This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LFA10F-3R3-Y
6.6
3.3V 2A
LFA10F-5
10
5V 2A
LFA10F-12
10.8
12V 0.9A
LFA10F-15
10.5
15V 0.7A
LFA10F-24
12
24V 0.5A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
ACIN 100V
ACIN 200V
LFA10F-3R3-Y
LFA10F-5
LFA10F-12
LFA10F-15
LFA10F-24
*3
AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2)
0.18typ (Io=100%)
0.26typ (Io=100%)
0.11typ (Io=100%)
0.16typ (Io=100%)
50 / 60 (47 - 440)
68.0typ
74.0typ
76.5typ
77.5typ
79.5typ
68.5typ
76.0typ
79.0typ
80.0typ
83.0typ
15typ (Io=100%)
30typ (Io=100%)
0.15/0.30max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
2.0
2.0
0.9
0.7
0.5
20max
20max
48max
60max
96max
40max
40max
100max
120max
150max
80max
80max
120max
120max
120max
140max
140max
160max
160max
160max
190max
160max
240max
240max
280max
120max
120max
150max
150max
150max
160max
160max
180max
180max
180max
240max
240max
300max
300max
320max
50max
50max
120max
150max
240max
60max
60max
150max
180max
290max
20max
20max
48max
60max
96max
200typ (ACIN 100V, Io=100%)
*Start-up
time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100V, Io=100%)
2.85 to 3.63
Fixed (“Y”option is available for adjusting output voltage between
±10%)
3.30 to 3.40
4.90 to 5.30
11.50 to 12.50
14.40 to 15.60
23.00 to 25.00
Works over 105% of rating and recovers automatically
4.00 to 5.25
5.75 to 7.00
13.80 to 16.80
17.25 to 21.00
27.60 to 33.60
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000 feet) max
*3
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
Optional chassis and cover material : Electric galvanizing steel board.
¶
Dimensions in mm, [ ]=inches
¶
Mounting torque (Mounting hole of chassis) : 0.6N
-
m (6.3kgf
-
cm) max
1-1123722-5
1-1123722-2
¶
I/O Connector is Mfr. Tyco Electronics
¶
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5.
[0.63]
16
[1.26]
32
LFA-3
[2.36]
FG
CN1
5
CN2
1
2
Output(-)
Output(+)
[1.18]
Input(N)
[0.59]
50
15
FG
1
2
Output(-)
Output(+)
31.7
CN2
30
60
AC-DC Power Supplies Open Frame/ Enclosed Type
Ordering information
LFA15F
LF
1
2
A
3
15
4
F
5
-O
6
-O
R
Recommended EMI/EMC Filter
NAC-04-472
LFA
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
The EMI/EMC Filter is recommended
to connect with several devices.
1
Series name
2
Single output
3
Output wattage
4
Universal input
5
Output voltage
6
Optional
C : with Coating
G : Low leakage current
J1 : VH(J.S.T.)connector type
S : with Chassis
SN: with Chassis & cover
Y : with Potentiometer
Specification is changed at
option, refer to Instruction
Manual.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LFA15F-3R3-Y
9.9
3.3V 3A
LFA15F-5
15
5V 3A
LFA15F-12
15.6
12V 1.3A
LFA15F-15
15
15V 1A
LFA15F-24
16.8
24V 0.7A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
ACIN 100V
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
*5
LINE REGULATION[mV]
LOAD REGULATION[mV]
*5
0 to +50C
RIPPLE[mVp-p]
-10 - 0C
*1
Io=0 - 35%
0 to +50C
RIPPLE NOISE[mVp-p]
OUTPUT
-10 - 0C
*1
Io=0 - 35%
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
*2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
PROTECTION OVERVOLTAGE PROTECTION
CIRCUIT AND OPERATING INDICATION
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
ISOLATION
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
AGENCY APPROVALS
SAFETY AND
NOISE
CONDUCTED NOISE
REGULATIONS HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
EFFICIENCY[%]
*1
ACIN 100V
ACIN 200V
INPUT
LFA15F-3R3-Y
LFA15F-5
LFA15F-12
LFA15F-15
LFA15F-24
AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2)
*3
0.24typ (Io=100%)
0.35typ (Io=100%)
0.15typ (Io=100%)
0.20typ (Io=100%)
50 / 60 (47 - 440)
68.0typ
73.0typ
76.0typ
77.0typ
78.0typ
69.0typ
76.0typ
78.5typ
80.0typ
81.5typ
15typ (Io=100%) (At cold start) (Ta=25C)
30typ (Io=100%) (At cold start) (Ta=25C)
0.15/0.30max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
3.0
3.0
