Off-line systems with auto-ranging or PFC front ends, industrial and process control,
distributed power, medical, ATE, communications, defense and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Parameter
+IN to –IN voltage
PC to –IN voltage
PR to –IN voltage
SC to -OUT voltage
-Sense to -OUT voltage
Isolation voltage
IN to OUT
IN to base
OUT to base
Operating Temperature
Storage Temperature
Pin soldering temperature
Mounting torque
Rating
-0.5 to +410
-0.5 to +7.0
-0.5 to +7.0
-0.5 to +1.5
1.0
3000
1500
500
-55 to +100
-65 to +125
500 (260)
750 (390)
5 (0.57)
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
V
RMS
V
RMS
V
RMS
°C
°C
°F (°C)
°F (°C)
in-lbs (N-m)
Test voltage
Test voltage
Test voltage
M-Grade
M-Grade
<5 sec; wave solder
<7 sec; hand solder
6 each
Notes
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V300B12T250BL2
300B
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
=
- 10 to +100
- 20 to +125
C
=
- 20 to +100
- 40 to +125
T
=
- 40 to +100
- 40 to +125
H
=
- 40 to +100
- 55 to +125
M
=
- 55 to +100
- 65 to +125
B
Output Power
P
OUT
100W
100W, 150W
150W, 200W
200W
150W, 250W
150W, 250W
150W, 250W
150W, 250W
150W, 250W
150W, 250W
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
2
= 2V
3V 3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
V
OUT
2V
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
Finish
Pin Style
Tin/Lead
Blank:
Short
Tin/Lead
L:
Long
Gold
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
300V Mini Family
Page 1 of 14
Rev 9.6
06/2017
vicorpower.com
800 927.9474
300V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
147.4
378.7
174.6
152.8
393.8
412.6
1.2
Min
180
Typ
300
Max
375
400
178.2
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
<100ms
Notes
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
2V
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
-0.5 to 3.1
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.1
-0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 9.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20264)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.16
0.14
8.0
1.9
83
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
300V Mini Family
Page 2 of 14
Rev 9.6
06/2017
vicorpower.com
800 927.9474
300V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
3.1
(89.3)
3.5
(99.6)
100
3000
1500
500
10
3.5
(100.3)
3.9
(110.6)
115
cURus, cTÜVus, CE
3.9
(111.3)
4.3
(121.6)
Min
Typ
Max
0.5
Unit
V
DC
Vrms
Vrms
Vrms
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
300V Mini Family
Page 3 of 14
Rev 9.6
06/2017
vicorpower.com
800 927.9474
300V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
2
V
OUT
, 100W (e.g. S300B2C100BL, V300B2C100BL)
Parameter
Efficiency
S300B2C100BL (enhanced efficiency)
V300B2C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
81.0
73
2.7
Typ
83.0
74
120
2.8
3.8
±0.02
57.5
57.5
Max
Unit
%
150
2.9
4
±0.2
50
70
70
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
51
35
3.3
V
OUT
, 150W (e.g. S300B3V3C150BL, V300B3V3C150BL)
Parameter
Efficiency
S300B3V3C150BL (enhanced efficiency)
V300B3V3C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
80.5
79.5
4.14
Typ
84.5
80.6
160
4.3
4.6
±0.02
52.3
52.3
Max
Unit
%
200
4.46
6.9
±0.2
45.45
63.7
63.7
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
46.4
31.8
3.3
V
OUT
, 100W (e.g. S300B3V3C100BL, V300B3V3C100BL)
Parameter
Efficiency
S300B3V3C100BL (enhanced efficiency)
V300B3V3C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
80.8
79.5
4.14
Typ
84.5
80.8
84
4.3
4.5
±0.02
34.8
34.8
Max
Unit
%
105
4.46
4.9
±0.2
30.30
41
41
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
30.9
21.2
5
V
OUT
, 200W (e.g. S300B5C200BL, V300B5C200BL)
Parameter
Efficiency
S300B5C200BL (enhanced efficiency)
V300B5C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.2
84.0
6.03
Typ
87
85.2
80
6.25
4.2
±0.02
46
46
Max
Unit
%
100
6.47
6.3
±0.2
40
52
52
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
40.8
28
300V Mini Family
Page 4 of 14
Rev 9.6
06/2017
vicorpower.com
800 927.9474
300V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
5
V
OUT
, 150W (e.g. S300B5C150BL, V300B5C150BL)
Parameter
Efficiency
S300B5C150BL (enhanced efficiency)
V300B5C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.8
80.9
6.03
Typ
86.5
83
198
6.25
6
±0.02
34.5
34.5
Max
Unit
%
248
6.47
9.4
±0.2
30
40.5
40.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
30.6
21
8
V
OUT
, 200W (e.g. S300B8C200BL, V300B8C200BL)
Parameter
Efficiency
S300B8C200BL (enhanced efficiency)
V300B8C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.5
83.2
9.36
Typ
86.5
84.4
280
9.7
5.5
±0.02
28.8
28.8
Max
Unit
%
350
10.1
6.5
±0.2
25
33.8
33.8
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
25.5
17.5
12
V
OUT
