Motor DC energy consumption braking circuit
Source: InternetPublisher:石榴姐 Keywords: Braking circuit electric motor energy consumption braking Updated: 2020/11/22
Working principle of the circuit: In the picture, when the start button QA is pressed,
the coil of contactor 1C is energized, the motor rotates, and the
capacitor C is charged at the same time. When the TA button is pressed during parking, the contactor 1C loses power and disconnects the motor, and the capacitor C pairs the coil The highly sensitive relay K with a resistance of 3kn
is discharged, causing K to pull in, and the 2C contactor coil is powered to pull in, thereby
performing DC energy consumption braking . After a certain period of time, the capacitor C is discharged and the relay
K is released. At this time Braking ends. Selecting the capacity of capacitor C can change
the length of braking time. This circuit is simple and reliable, suitable for motors below 5 kW .
- How to use a microcontroller to control a servo motor?
- What is a 4-pin PWM header? How do 4-pin PWM fans work?
- The meaning and importance of circuit protection, common types of circuit protection
- Use your smartphone to turn on/off the power in your home
- A simple door handle touch alarm circuit
- JDB-LQ-TQ/2 motor full voltage starting circuit
- PIC microcontroller controlled remote anti-theft alarm circuit
- Homemade short circuit alarm device
- Water supply reminder after water outage
- Precious home appliance anti-theft alarm
- Pyroelectric automatic door control circuit
- fire smoke control circuit
- Photocell trigger control circuit
- Ringtone control circuit
- Directly start DC motor energy consumption braking circuit
- Forward and reverse operation short-circuit braking circuit
- Forward and reverse operation reverse braking circuit 3
- One-way operation reverse braking circuit three
- DC motor reverse braking circuit
- DC energy consumption braking circuit