Z: Tape and reel packing (Picked from the 8/9/10/12-pin side)
Note: In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay.
TYPES
1. Standard (B.B.M.) type/Surge breakdown voltage (between contact and coil) 2,500 V/ Breakdown voltage (between open
contacts) 1,000 V
1) Standard PC board terminal
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2-1.5V
TXD2-3V
TXD2-4.5V
TXD2-5V
TXD2-6V
TXD2-9V
TXD2-12V
TXD2-24V
1 coil latching
Part No.
TXD2-L-1.5V
TXD2-L-3V
TXD2-L-4.5V
TXD2-L-5V
TXD2-L-6V
TXD2-L-9V
TXD2-L-12V
TXD2-L-24V
2 Form C
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
2) Surface-mount terminal
(1) Tube packing
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2S
TXD2S
TXD2S
TXD2S
TXD2S
TXD2S
TXD2S
TXD2S
-1.5V
-3V
-4.5V
-5V
-6V
-9V
-12V
-24V
1 coil latching
Part No.
TXD2S
TXD2S
TXD2S
TXD2S
TXD2S
TXD2S
TXD2S
TXD2S
-L-1.5V
-L-3V
-L-4.5V
-L-5V
-L-6V
-L-9V
-L-12V
-L-24V
2 Form C
: For each surface-mount terminal identification, input the ollowing letter. SA type: A, SS type: S
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
ASCTB19E 201209-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e
TX-D
(2) Tape and reel packing
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2S -1.5V-Z
TXD2S -3V-Z
TXD2S -4.5V-Z
TXD2S -5V-Z
TXD2S -6V-Z
TXD2S -9V-Z
TXD2S -12V-Z
TXD2S -24V-Z
1 coil latching
Part No.
TXD2S -L-1.5V-Z
TXD2S -L-3V-Z
TXD2S -L-4.5V-Z
TXD2S -L-5V-Z
TXD2S -L-6V-Z
TXD2S -L-9V-Z
TXD2S -L-12V-Z
TXD2S -L-24V-Z
2 Form C
: For each surface-mount terminal identification, input the ollowing letter. SA type: A, SS type: S
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available.
2. Please add “-1” to the part number for AgPd contacts (low level load). (Ex. TXD2SA-1.5V-1-Z)
2. M.B.B type/Surge breakdown voltage (between contact and coil) 2,500 V/ Breakdown voltage (between open contacts)
1,000 V
1) Standard PC board terminal
Contact arrangement
Nominal coil voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Single side stable
Part No.
TXD2-2M-1.5V
TXD2-2M-3V
TXD2-2M-4.5V
TXD2-2M-5V
TXD2-2M-6V
TXD2-2M-9V
TXD2-2M-12V
TXD2-2M-24V
2 Form C
2) Surface-mount terminal
(1) Tube packing
Contact arrangement
Nominal coil voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2S -2M-1.5V
TXD2S -2M-3V
TXD2S -2M-4.5V
TXD2S -2M-5V
TXD2S -2M-6V
TXD2S -2M-9V
TXD2S -2M-12V
TXD2S -2M-24V
2 Form C
: For each surface-mount terminal identification, input the ollowing letter. SA type: A, SS type: S
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
(2) Tape and reel packing
Contact arrangement
Nominal coil voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2S
TXD2S
TXD2S
TXD2S
TXD2S
TXD2S
TXD2S
TXD2S
-2M-1.5V-Z
-2M-3V-Z
-2M-4.5V-Z
-2M-5V-Z
-2M-6V-Z
-2M-9V-Z
-2M-12V-Z
-2M-24V-Z
2 Form C
: For each surface-mount terminal identification, input the ollowing letter. SA type: A, SS type: S
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Types designed to withstand strong vibration caused, for example, by the use of terminal cutters, can also be ordered.
However, please contact us if you need parts for use in low level load. (Ex. TXD2SA-2M-1.5V-1-Z)
2. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available.
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e
ASCTB19E 201209-T
TX-D
3. Standard (B.B.M.) type/Surge breakdown voltage (between contact and coil) 6,000 V/ Breakdown voltage (between open
contacts) 1,000 V
1) Standard PC board terminal
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2-1.5V-6
TXD2-3V-6
TXD2-4.5V-6
TXD2-5V-6
TXD2-6V-6
TXD2-9V-6
TXD2-12V-6
TXD2-24V-6
1 coil latching
Part No.
