PLE**HSZ Specification
Specifications<AC/DC>
PLEY**HSZ-U
240WATTS(Peak 300-360W)/SINGLE
Output Characteristic
Output Voltage [V]
Output Current [A]
Voltage Adjust Range
Ripple and Noise [mVp-p](maximum) *3
Regulation
Statistic Line Regulation [mV](maximum)
Statistic Load Regulation [mV](maximum)
Temperature Coefficient *4
Drift[mV](maximum) *5
Dynamic Load Regulation [mV](typical) *6
Recovery Time *6
Rise up time
Hold up time
Functions
Overcurrent Protection [A](minimum)
Overvoltage Protection 110% of Rated
Output Voltage[V]
?
Remote Sense
Remote On/Off
Environmental
Operating Temperature *7
Operating Humidity
Storage Temperature
Storage Humidity
Withstanding Voltage
Model
PLEY12HSZ-U
PLEY24HSZ-U
PLEY36HSZ-U
12
24
36
18.0(Peak 25.0)
10.0(Peak 15.0)
6.8(Peak 10.0)
+/- 10% of Rated Output Voltage(at no load within the input range)
220
340
460
96
108
75
360
192
216
0.03%/?
135
720
0.5mS(typical)
500mS(maximum) at 25
20mS(minimum) at 25? and rated input/output
and rated input/output
?
288
324
195
1080
25.15
13.2
Current Limiting with automatic recovery
16.2
Output shutdown(to reset,leave 1minute after shut-off)
26.4
not available
option
0 to +50 /enclosed type: -5 to +40
30 to 85%RH(non-condensing)
?
-20 to +85 Celsius
?
10 to 85%RH(non-condensing)
Primary-Secondary AC3,000V for 1minute
Primary-Frame Ground AC3,000V for 1minute
Secondary-Frame Ground AC500V for 1minute
10.5
39.6
Isolation Resistance
Vibration
Shock
Cooling
Leakage Current
Line Conducted Noise
Safety
Primary-Secondary-Frame Ground 50MΩ(minimum) by DC500V insulation tester
5-10Hz:10mm double amplitude,10-55Hz:19.6m/s
2
,20minutes' period for 60minutes each along X,Y,Z axes(non-operating)
Weight (typical)
MTBF [H]
Switching Frequency[kHz](typical)
Conditions:
*1 at cold start
*2 at AC115/20V and at 25 Celsius
*3 measured by a bayonet probe at output connector at 0 to 100MHz bandwidth
*4 at 0 to +50 Celsius
*5 for 7hour period after 1hour warm-up at 25 Celsius and rated input/output
*6 when output current changed from 25% and 75% of rated output current rapidly at AC115/230V input
*7 safety approved at 25 Celsius
294m/s
2
Convection
1mA(maximum) at 25 ,rated input/output and rated input frequency
Built to meet VDE0871 Class A
?
Built to meet FCC Part15-B Class A
UL: UL1950
CUL: CSA C22.2 No950
VDE: EN60950,IEC950,VDE0805
1,130g/enclosed type:1,260g
480,000
90
ETA-USA Tel:
408-778-2793
Fax:
408-779-2753
e-mail: