Industrial and process control, distributed power, medical, ATE, communications, defense
and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V24A12T400BL2
24A
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
= - 10 to +100 - 20 to +125
C
= - 20 to +100 - 40 to +125
T
= - 40 to +100 - 40 to +125
H
= - 40 to +100 - 55 to +125
M
= - 55 to +100 - 65 to +125
B
Output Power
P
OUT
200W, 264W
300W, 400W
400W
300W
300W, 400W, 500W
300W, 400W
300W, 400W, 500W
300W, 400W, 500W
300W, 400W
300W, 400W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
3V3
= 3.3V
5
= 5V
6.5
= 6.5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
V
OUT
3.3V
5V
6.5V
8V
12V
15V
24V
28V
36V
48V
24V Maxi Family
Page 1 of 15
Rev 6.8
06/2017
vicorpower.com
800 927.9474
24V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
14.8
36.3
17.5
15.3
37.8
39.6
4.0
Min
18
Typ
24
Max
36
50
17.9
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
Notes
These modules will operate at up to 75% of rated power down
to 16V
IN
after start up at >18V
IN
<100ms
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to -OUT, +Sense to -OUT – Absolute Maximum Ratings
3.3V
5V
6.5V
8V
12V
15V
24V
28V
36V
48V
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 9.0
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.2
-0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 10.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20263)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.08
0.07
4.9
1.1
165
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
24V Maxi Family
Page 2 of 15
Rev 6.8
06/2017
vicorpower.com
800 927.9474
24V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
6.5
(184.3)
7.4
(209.3)
100
3000
1500
500
10
7.3
(207.5)
8.2
(232.5)
115
cURus, cTÜVus, CE
8.1
(230.7)
9.0
(255.7)
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
24V Maxi Family
Page 3 of 15
Rev 6.8
06/2017
vicorpower.com
800 927.9474
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3V
OUT
, 264W (e.g. S24A3V3C264BL, V24A3V3C264BL)
Parameter
Efficiency
S24A3V3C264BL (enhanced efficiency)
V24A3V3C264BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.0
80.0
4.14
Typ
86.0
81.4
75
4.3
8
±0.02
92
92
Max
Unit
%
94
4.46
12
±0.2
80
108
108
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
3.3V
OUT
, 200W (e.g. S24A3V3C200BL, V24A3V3C200BL)
Parameter
Efficiency
S24A3V3C200BL (enhanced efficiency)
V24A3V3C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.0
73.9
4.48
Typ
86.0
79.9
43
4.65
6.2
±0.02
69.7
69.7
Max
Unit
%
54
4.82
10
±0.2
60.6
81.9
81.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.8
42.4
5V
OUT
, 400W (e.g. S24A5C400BL, V24A5C400BL)
Parameter
Efficiency
S24A5C400BL (enhanced efficiency)
V24A5C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.0
80.0
6.03
Typ
86.5
84.5
152
6.25
6.8
±0.02
92
92
Max
Unit
%
190
6.47
10.1
±0.25
80
104
104
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
5V
OUT
, 300W (e.g. S24A5C300BL, V24A5C300BL)
Parameter
Efficiency
S24A5C300BL (enhanced efficiency)
V24A5C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.5
82.5
6.03
Typ
84.4
84.4
120
6.25
7.2
±0.02
69
69
Max
Unit
%
150
6.47
8.8
±0.2
60
81
81
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.2
42
24V Maxi Family
Page 4 of 15
Rev 6.8
06/2017
vicorpower.com
800 927.9474
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
6.5V
OUT
, 400W (e.g. S24A6V5C400BL, V24A6V5C400BL)
Parameter
Efficiency
S24A6V5C400BL (enhanced efficiency)
V24A6V5C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
85.0
85.0
7.7
Typ
86.1
86.1
220
7.98
9.2
±0.02
70.7
70.7
Max
Unit
%
275
8.26
10.5
±0.2
61.5
83.1
83.1
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
62.7
43
8V
OUT
, 300W (e.g. S24A8C300BL, V24A8C300BL)
Parameter
Efficiency
S24A8C300BL (enhanced efficiency)
V24A8C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.6
85.6
9.36
Typ
86.5
86.5
215
9.7
8.7
±0.02
43.1
43.1
Max
Unit
%
269
10.1
13.9
±0.2
37.5
50.7
50.7
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
38.2
26.2
12V
OUT
, 500W (e.g. S24A12C500B, V24A12C500BL)
Parameter
Efficiency
S24A12C500B (enhanced efficiency)
V24A12C500BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.7
86.0
13.8
Typ
88.2
87.5
272
14.3
10.8
±0.02
47.9
47.9
Max
Unit
%
340
14.8
12.0
±0.2
41.67
56.3
56.3
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
42.5
29.2
12V
OUT
, 400W (e.g. S24A12C400BL, V24A12C400BL)
Parameter
Efficiency
S24A12C400BL (enhanced efficiency)
V24A12C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.0
87.0
13.7
Typ
89.5
88.3
250
14.3
6.8
±0.02
38.4
38.4
Max
Unit
%
320
14.9
10.2
±0.2
33.33
43.5
43.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
Just calculated the same number both ways, but in numpy, it gives an error[[ 0.910221324013388510820732335560023784637451171875]][[-0.9102213240133882887761274105287156999111175537109375]]This number ...