TXD2-L-1.5V-6
TXD2-L-3V-6
TXD2-L-4.5V-6
TXD2-L-5V-6
TXD2-L-6V-6
TXD2-L-9V-6
TXD2-L-12V-6
TXD2-L-24V-6
2 Form C
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-7” to the end of the part number for AgPd contacts (low level load).
2) Surface-mount terminal
(1) Tube packing
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2S -1.5V-6
TXD2S -3V-6
TXD2S -4.5V-6
TXD2S -5V-6
TXD2S -6V-6
TXD2S -9V-6
TXD2S -12V-6
TXD2S -24V-6
1 coil latching
Part No.
TXD2S -L-1.5V-6
TXD2S -L-3V-6
TXD2S -L-4.5V-6
TXD2S -L-5V-6
TXD2S -L-6V-6
TXD2S -L-9V-6
TXD2S -L-12V-6
TXD2S -L-24V-6
2 Form C
: For each surface-mount terminal identification, input the ollowing letter. SA type: A, SS type: S
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-7” to the end of the part number for AgPd contacts (low level load).
(2) Tape and reel packing
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2S -1.5V-6-Z
TXD2S -3V-6-Z
TXD2S -4.5V-6-Z
TXD2S -5V-6-Z
TXD2S -6V-6-Z
TXD2S -9V-6-Z
TXD2S -12V-6-Z
TXD2S -24V-6-Z
1 coil latching
Part No.
TXD2S -L-1.5V-6-Z
TXD2S -L-3V-6-Z
TXD2S -L-4.5V-6-Z
TXD2S -L-5V-6-Z
TXD2S -L-6V-6-Z
TXD2S -L-9V-6-Z
TXD2S -L-12V-6-Z
TXD2S -L-24V-6-Z
2 Form C
: For each surface-mount terminal identification, input the ollowing letter. SA type: A, SS type: S
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available.
2. Please add “-7” to the part number for AgPd contacts (low level load). (Ex. TXD2SA-1.5V-7-Z)
ASCTB19E 201209-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e
TX-D
4. Standard (B.B.M.) type/Surge breakdown voltage (between contact and coil) 6,000 V/ Breakdown voltage (between open
contacts) 1,500 V (High breakdown voltage type)
1) Standard PC board terminal
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2-1.5V-3
TXD2-3V-3
TXD2-4.5V-3
TXD2-5V-3
TXD2-6V-3
TXD2-9V-3
TXD2-12V-3
TXD2-24V-3
1 coil latching
Part No.
TXD2-L-1.5V-3
TXD2-L-3V-3
TXD2-L-4.5V-3
TXD2-L-5V-3
TXD2-L-6V-3
TXD2-L-9V-3
TXD2-L-12V-3
TXD2-L-24V-3
2 Form C
Standard packing: Tube: 40 pcs.; Case: 800 pcs.
Note: Please add “-4” to the end of the part number for AgPd contacts (low level load).
2) Surface-mount terminal
(1) Tube packing
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2S -1.5V-3
TXD2S -3V-3
TXD2S -4.5V-3
TXD2S -5V-3
TXD2S -6V-3
TXD2S -9V-3
TXD2S -12V-3
TXD2S -24V-3
1 coil latching
Part No.
TXD2S -L-1.5V-3
TXD2S -L-3V-3
TXD2S -L-4.5V-3
TXD2S -L-5V-3
TXD2S -L-6V-3
TXD2S -L-9V-3
TXD2S -L-12V-3
TXD2S -L-24V-3
2 Form C
: For each surface-mount terminal identification, input the ollowing letter. SA type: A, SS type: S
Standard packing: Tube: 40 pcs.; Case: 800 pcs.
Note: Please add “-4” to the end of the part number for AgPd contacts (low level load).
(2) Tape and reel packing
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2SA-1.5V-3-Z
TXD2SA-3V-3-Z
TXD2SA-4.5V-3-Z
TXD2SA-5V-3-Z
TXD2SA-6V-3-Z
TXD2SA-9V-3-Z
TXD2SA-12V-3-Z
TXD2SA-24V-3-Z
1 coil latching
Part No.
