EEWORLDEEWORLDEEWORLD

Part Number

Search

38-D126J1

Description
POWER/SIGNAL RELAY, SPST, MOMENTARY, 5000mW (COIL), PANEL MOUNT
CategoryMechanical and electronic products    relay   
File Size232KB,2 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric View All

38-D126J1 Overview

POWER/SIGNAL RELAY, SPST, MOMENTARY, 5000mW (COIL), PANEL MOUNT

38-D126J1 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresCOIL OPERATE VOLTAGE(AC): 305 V, COIL RELEASE VOLTAGE(AC): 60 V
body width46.2 mm
body height46.2 mm
Body length or diameter51.6 mm
Coil current (AC) maximum value0.03 A
Coil power5000 mW
Coil resistance15200 Ω
Maximum coil voltage (AC)452 V
Coil/Input Power TypeAC
Contact/Output Power TypeAC
Electrical life250000 Cycle(s)
Manufacturer's serial number38
Installation featuresPANEL MOUNT
physical size51.6mm X 46.2mm X 46.2mm
GuidelineUL
Relay actionMOMENTARY
Relay functionSPST
Relay typePOWER/SIGNAL RELAY
surface mountNO
Termination typeQUICK CONNECT
Base Number Matches1
Catalog 1308242
Issued 3-03
PRODUCTS UNLIMITED
38
series
Potential Motor Starting Relay
1-pole, 35A, Normally Closed
AC Coil
File E83865
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• Single-pole, normally closed relay used extensively in HVAC applications.
• Variety of mounting positions and brackets.
• Convenient 0.250” (6.35 mm) quick connect terminals.
• Custom-built to meet customer requirements.
Coil Data @ 25°C
Voltage:
130, 170, 214, 256, 336, 395, 420 and 495 VAC, 60 Hz.
Nominal Sealed Power:
5 VA).
Insulation Class:
UL Class B (130°C).
Duty Cycle:
Continuous.
Contact Data @ 25°C
Arrangements:
Normally-Closed.
Materials:
Silver cadmium oxide.
Maximum Rating:
35A inductive @ 277VAC, 0.5 power factor (Break only.)
Expected Life:
750,000 ops, mechanical.
250,000 ops., breaking rated load.
Mechanical Data
Termination:
0.250” (6.35 mm) quick connects (single or dual, model
dependent). Terminals #4 & #6 are dummies for customer
convenience.
Mounting Position:
Each model is calibrated for its specified mounting
position. Pick-up voltage may vary if relay is mounted
in positions other than specified.
Weight:
5.76 oz. (163.8 g) approximately
Initial Dielectric Strength
Initial Breakdown Voltage:
1,554 VAC @ 60 Hz. between live parts and
exposed non-current carrying metal parts.
Ordering Information
Typical Part No.
B
38
-A
144
C
3
000
1. Series:
38 = 1-pole, normally-closed, potential motor starting relay
2. Wiring and Terminal Type (number of QCs at given base locations):
A = 2 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 2 @ loc. 6.
D = 2 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
M = 2 @ loc. 1, 2 @ loc. 2, 2 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
R = 1 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 1 @ loc. 5 and 0 @ loc. 6.
S = 1 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
T = 2 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
Y = 1 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
3. Coil Rating and Calibration:
000-999 = See table on following page for details.
4. Mounting Bracket Style:
C, D, F or J = See drawings below for details.
C
1.59
(40.39)
#8-32
UNC-2B THD.
D
F
J
.500
(12.7)
#8-32
UNC-2B THD.
1.00
(25.4)
1.563
(39.7)
5. Mounting Position:
1, 2, 3, 4, 5 & 6 = See drawings below for details. NOTE: Devices calibrated in specified mounting position only.
1
2
3
4
5
6
6. Customer ID Suffix:
000-999 = Factory assigned customer ID
Standard part numbers listed below are more likely to be available from stock.
Custom parts only.
Dimensions are shown for
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
818
reference purposes only.
P89LPC932 Errata
Give a typical example...
rain RF/Wirelessly
This is other people's life, I can't envy it!
In the same flowers, butterflies choose to fly aimlessly, while bees choose to collect honey tirelessly. Under the same blue sky, in the same university, some people like to study, going in and out of...
zhangdaoyu Robotics Development
How to read the serial port converted from prolific usb to serial port
Does it also use createfile to read? Is it the same as the normal com feature?...
laobushi Embedded System
Designed a Simon game ruler with 4 LEDs and switches
The simon game is a memory game. After the machine is turned on, an LED will light up randomly. The player needs to press the switch next to the LED that lit up. Then the machine will randomly light u...
cybertovsky Microcontroller MCU
AT89C2051 and 74LS164....Emergency...
Ask the experts: As shown in the picture, is the display circuit connected in this way wrong? The teacher said that RXD cannot be output, TXD cannot be used as the CLOCK signal of 74LS164, and the AB ...
starli521 51mcu
Question about reading FLASH data
I downloaded NK to NOR FLASH in BOOTLOADER. Now I want to print out the written data. Can I directly access the address of FLASH? I tried and found that I couldn't read it (all 0). I still need to wri...
leo2222 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2650  2401  874  2701  2200  54  49  18  55  45 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号