EEWORLDEEWORLDEEWORLD

Part Number

Search

FN284-2-06

Description
Terminal Block Tools u0026 Accessories END BRACKET
CategoryThe connector    The connector   
File Size328KB,5 Pages
ManufacturerSchaffner
Environmental Compliance
Download Datasheet Parametric View All

FN284-2-06 Online Shopping

Suppliers Part Number Price MOQ In stock  
FN284-2-06 - - View Buy Now

FN284-2-06 Overview

Terminal Block Tools u0026 Accessories END BRACKET

FN284-2-06 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSchaffner
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Other featuresSTANDARDS: CSA, UL
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings2A, 250VAC
Installation typePANEL
Maximum operating temperature85 °C
Minimum operating temperature-25 °C
OptionsGENERAL PURPOSE
Termination typeSOLDER
Total number of contacts3
EMC/EMI Products > FN 280
IEC Inlet Filters
FN 280
Compact Filtered Power Entry Module
n
n
n
n
n
n
n
Rated currents up to 10A
Single or dual-fuse holder
Fuses Ø5 x 20mm
2-pole rocker switch
General purpose application
Optional earth line choke (E type)
Optional medical version (B type)
Approvals
Technical specifications
Maximum continuous operating voltage:
Operating frequency:
Rated currents:
High potential test voltage:
250VAC, 50/60Hz
50 to 400Hz
1 to 10A @ 40°C max.
P –> PE 2000VAC for 2 sec (standard types)
P –> PE 2500VAC for 2 sec (B types)
P –> N 760VAC for 2 sec
IP40 according to IEC 60529
-25°C to +85°C (25/85/21)
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
UL 94V-2 or better
1,500,000 hours
1 or 2 fuses (Ø5 x 20mm)
max. 250V ~ (text is print. below fuse symbol)
2-pole, dark not illuminated
Marking I - 0
Inrush current 82A
6,000 on-off operations according to UL 1054, TV 5
10,000 on-off operations according to ENEC
50,000 cycles
10A, 125VAC; 10A, 250VAC; 1/3HP
10A (4A), 250VAC*
Typical electrical schematic
Standard types
Cx
N
PE
P
Line
Load
R
2xL1
2xCy
N‘
PE
P‘
Protection category:
Temperature range (operation and storage):
Design corresponding to:
Flammability corresponding to:
MTBF @ 40°C/230V (Mil-HB-217F):
Fuse holder:
Marking:
Rocker switch description:
Function:
Electrical specifications:
E types
Cx
N
PE
P
Line
L2
Load
R
2xL1
2xCy
N‘
PE
P‘
Mechanical life:
Switch ratings:
USA (UL) and Canada (C-UL):
Europe (ENEC):
*
Value in () relates to the inductive current charge: cos
g
= 0.65
Features and benefits
The FN 280 power entry module combines
an IEC inlet, a mains filter with single or dual-
fuse holder and a 2-pole rocker switch in a
small form factor. Choosing FN 280 product
line brings you the rapid availability of a
standard filter associated with the necessary
safety acceptances. Standard IEC connector
filters are a practical solution helping you
to pass EMI system approval in a short time.
A wide selection on amperage ratings, fuse
options, mounting possibilities and filters for
medical applications are designed to offer
you the desired solution.
n
n
n
n
n
Typical applications
n
High conducted attenuation performance,
based on chokes with high saturation
resistance and excellent thermal behavior.
Rear/front or snap-in mounting.
Single or dual-fuse holder.
2-pole rocker switch.
Custom-specific versions are available on
request.
Portable electrical and electronic
equipment
n
n
n
Consumer goods
EDP and office equipment
Single-phase power supplies, switch-mode
power supplies
n
n
Test and measurement equipment
Medical equipment
[Shanghai Hangxin ACM32F070 development board + touch function evaluation board evaluation] + use of segment code LCD screen display
The ACM32F070 development board and the touch function evaluation board can better realize human-computer interaction. The segment code LCD screen on the function board can display 2 lines of 4-bit da...
jinglixixi Domestic Chip Exchange
Emergency help: The energized coil generates a magnetic field
This is a scanning gun. Can anyone explain how the coil generates a magnetic field after being energized, and the magnetic field drives the magnet on the pendulum mirror to swing? How can an alternati...
哎丹杰 Analog electronics
ds18b20 reading error rate problem
DS18B20 pulls up a 5.1K resistor, uses LPC2200's GPIO port to control DQ first, and uses 3.3V power supply (non-parasitic mode). AXD debugging, I counted the probability of possible errors, about 1%. ...
manman9258 Embedded System
Linear displacement measuring instrument
For a linear displacement measuring instrument, when the measured displacement changes from 4.5mm to 5.0mm, the output voltage of the displacement measuring instrument decreases from 3.5V to 2.5V. Cal...
297072811 Sensor
Received the MSP430 board...
The classic TI red and black, but there is no CD, which is a pity. According to the manual, all tools and documents must be downloaded from the TI website...http://processors.wiki.ti.com/index.php/MSP...
youki12345 Microcontroller MCU
How effective is the oscilloscope adjustment program?
[i=s]This post was last edited by hbdg on 2014-12-13 10:26[/i] Is a 20M analog oscilloscope okay?...
hbdg 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 9  494  1055  962  2113  1  10  22  20  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号