High Power uses rugged and environmentally sealed (IP68) shells to protect APP
®
Powerpole
®
contacts and housings. Customer
configured SPEC Pak
™
High Power Connectors are capable of up to
260
amps and may be used anywhere a rugged and/or waterproof high
power, signal and ground interconnect solution is required.
The SPEC Pak
™
High Power shell accepts 75 to 180 amp Powerpole
®
contacts and up to 8 auxiliary contacts. The wide range of Powerpole
®
housing colors and contact sizes, coupled with the available Powerpole
®
insert holders, offers the user a wide array of design options. Wire sizes
which can accommodate a range from 24 to 3/0 AWG (0.25 to 85.0 mm²). SPEC Pak™ High Power is highly configurable with thousands of design
options in a single interconnect.
1
2
3
4
5
8
5
5 Powerpole
®
Insert Arrangement
6
7
H02
H03
H06
6 - Power Contacts
(up to 260 amps with 3/0 AWG)
7- Color Coded Powerpole
®
Housings Match Wire Colors
8 - Industry Standard Sealing (IP68) Components
• PG Gland Compatible - Size 36 and 42
• Multi-hole Glands For Use With Discrete Wires
• Single Hole Glands For Use With Jacketed Cable
1 - Chemical & UV Resistant Ruggedized Shells
• Wire to wire configurations
• Wire to Panel configurations
2 - Stainless Steel Latches
(securing plug to receptacle)
3 - IP68 Interfacial Sealing O-Ring
4 - Auxiliary Contacts
(up to 8)
5 - Powerpole® Insert Holders
(user configurable)
• H02 Arrangement - up to two PP180 & 8 auxiliaries
• H03 Arrangement - up to three PP120 & 8 auxiliaries
• H06 Arrangement - up to six PP75 & 8 auxiliaries
-2-
www.andersonpower.com
Specifications
High Power SPEC Pak
™
Shell / Components
Electrical
UL Voltage Rating (AC/DC)
Dielectric Withstanding Voltage (AC)
Operating Temperature (°C )
(°F )
Flammability Rating of SPEC Pak
™
Shells
UV Rating (equivalent)
Mechanical
600
3000
-40 to 105 *
-40 to 221
UL94 V-0
UL746C F1
Inline Receptacle
Latch
Plug
Shell/Latch Mating Cycles
Average Connect/Disconnect (lbf)
(N)
IP Rating
UL50 Sec. 36 Sealing Requirement
Crush Test per EIA-364-40B
Drop Test per UL50E
Material
1,500 Min.
28
125
IP68
Pass
Pass
Pass
PG Gland
SPEC Pak
™
- Receptacle, Plug & Holders
Latch
Latch Retainer
Holder Mount Hardware
PBT
Stainless Steel
Stainless Steel
Nickel Plated Steel
Mated Pair
High Power Plug To
Inline Receptacle
Powerpole
®
Contacts
UL Current Rating (Amperes) **
CSA (30C Rise) (Amperes) **
Voltage Rating (AC/DC)
Contact Barrel Wire Size (AWG)
(mm²)
Average Contact Resistance (milliohm)
Contact Retention Force (lbf)
(N)
Operating Temperature (°C)
(°F)
Flammability Rating
Contact Materials
Contact Plating
Mechanical
PP180
260
140
600
3/0 to 6
85 to 13.3
0.10
170
756
-20 to 105 *
-4 to 221
UL94 V-0
Copper
Silver
10,000
20
PP120
190
100
600
1/0 to 6
53.5 to 13.3
0.14
100
445
-20 to 105 *
-4 to 221
UL94 V-0
Copper
Silver
10,000
8
PP75
70
40
600
6 to 12
13.3 to 3.3
0.20
50
222
-20 to 105 *
-4 to 221
UL94 V-0
Copper
Silver
10,000
5 (Low Detent)
7 (High Detent)
Polycarbonate
PowerMod
®
5
5
600
12 to 24
4.0
3.00
8
36
-20 to 105 *
-4 to 221
UL94 V-0
Copper Alloy
Gold over Nickel
10,000
10 oz. (3N) Average
Mating Cycles - no load
Average Connect/Disconnect (lbf)
Material
Powerpole
®
Housing Material
Polycarbonate
Polycarbonate
PBT
NOTE:
-40° to 120° C (-40° to 248° F) can be achieved by using APP Chemical Resistant Powerpole
®
housing. Contact factory for more information.
Based on Panel Mount Receptacle to Plug configuration.