[High Precision Laboratory] Sensor Technology: Temperature Sensor : https://training.eeworld.com.cn/course/5480TI Precision Labs (TIPL) is the most comprehensive online classroom for analog signal cha...
sprintf(DisTempData,"%d",temp); //Print variable LCD_Write_String(1,1,DisTempData); //Display to LCD screen temp is a char type variable DisTempData[] is a char array... But the problem is that 20 is ...
[size=4]TI experts explain the basics of battery power, [/size][b][size=4]Battery power monitoring basics[/size][/b][size=4][color=#ff0000][b]Wonderful courses are all in the eeworld forum TI classroo...
BackgroundTheapplication field of portable power is broad and diverse. Products range from wireless sensor nodes with an average power consumption of only a few μW to vehicle-mounted medical or data a...
[align=left] [/align][align=left][b]Solder mask[/b][/align][align=left]The solder mask refers to the part of the board that needs to be coated with green paint. Because it is a negative film output, t...
As the number of cars increases, environmental pressures are also increasing. At this time, some people are saying that new energy vehicles are energy-efficient and environmentally friendly, and ar...[Details]
With the gradual popularization of new energy vehicles in recent years, more and more people have been able to access and purchase electric vehicles. The structure of electric vehicles is composed ...[Details]
On August 21, it was reported that Intel's new generation of AI chip Jaguar Shores was recently exposed for the first time.
According to photos shared by Andreas Schilling, the Jaguar Shores t...[Details]
In camera and display systems, the demand for high-performance and low-power data interfaces is driving continuous technological evolution. The evolution of MIPI D-PHY and MIPI C-PHY clearly ...[Details]
Using an electronic load is like thinking of it as a resistor that dissipates the power supply's output. The most straightforward mode is the CR constant resistance mode. In this mode, by setting a...[Details]
Servo motors, also known as actuator motors, serve as actuators in automatic control systems, converting received electrical signals into angular displacement or angular velocity output on the moto...[Details]
Most electric vehicles currently lack a gearbox, only a single-speed reduction gearbox. This includes Teslas, but that doesn't mean electric vehicles don't need a gearbox. Thanks to the constant to...[Details]
Since the beginning of summer, high temperatures have continued to intensify, and the national electricity load has frequently broken records. The latest data from the National Energy Administratio...[Details]
In the laboratory material transfer scenario, Jingshi Fuhe has solved core problems such as precise grasping, environmental adaptability and process collaboration through technological innovation...[Details]
The functions are still useless. When will it be able to be clearly distinguished from smartphones?
Most consumers categorize their smartwatch purchases as a desire to try something new. A sig...[Details]
Simulation is an essential tool to help robots learn new skills such as perception (understanding the world from camera images), planning (developing a sequence of actions to solve a problem), and ...[Details]
Once the half-year data on power batteries came out, the situation became clearer.
According to the latest data from South Korean research firm SNE Research, global installed capacity of...[Details]
Flashing the firmware of a fuel-powered vehicle is used to increase vehicle power, but why can't this be done on electric vehicles? The reason electric vehicles can't be flashed is to protect the v...[Details]
Time delay relays play a crucial role in electrical control systems. Upon receiving a trigger signal, they control the on/off switching of circuits at preset intervals, providing precise timing con...[Details]
On August 8, AB Dynamics launched ClearTrack, a fully integrated object detection system for testing unmanned robot-controlled vehicles. The system was jointly developed with its sister company ABD...[Details]