the program prompts that it cannot find the SD card. I...
AC Characteristics
Although we are discussing DC power supplies, the output of these supplies is not pure DC. There will be some AC component in the output. For some applications, a large AC component...
Well, the effect is here. For the novice of screen clicking, it is not so smooth. The main effect is as follows
Failure 1: The height and width are wrongFailure 2: Colors are invertedFailure 3: The X-...
While using op amps, I found that there are many different processes, such as CMOS op amps, JFET input op amps, and so on.
I hope someone can share: What are the processes used in op amps, and what im...
SinoWise's SH66xx series 4-bit microcontrollers have the characteristics of fast speed, low power consumption, simple structure, easy to use, and high cost performance. They are widely used in remo...[Details]
Project Overview
The micro urine analyzer we designed can detect ten parameters of urine, including white blood cells, nitrite, urobilinogen, protein, pH value, occult blood, specific g...[Details]
How can we get the highest performance from an A/D converter? The obvious answer is to use good design and board layout, but there are other techniques that can be used to improve performance. We can ...[Details]
Microelectromechanical systems (MEMS) are gradually entering the consumer, industrial, medical, automotive and computer application markets. Moreover, we cannot ignore their steady progress in the ins...[Details]
Overview
PS pressure sensor is an electronic pressure sensor made of semiconductor diaphragm structure. It can convert the physical quantity of air pressure into electrical signals and detect ...[Details]
Preface
Sleep apnea is a very common sleep breathing disease. According to research, about 24% of adult men and 9% of adult women, or more than 2 million people, suffer from this disease ...[Details]
The 21st century is the century of life and health. The rapid progress of life sciences continues to promote human understanding of their own health and diseases. How to develop innovative medical ele...[Details]
This article discusses how to use an ultra-low-power RF transceiver chip from Zarlink Semiconductor for pacemakers, neurostimulators, drug pumps, and other such implantable medical devices t...[Details]
With the rapid development of digital technology, various digital display screens have emerged, including LED, LCD, DLP, etc. There are various control systems for various digital large screens, in...[Details]
Controller Area Network (CAN) is a type of fieldbus. It is a serial communication network that effectively supports distributed control or real-time control and is recognized as one of the most pro...[Details]
In response to a series of problems caused by the backwardness of traditional water meters, the Ministry of Construction of China has proposed the requirement of "three meters per household" for ur...[Details]
Lithium-ion battery is a widely used rechargeable battery. It has the advantages of high single-cell operating voltage, small size, light weight, high energy density, long cycle life, rapid full ch...[Details]
Due to the needs of medical development, in many cases, general thermometers can no longer meet the requirements of fast and accurate temperature measurement, such as measuring human body temperature ...[Details]
introduction
When we run or ride a bicycle, the vibration of our arms often makes the images displayed on the electronic devices in our hands look blurry. Long-term viewing (such as watchi...[Details]
E6601A is Agilent's new generation of comprehensive tester platform, designed to provide low-cost calibration solutions for mobile phone manufacturers. It uses an open Windows® XP platform, allowi...[Details]