TXD2SA-L-1.5V-3-Z
TXD2SA-L-3V-3-Z
TXD2SA-L-4.5V-3-Z
TXD2SA-L-5V-3-Z
TXD2SA-L-6V-3-Z
TXD2SA-L-9V-3-Z
TXD2SA-L-12V-3-Z
TXD2SA-L-24V-3-Z
2 Form C
*Only for SA type.
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available.
2. Please add “-4” to the part number for AgPd contacts (low level load). (Ex. TXD2SA-1.5V-4-Z)
It has been exactly one year since the launch of C2000 launchpad. To celebrate the rapid development of launchpad, TI is selling C2000 Piccolo LaunchPad at half price on estore. This should be the bes...
Today's review starts with the following thing. Yes, it is "Meet the MSP432P401R LaunchPad Development Kit", also known as "Quick Start Guide"Open the manual, the first thing you see is a packing list...
In WinCE6.0 system, the program receives 16-bit dot matrix data through the network and then refreshes the display on the screen. Currently, SetDIBitsToDevice is used, but the refresh speed is slow. I...
Chip model: HT48F10E, the function description has been determined: negative ion hot hair dryer, mainly in temperature control. The sensor is a thermistor, forming an RC oscillation circuit to measure...
Check the air conditioner socket, it shows the wiring is normal Check a two-pin power strip, it shows the ground wire is missing[font=微软雅黑][size=3]It is easy to carry, an external pendant, beautiful a...
Dual-mode inverters can operate both in conjunction with the grid and independently. These inverters can inject excess energy from renewable energy and storage devices into the grid, and withdraw p...[Details]
We are entering a new era where people are increasingly affordably equipped with more electronic gadgets. Electronics have become essential to our lives. For example, the average consumer now owns ...[Details]
summary
There are multiple approaches to making industrial systems more intelligent, including applying artificial intelligence (AI) technology at the edge and in the cloud to sensor...[Details]
On August 22, Lantu Motors officially launched its Lanhai Intelligent Hybrid technology via an online livestream. This intelligent hybrid technology, which integrates a full-range 800V high-voltage...[Details]
Electric vehicles' 12V batteries don't rely on a generator to power them. Only gasoline-powered vehicles rely on the engine to drive a generator to generate electricity while driving, which is used...[Details]
Permanent magnets are essential components in a wide range of household and industrial devices. They are particularly crucial in the renewable energy sector, including electric vehicle motors. Curr...[Details]
With the continuous development of the industrial automation industry, we are seeing an increasing number of intelligent devices using flexible, efficient, and precise robotic arms to p...[Details]
Industrial computers with GPUs leverage powerful parallel processing to build deep learning models to analyze and respond to optical inputs. The systems develop an understanding of visual data to i...[Details]
A patent disclosed by Ford proposes replacing traditional segmented side curtain airbags with integrated full-width side curtain airbags that span the side of the vehicle and can be deployed simult...[Details]
On August 20, Geely announced its focus on "One Cockpit". Through a unified AI OS architecture, a unified AI Agent, and a unified user ID, it will achieve an All-in-One AI cockpit, create the first...[Details]
Lightweighting of automobiles is still a relatively unfamiliar term for automobiles. With the continuous improvement of environmental protection requirements, relevant regulations have also put for...[Details]
New version helps developers build secure and trustworthy embedded systems
Shanghai, China—August 21, 2025—
QNX, a division of BlackBerry Ltd., today announced the release of QNX...[Details]
Puttshack's Trackaball uses the Nordic nRF54L15 system-on-chip (SoC) to monitor sensors and enable Bluetooth low energy connectivity, while the nPM2100 power management integrated circuit (PMIC) ...[Details]
On August 20, it was reported that the specifications of Intel's upcoming Panther Lake mobile processor appeared on the Intel GFX CI website, which mainly focuses on Intel's open source Linux drive...[Details]
Traditionally, electrical energy is transmitted primarily through wires, requiring direct physical contact between the power source and the load. With the increasing number of electrical devices in...[Details]