Precision modular connectors to suit your application
Since its creation in Switzerland in 1946 the LEMO Group has been recognized as a global leader of circular Push-Pull con-
nectors and connector solutions. Today LEMO and its affiliated companies, REDEL and COELVER, are active in more than
80 countries with the help of over 40 subsidiaries and distributors.
Over 75’000 connectors
The modular design of the LEMO range provides over 75’000 connectors from miniature ø 3 mm to ø 50 mm, capable of han-
dling cable diameters up to 30 mm and for up to 114 contacts.
This vast portfolio enables you to select the ideal connector configuration to suit almost any specific requirement in most mar-
kets, including medical devices, test and measurement instruments, machinery, audio video broadcast, telecommunications
and military.
LEMO’s Push-Pull Self-Latching Connection System
(not shown in this catalogue)
This self-latching system is renowned worldwide for its easy and quick mating and unmating features. It provides absolute secu-
rity against vibration, shock or pull on the cable, and facilitates operation in a very limited space.
The LEMO self-latching system allows the connector
to be mated by simply pushing the plug axially into the
socket.
Once firmly latched, connection cannot be broken by
pulling on the cable or any other component part other
than the outer release sleeve.
When required, the connector is disengaged by a sin-
gle axial pull on the outer release sleeve. This first dis-
engages the latches and then withdraws the plug from
the socket.
UL Recognition
LEMO connectors are recognized by the Underwriters Laboratories (UL). The approval of the complete system (LEMO
connector, cable and your equipment) will be easier because LEMO connectors are recognized.
CE marking
CE marking
means that the appliance or equipment bearing it complies with the protection requirements of one or
several European safety directives. CE marking
applies to complete products or equipment,
but not to electrome-
chanical components, such as connectors.
RoHS
LEMO connector specifications conforms the requirements of the RoHS directive (2011/65/EU) of the European Parliament
and the latest amendments. This directive specifies the restrictions of the use of hazardous substances in electrical and elec-
tronic equipment marketed in Europe.
www.lemo.com
®
®
V Series
V series connectors have been developed for utilisation where protection must be guaranteed under high pressures of
liquids. The basic elements, insulators, contacts and clamping system are from the S and E series. The push-pull latching
system has been replaced by a screw coupling system with watertightness maintained by compression of an O-ring in
FPM (Viton
®
) according to the triangular shaped cavity principle. There are multiple application possibilities, from nuclear physics
to the petroleum industry. After cable assembly the rear part must be covered with an adhesive heatshrink boot in order to
ensure watertightness on the cable side. V series connectors provide the following main features:
– unipole and multipole type
– coaxial, triaxial or mixed type available upon request
– polarisation by stepped insert (half moon)
– 360° screening for full EMC shielding
– rugged housing for extreme working conditions.
Interconnections
Models
(page 3)
Straight plugs
Fixed sockets
Free sockets
FVN
EVP
PVP
FVN
PSN
PVP
FVN
PSN
PVP
Part Section Showing Internal Components (multipole)
Straight plug
1
outer shell
3
1
outer shell
2
earthing crown
3
retaining ring
4
hexagonal nut
5
insulator
6
male contact
7
female contact
8
O-ring
2
4
1
8
5
7
6
9
8
7
6
2
3
5
1 10 12 13 11 4
2
coupling nut
3
circlip
4
collet nut
5
centre-piece
6
o-ring
7
insulator
8
male contact
9
female contact
10
earthing cone
11
collet
12
gasket
13
washer
Fixed socket
www.lemo.com
1
®
®
Part Number Example
Straight plug with cable collet
FVN
Model: (page 3)
Series: (page 3)
Insert configuration: (page 6)
Housing:
C = brass chrome-plated
S = stainless steel AISI 304 L
Insulator: L = PEEK
1)
T = PTFE
Variant: (page 12)
2)
Z = nut for fitting a bend relief
Cable ø: (page 11)
Collet type:
C = cable collet
K = oversize cable collet
Contact type:
A = male to solder
2V
306
C
L
A C 60
FVN.2V.306.CLAC60
= straight plug with cable collet, 2V series, multipole type with 6 contacts, outer shell in chrome-
plated brass, PEEK insulator, male solder contacts, C type collet for 6 mm diameter cable.
Free socket with cable collet
PVP
Model: (page 4)
Series: (page 4)
Insert configuration: (page 6)
Housing:
C = brass chrome-plated
S = stainless steel AISI 304 L
L = PEEK
Insulator: T = PTFE
1)
Variant: (page 12)
2)
Z = nut for fitting a bend relief
Cable ø: (page 11)
Collet type:
C = cable collet
K = oversize cable collet
Contact type:
L = female to solder
2V
306
C
L
C C 60
PVP.2V.306.CLLC60
= free socket with cable collet, 2V series, multipole type with 6 contacts, outer shell in chrome-
plated brass, PEEK insulator, female solder contacts, C type collet for 6 mm diameter cable.
Fixed socket
EVP
Model: (page 4)
Series: (page 4)
Insert configuration: (page 6)
Housing:
C = brass chrome-plated
S = stainless steel AISI 304 L
Contact type:
L = female to solder
Insulator: L = PEEK
1)
T = PTFE
3V
310
S
L
L
EVP.3V.310.SLL
= fixed socket, nut fixing, 3V series, multipole type with 10 contacts, outer shell in stainless steel, PEEK
insulator, female solder contacts.
Note:
1)
PTFE insulator for unipole type only.
2)
The «Variant» position in the reference is used to specify either the presence of a collet nut for fitting the bend relief.
For models with collet nut for fitting the bend relief, a «Z» should be indicated and a bend relief can be ordered separately. An order for a connector with
bend relief should thus include two part numbers.