*
**
1. Agency approvals - TUV Pending / Patents &
Patents
Pending
www.andersonpower.com
-3-
Part Number Configurator
PART NUMBER PLAN
SPEC Pak
™
Series
(1 Fixed Character)
Shell Color
(1 Character)
Shell Style
(1 Character)
Dash
Shell Size
(mm) (3 Characters)
Insert Arrangement
(3 Characters)
S
S = SPEC Pak
™
Series
K
K = Black
2
-
095
095 = 095mm Panel Mount
Receptacle Shell
A95 = 095mm Shell, PG 36
B95 = 095mm Shell, PG 42
H02
Detailed Information
Is Available On:
H02 = PP180, 2 Pole .................... Page 7
H03 = PP120 Housing, 3 Pole ...... Page 8
H06 = PP75, 6 Pole ...................... Page 9
1 = Inline Receptacle
2 = Panel Mount Receptacle
6 = Straight Plug
9 = Environmental Receptacle Cover
9P = Environmental Plug Cover
PLUG
KIT
Powerpole
®
Holder Set
PANEL MOUNT
RECEPTACLE KIT
Panel Mount
Receptacle
Gasket
INLINE
RECEPTACLE KIT
Powerpole
®
Holder Set
COVER
KIT
IP68 Sealing
Plug Cover
Lanyard
Plug Shell
Holder
Retaining
Screws
Powerpole
®
Holder Set
Panel Mount
Receptacle
Shell With Latches
Inline Receptacle
Shell With Latches
Holder Retaining Screws
IP68 Sealing
Receptacle Cover
Holder Retaining Screws
Ordering Information
Part
Number & Description
SK6-A95H02
Ordering Information
Part
Number & Description
SK2-095H02
Ordering Information
Part
Number & Description
SK1-A95H02
Ordering Information
Part
Number & Description
SK9-095
- Plug Kit, PG 36 compatible shell with
2 pole PP180 holder
- Plug Kit, PG 36 compatible shell with
3 pole PP120 holder
- Plug Kit, PG 36 compatible shell with
6 pole PP75 holder
- Plug Kit, PG 42 compatible shell with
2 pole PP180 holder
- Plug Kit, PG 42 compatible shell with
3 pole PP120 holder
- Plug Kit, PG 42 compatible shell with
6 pole PP75 holder
- Panel Mount Receptacle Kit with
2 pole PP180 holder
- Panel Mount Receptacle Kit with
3 pole PP120 holder
- Panel Mount Receptacle Kit with
6 pole PP75 holder
- Inline Receptacle Kit, PG 36
compatible shell with, 2 pole PP180 holder
- Inline Receptacle Kit, PG 36
compatible shell with, 3 pole PP120 holder
- Inline Receptacle Kit, PG 36
compatible shell with, 6 pole PP75 holder
- Inline Receptacle Kit, PG 42
compatible shell with, 2 pole PP180 holder
- Inline Receptacle Kit, PG 42
compatible shell with, 3 pole PP120 holder
- Inline Receptacle Kit, PG 42
compatible shell with, 6 pole PP75 holder
- Receptacle Cover Kit with lanyard
- Plug Cover Kit with lanyard
SK6-A95H03
SK2-095H03
SK1-A95H03
SK9P-095
SK6-A95H06
SK2-095H06
SK1-A95H06
Component
Replacement Parts
Part
Number & Description
H1120P41
SK1-B95H02
SK6-B95H02
- #8 x 5/8 screw - Bulk Packaged
SK1-B95H03
SK6-B95H03
SK1-B95H06
SK6-B95H06
NOTE:
- Panel Mount Receptacle mounting hardware (8 each #10 or M5 screw) not included
- Recommended torque for mounting hardware is 15 to 20 in-lbf (1.7 to 2.2 N-m)
-4-
www.andersonpower.com
PART NUMBER PLAN
Wire Protection
See page 6
(4 Characters)
Housing
Arrangement
Dash
Contact
Dash
For more information see pages 7 thru 9
(1 Character)
(2 Characters)
APP Content
(3 Characters)
PS
00 = None
PS = Plastic Short
PM = Plastic Multi-hole
00
00 = None
00 - 99 = Various Gland Type
0 = Custom Configuration
A = AC Single Phase
B = AC 3 Phase, 3 Wire
E = AC 3 Phase, 4 wire
F = AC 3 phase, 5 wire
G = DC 2 Circuit, 6 wire
R = DC 1 Circuit, 2 Wire
Z = All Black
-
0
Contact
Code
00
11
12
13
14
15
16
20
21
22
23
24
25
26
27
28
29
80
81
82
83
84
85
86
87
88
89
90
91
92
93
00
-
A01
Custom
Configuration
Available in Insert
Arrangement
H06
H06
H06
H06
H06
H06
H03
H03
H03
H03
H03
H03
H03
H03
H03
H03
H02
H02
H02
H02
H02
H02
H02
H02
H02
H02
H02
H02
H02
H02
Insert Arrangement
-
H03
H06
H06
H06
H06
H02, H03
H02, H03
Wire Size
Contact
AWG
(mm²)
Custom Configuration - Use Next Section
5900
#6
13.3
5952
#8
8.4
5915
#10 to 12 5.3 to 3.3
5900 with Auxiliary #6
13.3
5952 with Auxiliary #8
8.4
5915 with Auxiliary #10 to 12 5.3 to 3.3
1323G2
1/0
1323G1
#1
1319
#2
1319G4
#4
1319G6
#6
1323G2 with Auxiliary 1/0
1323G1 with Auxiliary #1
1319 with Auxiliary #2
1319G4 with Auxiliary #4
1319G6 with Auxiliary #6
1328G2
3/0
1328G1
2/0
1382
1/0
1347
#1
1383
#2
1384
#4
1348
#6
1328G2 with Auxiliary 3/0
1328G1 with Auxiliary 2/0
1382 with Auxiliary 1/0
1347 with Auxiliary #1
1383 with Auxiliary #2
1384 with Auxiliary #4
1348 with Auxiliary #6
53.5
42.4
33.6
21.2
13.3
53.5
42.4
33.6
21.2
13.3
85.0
67.4
53.5
42.4
33.6
21.2
13.3
85.0
67.4
53.5
42.4
33.6
21.2
13.3
Part Numbering Notes:
1) To order SPEC Pak
™
Shell Kits only (no internal Powerpole
®
housings or contacts), use part numbering on page 4 only.
Plug Shell Kit
Example: SK6-A95H02 or SK6-B95H02.
Powerpole
®
housings, contacts and wire protection may be ordered separately, see pages 6 thru 9 for
information.
2) To order customer configured SPEC Pak
™
connectors (including internal Powerpole
®
housings and contacts) use Part Number Plan across
the top of pages 4 and 5.
Customer Configured SPEC Pak
™
Plug Connector Example: SK6-A95H03PS04-A22.
3) To order a custom configuration which is not listed on page 7 thru 9, use APP custom part number configurator on the APP
®
website,
www.andersonpower.com or contact factory.
NOTE: 1. Custom configurations may not be UL Recognized.
2. Contact code designation #14 to 16, #25 to 29 and #87 to 93 use 4 each of part number PM1612S30 (Pins) & 4 each of part number PM16S12S32 (Sockets) as signal.
Out of Box is an unboxing example for CC3200 LaunchPad. Through HTTP Server, the client can control the LED light on the board, read the temperature sensor on the board, and detect the status of the a...
What factors are mainly related to leakage inductance? The impact of shielded winding on the operation of the transformer? Analysis of the switching process of the flyback power supply? Design of the ...
I participated in a group purchase on a forum before and bought a JlinkV8.
【Group purchase】J-link V-7 (finished products or PCB parts), V8 finished products are in progress......
https://bbs.eeworld.c...
1. Introduction
RFID (radio frequency identification) is a non-contact automatic identification technology that emerged in the 1990s. It uses the characteristics of radio frequency signal prop...[Details]
As a wireless broadband metropolitan area network standard, WiMAX technology has greater advantages than previous 3.5GHz MMDS products in terms of non-line-of-sight transmission and spectrum utiliz...[Details]
As LEDs continue to improve in almost every aspect of performance and cost, LED lighting is being used in an increasingly wide range of applications, among which LED street lights are a focus of in...[Details]
This paper designs a dot matrix LED text display screen that is easy to update, expandable, and low-cost. The way to reduce costs is
① Use the Bluetooth data transmission function of mobile ph...[Details]
When choosing a laptop battery, you should consider several factors, such as power, appearance, and quality.
Regarding power, we often see that a manufacturer uses values such as the number ...[Details]
Electronic systems are located at different points on the automotive power bus and therefore often need to operate under very stringent power requirements. These include load dump, cold crank, very lo...[Details]
Battery life is critical for portable applications. For applications such as smoke detectors, security devices, and thermostats, factory-installed batteries need to last for more than 10 years. The...[Details]
1 Introduction
Building Automation System (BAS) is a distributed monitoring system (DCS) designed according to distributed information and control theory. It is the result of the mutual de...[Details]
1 Introduction
With the development of control, computer, communication, network technology, etc., a new control technology, namely fieldbus, has emerged in the field of industrial control...[Details]
1. Introduction
Testing the temperature of steel billets before rolling is an important measure to ensure the quality of steel. Traditional manual testing is difficult to ensure product qu...[Details]
PV inverter manufacturer SMA has launched its first DC arc fault circuit interrupter (AFCI) PV inverter and has received UL certification.
The new SunnyBoy AFCI inverter models include 3000-US...[Details]
Capacitors
are basic components in various electronic devices and are widely used for bypassing, coupling,
filtering
, tuning, etc. in electronic circuits. However, to use capacitors,...[Details]
Spatial Division Multiplexing (SDM) MIMO processing can significantly improve spectrum efficiency and thus greatly increase the capacity of wireless communication systems. Spatial Division Multip...[Details]
D5026A is a driver IC designed by Shanghai Debei Electronics for energy-saving LED display screens. Its design concept is energy-saving and compatible with existing solutions, that is, it can be ...[Details]
LED light sources have many environmental advantages, but early products still have certain technical bottlenecks in heat dissipation and high brightness design that cannot be broken through....[Details]