MMB50A-6

Description
Switching Power Supplies 50W 15V 1.7A AC-DC Power Supply
CategoryPower/power management   
File Size339KB,5 Pages
ManufacturerCosel
Download Datasheet Parametric View All

MMB50A-6 Online Shopping

Suppliers Part Number Price MOQ In stock  
MMB50A-6 - - View Buy Now

MMB50A-6 Overview

Switching Power Supplies 50W 15V 1.7A AC-DC Power Supply

MMB50A-6 Parametric

Parameter NameAttribute value
Product CategorySwitching Power Supplies
ManufacturerCosel
RoHSDetails
ProductSwitching Supplies
Output Voltage-Channel 115 V
Output Voltage-Channel 215 V
Number of Outputs2 Output
Output Power50 W
Open Frame/EnclosedOpen Frame
Input Voltage85 VAC to 132 VAC/110 VDC to 170 VDC
Output Current-Channel 11.7 A
Output Current-Channel 21.7 A
Commercial/MedicalCommercial
Isolation Voltage2 kV
Mounting StyleChassis
Length155 mm
Width36 mm
Height93 mm
Input Frequency47 Hz to 440 Hz
Load RegulationRegulated
Factory Pack Quantity30
Unit Weight14.109585 oz
AC-DC Power Supplies Enclosed type
Ordering information
MMB50A
R
MMB 50A
1
2
3
-1
4
-O
1Series
name
2Output
wattage
3Output
voltage combina-
tion
4Optional
*1
C :with Coating
J :Connector type
N :with Cover
MMB
MODEL
DC OUTPUT
V1
V2
MMB50A-1
MMB50A-2
+5V 3.0A
+5V 5.0A
+12V 3.0(Peak 3.6)A +12V 2.1A
MMB50A-3
MMB50A-4
+5V 3.0A
+12V 2.1A
+24V 1.5(Peak 1.8)A +12V 2.1A
MMB50A-5
+12V 3.0A
+12V 1.5A
MMB50A-6
+15V 1.7A
+15V 1.7A
SPECIFICATIONS
MODEL
VOLTAGE[V]
ACIN 100V
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
INRUSH CURRENT[A] ACIN 100V
VOLTAGE[V]
CURRENT[A]
MINIMUM CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
RIPPLE[mVp-p]
-10 - 0
C
0 to +50
C
RIPPLE NOISE[mVp-p]
-10 - 0
C
TEMPERATURE REGULATION[mV] 0 to +50
C
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
INPUT-CASE, OUTPUT
OUTPUT-CASE
OUTPUT-OUTPUT(V1-V2)
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
MMB50A-1
MMB50A-2
AC85 - 132 1
f
or DC110 - 170
1.4typ (Io=100%)
47 - 440 or DC
75typ
72typ
20typ (Io=100%) (At cold start)
MMB50A-3
MMB50A-4
MMB50A-5
MMB50A-6
INPUT
75typ
76typ
76typ
76typ
+15
1.7
0
60max
120max
120max
160max
150max
180max
150max
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
+5
+12
+5
+12
+5
+24
+12
+12
+12
+12
+15
(Peak3.6) 5
(Peak1.8) 2.1
3
2.1
3
1.5
2.1
3
1.5
1.7
3
0
0
0
0
0
0
0
0
0
0
0
20max 48max 20max 48max 20max 96max 48max 48max 48max 48max 60max
40max 100max 40max 100max 40max 150max 100max 100max 100max 100max 120max
80max 120max 80max 120max 80max 120max 120max 120max 120max 120max 120max
140max 160max 140max 160max 140max 160max 160max 160max 160max 160max 160max
120max 150max 120max 150max 120max 150max 150max 150max 150max 150max 150max
160max 180max 160max 180max 160max 180max 180max 180max 180max 180max 180max
50max 120max 50max 120max 50max 240max 120max 120max 120max 120max 150max
100max (ACIN 85V, Io=100%)
15typ (ACIN 85V, Io=100%) 25typ (ACIN 100V, Io=100%)
4.5 - 5.5 Fixed
4.5 - 5.5 Fixed
4.5 - 5.5 Fixed
10.8 - 13.2 Fixed
10.8 - 13.2 Fixed
13.5 - 16.5
11.64 - 12.36
xx
11.64 - 12.36
xx
23.28 - 24.72
xx
11.64 - 12.36
xx
11.64 - 12.36
xx
xx
Works at over 105% of rating (V2 works at peak current) and recovers automatically
Works at 115 - 140% of rating
AC2,000V 1minute, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, DC500V 50M
W
min (At Room Temperature)
AC100V 1minute, DC100V 50M
W
min (At Room Temperature)
-10 to +65
C
, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet)
-25 to +75
C
, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 30minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL Complies with DEN-AN
Complies with FCC-B
Fixed
14.55 - 15.45
max
*1
Please contact us about safety approvals for the model with option.
*
Series/Parallel operation with other model is not possible.
*
Derating is required when operated with case cover.
MMB-2
MOSFET Power Loss Calculation
I saw TI's web calculation page is very goodIf you need it, you can try it [url]https://webench.ti.com/wb5/FETs_Selection/FETPBWizard.jsp?run=Y[/url]...
dontium Analogue and Mixed Signal
Design of Data Storage System Based on SensorTile - Software Part 1
Continuing from the previous post, read the .tsv file that records sensor data through labvIEW - STMicroelectronics AMG SensorTile Development Competition - Electronic Engineering World - Forum [url=h...
suoma MEMS sensors
Input Bias Current of CMOS and JFET Amplifiers
[p=16, null, left][color=rgb(51, 51, 51)][font=Arial, Helvetica, sans-serif, 宋体][size=12px]We choose CMOS and JFET input op amps, usually because of their low input bias current (IB). But we'll give y...
wstt Microcontroller MCU
How does the Cortex-M4 EPI operate on unaddressed devices?
RT, Zhaxin asks for help....
噗噗__ Microcontroller MCU
Wiring diagram of Hall current sensor
Hall current sensor is a very common sensor in our daily life, which is widely used in household appliances, smart grid, electric vehicles, wind power generation, etc. As a high-tech product, it has a...
fish001 Analogue and Mixed Signal
Help: Shell customization problem
I followed the MSDN documentation, modified the source code of the taskbar and desktop background color, and set the environment variables for compilation, but after compilation, the startup is still ...
ldrxxx Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2683  1885  2494  846  2556  55  38  51  18  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号