1.3
1.0
0.7
20max
20max
48max
60max
96max
40max
40max
100max
120max
150max
80max
80max
120max
120max
120max
140max
140max
160max
160max
160max
190max
160max
240max
240max
280max
120max
120max
150max
150max
150max
160max
160max
180max
180max
180max
240max
240max
300max
300max
320max
50max
50max
120max
150max
240max
60max
60max
150max
180max
290max
20max
20max
48max
60max
96max
200typ (ACIN 100V, Io=100%)
*Start-up
time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100V, Io=100%)
2.85 to 3.63
Fixed (“Y”option is available for adjusting output voltage between
±10%)
3.30 to 3.40
4.90 to 5.30
11.50 to 12.50
14.40 to 15.60
23.00 to 25.00
Works over 105% of rating and recovers automatically
4.00 to 5.25
5.75 to 7.00
13.80 to 16.80
17.25 to 21.00
27.60 to 33.60
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000 feet) max
*3
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
Optional chassis and cover material : Electric galvanizing steel board.
¶
Dimensions in mm, [ ]=inches
¶
Mounting torque (Mounting hole of chassis) : 0.6N
-
m (6.3kgf
-
cm) max
1-1123722-5
1-1123722-2
¶
I/O Connector is Mfr. Tyco Electronics
¶
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5.
16
PCB t=1.6
[0.63]
¶1
LFA-5
[1.26]
32
[2.36]
60
Voltage adjust
(LFA15F-3R3-Y or optional)
CN1
CN2
1
2
FG
5
Output(-)
Output(+)
[1.18]
50
30
1
2
[0.59]
CN1
CN2
Output(-)
Output(+)
[1.17]
29.7
15
AC-DC Power Supplies Open Frame/ Enclosed Type
Ordering information
LFA30F
LF
1
2
A
3
30
4
F
5
-O
6
-O
R
Recommended EMI/EMC Filter
NAC-04-472
LFA
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
The EMI/EMC Filter is recommended
to connect with several devices.
1
Series name
2
Single output
3
Output wattage
4
Universal input
5
Output voltage
6
Optional
C : with Coating
G : Low leakage current
J1 : VH(J.S.T.)connector type
S : with Chassis
SN: with Chassis & cover
Y : with Potentiometer
Specification is changed at
option, refer to Instruction
Manual.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LFA30F-3R3-Y
19.8
3.3V 6A
LFA30F-5
30.0
5V 6A
LFA30F-12
30.0
12V 2.5A
LFA30F-15
30.0
15V 2A
LFA30F-24
31.2
24V 1.3A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
ACIN 100V
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
*5
LOAD REGULATION[mV]
*5
0 to +50C
*1
RIPPLE[mVp-p]
-10 - 0C
*1
0 to +50C
*1
RIPPLE NOISE[mVp-p]
-10 - 0C
*1
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
*2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
ACIN 100V
ACIN 200V
LFA30F-3R3-Y
LFA30F-5
LFA30F-12
LFA30F-15
LFA30F-24
AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2)
*3
0.50typ (Io=100%)
0.65typ (Io=100%)
0.30typ (Io=100%)
0.35typ (Io=100%)
50 / 60 (47 - 440)
73typ
76typ
79typ
81typ
82typ
75typ
79typ
81typ
83typ
84typ
15typ (Io=100%)
(At cold start)
(Ta=25C)
30typ (Io=100%)
(At cold start)
(Ta=25C)
0.30 / 0.65max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
6.0
6.0
2.5
2.0
1.3
20max
20max
48max
60max
96max
40max
40max
100max
120max
150max
80max
80max
120max
120max
120max
140max
140max
160max
160max
160max
120max
120max
150max
150max
150max
160max
160max
180max
180max
180max
50max
50max
120max
150max
240max
60max
60max
150max
180max
290max
20max
20max
48max
60max
96max
150typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
2.85 to 3.63
Fixed (“Y”option is available for adjusting output voltage between
±10%)
3.30 to 3.40
4.90 to 5.30
11.50 to 12.50
14.40 to 15.60
23.00 to 25.00
Works over 105% of rating and recovers automatically
4.00 to 5.25
5.75 to 7.00
13.80 to 16.80
17.25 to 21.00
27.60 to 33.60
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max
*3
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
What is ultrasound? What are the characteristics of ultrasound? It is very useful. You may not know it yet. In fact, it has nothing to do with our topic, but I still want to share it with you!...