2
www.lemo.com
®
®
Models
Technical Characteristics
Mechanical and Climatical
Characteristics
Endurance
Temperature range
Salt spray corrosion test
Protection index (mated)
Resistance to hydrostatic
pressure (mated)
Climatical category
Value
Standard
Electrical
Characteristics
Shielding
efficiency
at 10 MHz
at 1 GHz
Value
> 95 dB
> 80 dB
Standard
IEC 60169-1-3
IEC 60169-1-3
> 1000 cycles IEC 60512-5 test 9a
-20° C, +200° C
> 144h
IEC 60512-6 test 11f
> IP 68
IEC 60529
~ 30 bars
1)
20/200/21
IEC 60512-7 test 14d
IEC 60068-1
Note:
1)
in order to perform correctly and withstand the pressure, cable
assembly shall be made according to instruction we recommand. See
page 15.
FVN
Straight plug with cable collet
Reference
Model
~L
S3
S2
~M
S1
Dimensions (mm)
A
17.2
19.3
23.5
27.8
34.3
50.0
B
10
12
16
18
24
38
L
34
43
52.5
61
71
94
M
29
35
42
47
57
78
N
13.5
14.0
15.5
16.5
17.5
21.0
S1
16
18
22
26
32
47
S2
9
10
14
16
22
34
S3
8
9
12
15
19
30
Series
0V
1V
2V
3V
4V
5V
N
øB
øA
FVN
FVN
FVN
FVN
FVN
FVN
FVN
Straight plug with oversize cable collet
1)
Reference
~L
~M
S4
S3 S2
S1
N
Dimensions (mm)
A
19.3
23.5
27.8
34.3
B
L
M
47
55
66
91
N
14.0
15.5
16.5
17.5
S1
18
22
26
32
S2
10
14
16
22
S3
12
15
19
30
S4
12
15
19
32
Model
FVN
FVN
FVN
FVN
Series
1V
2V
3V
4V
øB
øA
14.5 55
17.0 65
22.0 80
36.0 105
Note:
1)
correspond to K type of collet, the fitting of oversize collets onto
this model allows them to be fitted to the cables that can be accommodated
by the next housing size up (see page 11).
FVN
Straight plug, cable collet
and nut for fitting a bend relief
1)
Reference
Model
~L
S3
S2
~M
S1
Dimensions (mm)
A
17.2
19.3
23.5
27.8
34.3
B
10
12
16
18
24
L
34
43
52
60
71
M
29
35
42
47
57
N
13.5
14.0
15.5
16.5
17.5
S1
16
18
22
26
32
S2
9
10
14
16
22
S3
7
9
12
15
19
Series
0V
1V
2V
3V
4V
N
øB
øA
FVN
FVN
FVN
FVN
FVN
Note:
1)
to order, add a «Z» at the end of the reference.
The bend relief must be ordered separately (see pages 141 and 142 of the
I recently went out for an interview and the other party gave me a form. On it, there was a line asking whether I would accept overtime, whether I would accept business trips, and another one I couldn...
[size=3]After the alternating current is rectified by the diode, the direction becomes single, but the size (current intensity) is still in a state of constant change. This kind of pulsating direct cu...
1) EDMA Overview ① There are two ways to initiate EDMA data transmission: ü CPU-initiated EDMA data transmission (asynchronous mode): When transmission is required, the CPU sets the corresponding bit ...
introduction
my country has a vast territory and a large population. The scale of housing construction is huge, and the amount of residential construction is large and wide. It is still on t...[Details]
This article discusses how to wake up a touch-sensitive device such as a tablet without touching the device, using basic gesture recognition and novel proximity sensors. The article discusses the p...[Details]
China's new energy vehicles are in a transition period from research and development to real industrial development. In 2012, with the intensive launch of new energy vehicle policy planning, the de...[Details]
Images in science fiction movies often break through the limits of reality, such as in the movie "Minority Report." Tom Cruise uses a multi-touch screen to browse information. Capacitive sensing te...[Details]
From the PIC16F946 datasheet, we know that there are two ways to write values to the LCD for display:
1. Directly write the value to LCDDATA1~LCDDATA23
2. Use disconnect t...[Details]
I. Introduction
Since RS232 has a short communication distance (only 15 meters according to EAT/TAI-232 standard), and can only perform point-to-point communication, it cannot directly f...[Details]
Xiaomi, a well-known Internet phone in mainland China, won a million-unit order contract from China Unicom on November 20 last year, which made Xiaomi famous in mainland China. In April this year...[Details]
Digital array radar (DAR) uses digital beam forming (DBF) in both receiving and transmitting modes to achieve flexible distribution and reception of RF signal power in the airspace, obtain excellent t...[Details]
TC9012F is a universal CMOS large-scale integrated circuit for infrared remote control signal transmission, suitable for remote control of TV, VTR, laser player and other equipment. In the market, ...[Details]
LED lighting: Basic circuit design can be completed in as little as one day
Semiconductor manufacturers are also getting involved in the LED lighting business. The power circuit of LED req...[Details]
1. Overview
At present, an information revolution is in the ascendant around the world, led by microelectronics, computers and communication technologies, and centered on information technolog...[Details]
1 Introduction
With the improvement of people's quality of life, lamps are no longer just basic indoor lighting tools, but also a kind of practical art for architectural decoration. When ther...[Details]
introduction
At present, measuring instruments are developing towards networking, and each individual embedded instrument will become a node on the Internet. This system realizes the network...[Details]
With the rapid development of wireless
digital communication
, more challenges have been raised for integrated circuit design and testing. In the product design stage, in order to ensure
t...[Details]
The launch of Shenzhou IX is imminent, and Tiangong is welcoming visitors again. Yesterday, Professor Fu Qiang, Vice President of the Institute of Science and Industrial Technology of Harbin Instit...[Details]