, 250W (e.g. S300B12C250BL, V300B12C250BL)
Parameter
Efficiency
S300B12C250BL (enhanced efficiency)
V300B12C250BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.3
86.3
13.7
Typ
89.0
87.3
150
14.3
4
±0.06
24
24
Max
Unit
%
188
14.9
6
±0.3
20.83
28.1
28.1
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
21.3
14.6
12
V
OUT
, 150W (e.g. S300B12C150BL, V300B12C150BL)
Parameter
Efficiency
S300B12C150BL (enhanced efficiency)
V300B12C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.3
85.4
13.7
Typ
88.0
86.4
240
14.3
5.7
±0.02
14.4
14.4
Max
Unit
%
300
14.9
7
±0.2
12.5
16.9
16.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
Can JLINK be used by plugging it into a computer? The first time I used JLINK, the light was flashing, but it said it could not be recognized. I don't know what the problem is. The driver has also bee...
At the beginning of 2011, major cities in China have started to implement electric vehicle subsidy policies. On the basis of national subsidies, various cities have also established relevant subsidy p...
[size=3]These days, I have seen some forum friends come to Beijing to play. After visiting the scenic spots and trying all the delicious food in the imperial capital, if you still have some time, you ...
Use the timing mode of its PCA function. Set the frequency and frequency division as required. Clear PCACL and PCACH. Set COMPL and COMPH. Set the mode to 16-bit timing with interrupt. But I can't ent...
It is only used as SPI master device, and the chip select signal of slave device is controlled by other IO pins, because there is more than one. So how to connect the SSIFss pin? Is it pulled up or pu...
1 Introduction
With the acceleration of the pace of urban modernization, society has higher requirements for urban road lighting and urban lighting projects. The state has clearly required tha...[Details]
When choosing a laptop battery, you should consider several factors, such as power, appearance, and quality.
Regarding power, we often see that a manufacturer uses values such as the number ...[Details]
Battery life is critical for portable applications. For applications such as smoke detectors, security devices, and thermostats, factory-installed batteries need to last for more than 10 years. The...[Details]
The data collector of the automatic weather station is generally designed based on a single-chip microcomputer or a PC/104 bus controller. It has the characteristics of good compatibility with PC, low...[Details]
From the PIC16F946 datasheet, we know that there are two ways to write values to the LCD for display:
1. Directly write the value to LCDDATA1~LCDDATA23
2. Use disconnect t...[Details]
This week, Microsoft held its 2012 Microsoft Worldwide Partner Conference (WPC) in Toronto, Canada. At the conference, Microsoft showed its new products and services to partners around the world. A...[Details]
Experimental tasks
A DS18B20 is used to form a temperature measurement system. The temperature measurement accuracy reaches 0.1 degrees. The temperature range is between -20 degrees and +50 de...[Details]
In 2012, more than half of the cars in the European, Japanese and American car markets will be equipped with color displays, navigation systems, satellite communications and other in-vehicle infota...[Details]
At present, the traffic congestion in cities is quite serious. According to relevant news reports: In China, the traffic congestion has expanded from megacities such as Beijing, Shanghai, and Guangzho...[Details]
With the rapid development of wireless
digital communication
, more challenges have been raised for integrated circuit design and testing. In the product design stage, in order to ensure
t...[Details]
0 Introduction
Ultrasonic waves
are mechanical waves with a frequency of more than 20KHz, and the propagation speed in the air is about 340 m/s (at 20°C). Ultrasonic waves can be gene...[Details]
The above is to use MB1404 as a stereo composite signal transmitter. You can use the internal high-frequency amplifier and oscillator or not! According to my experience, I still recommend beginners...[Details]
The launch of Shenzhou IX is imminent, and Tiangong is welcoming visitors again. Yesterday, Professor Fu Qiang, Vice President of the Institute of Science and Industrial Technology of Harbin Instit...[Details]
0 Introduction
In order to improve the automation control of shortwave transmitters, so that they can automatically process from far to near, the technicians here use the ICS system to complete the ...[Details]
1 Embedded Systems
Embedded System refers to a collection of computer hardware and software with specific functions or purposes, which is divided into embedded software system and embe...[Details]