DirectIO: The SRIO DirectIO transfer class is similar to a memcopy transfer between two SRIO devices. One of the devices is the master that initiates the transfer. The second device is the slave that ...
[i=s]This post was last edited by Tianyahaijiaosr on 2016-12-17 12:53[/i] My PCB contains four main components: microcontroller, serial touch screen, ADC, and op amp, all of which are powered by the s...
A new week has begun. With the release of our uS v0.1, the next thing we are going to implement is the communication console component I planned. Here is a brief explanation. Console, this name imitat...
1. Several nouns
ABI:
The specifications that an executable file must follow in order to run in a specific execution environment;
Separately generated relocatabl...[Details]
PV DC fuses are safety devices used to protect PV panels, inverters, and DC loads. To ensure their safety and reliability, they must be UL248 certified.
Before applying for UL248 certifi...[Details]
Abstract:
With the increasing complexity of smart vehicle electrical and electronic architectures, the full lifecycle management of vehicle electronic control components faces multiple challe...[Details]
Most of the houses we live in now are elevator buildings, mainly because it is more convenient to go up and down the stairs! It can also make life more comfortable. It even helps to increase the ad...[Details]
Some time ago, I attended the 4th Energy Chemistry Forum of the Chinese Chemical Society and learned about high-energy-density and high-safety batteries. I would like to summarize and share this wi...[Details]
Electric vehicles are currently gaining momentum, but this is just a facade. Fuel-powered vehicles remain unchallenged. While electric vehicles boast unique advantages in environmental emissions an...[Details]
Whether it is an electric car or an ordinary fuel car, for the vast majority of car buyers, the final cost of use is what they care about most. For fuel cars, how to save fuel is what drivers care ...[Details]
Introduction to the principles of speech recognition technology
Automatic speech recognition (ASR) technology aims to enable computers to understand human speech and extract the textual inform...[Details]
With the rapid advancement of automation technology, collaboration between robots is no longer just science fiction. Imagine dozens of machines moving goods in a warehouse without interfering with ...[Details]
On August 21, WeRide officially launched WePilot AiDrive, a one-stage end-to-end assisted driving solution developed in cooperation with Bosch. This comes only half a year after the two parties' "t...[Details]
On August 22, according to the Ministry of Industry and Information Technology's official website, my country's first mandatory national standard for the control of hazardous substances in electric...[Details]
Tires are a very important component for cars. They are related to the driving experience of the vehicle. We are almost inseparable from cars in our daily lives. For tires, according to the role of...[Details]
The complexity of the integrated circuits (ICs) used in electronic systems in vehicles is increasing. They aim to execute artificial intelligence (AI) algorithms to control autonomous driving funct...[Details]
In daily life, power transformers have different functions and uses due to different usage scenarios. The most common ones can be divided into: control transformers, isolation transformers, rectifi...[Details]
To improve the lateral active safety of intelligent connected vehicles, the identification and definition of unexpected functional safety scenarios for the EPS (Electronic Steering System) ...[Details]