Off-line systems with auto-ranging or PFC front ends, industrial and process control,
distributed power, medical, ATE, communications, defense and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost-effectiveness of a
mature power component.
High-frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V300A12T500BL2
300A
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
=
–10 to +100
–20 to +125
C
=
–20 to +100
–40 to +125
T
=
–40 to +100
–40 to +125
H
=
–40 to +100
–55 to +125
M
=
–55 to +100
–65 to +125
B
Output Power
P
OUT
160W
264W, 200W
400W, 300W
400W, 300W
500W, 400W
500W, 400W
500W, 400W
500W, 400W
500W, 400W
500W, 400W
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
2
= 2V
3V3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48 =
48V
V
OUT
2V
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
Finish
Pin Style
Tin/Lead
Blank:
Short
Tin/Lead
L:
Long
Gold
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
300V Maxi Family
Page 1 of 14
Rev 10.2
12/2017
300V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
147.4
378.7
174.6
152.8
393.8
412.6
1.2
Min
180
Typ
300
Max
375
400
178.2
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
<100ms
Notes
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
2V
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
–0.5 to 3.1
–0.5 to 4.7
–0.5 to 7.0
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 47.4
–0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 9.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20263)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.08
0.07
4.9
1.1
165
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
300V Maxi Family
Page 2 of 14
Rev 10.2
12/2017
300V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4
mA. See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
6.5
[184.3]
7.4
[209.3]
100
3000
1500
500
10
7.3
[207.5]
8.2
[232.5]
115
cURus, cTÜVus, CE
8.1
[230.7]
9.0
[255.7]
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
[grams]
ounces
[grams]
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
300V Maxi Family
Page 3 of 14
Rev 10.2
12/2017
300V Input
MODULE-SPECIFIC OPERATING SPECIFICATIONS
2V
OUT
, 160W (e.g. S300A2C160BL, V300A2C160BL)
Parameter
Efficiency
S300A2C160BL (enhanced efficiency)
V300A2C160BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
74.5
72.5
2.7
Typ
82.5
74
262
2.8
7.9
±0.02
92
92
Max
Unit
%
327
2.9
8.1
±0.2
80
112
112
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
3.3V
OUT
, 264W (e.g. S300A3V3C264BL, V300A3V3C264BL)
Parameter
Efficiency
S300A3V3C264BL (enhanced efficiency)
V300A3V3C264BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
81.0
80.0
4.14
Typ
84.5
81.2
288
4.3
8.1
±0.02
92
92
Max
Unit
%
360
4.46
9.4
±0.2
80
112
112
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
3.3V
OUT
, 200W (e.g. S300A3V3C200BL, V300A3V3C200BL)
Parameter
Efficiency
S300A3V3C200BL (enhanced efficiency)
V300A3V3C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
80.5
78.1
4.14
Typ
84.5
79.6
80
4.3
6.2
±0.02
69.7
69.7
Max
Unit
%
100
4.46
12
±0.2
60.6
81.9
81.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.8
42.4
5V
OUT
, 400W (e.g. S300A5C400BL, V300A5C400BL)
Parameter
Efficiency
S300A5C400BL (enhanced efficiency)
V300A5C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.8
81.5
6.03
Typ
86.5
83
316
6.25
6.2
±0.02
92
92
Max
Unit
%
395
6.47
9.3
±0.2
80
112
112
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
300V Maxi Family
Page 4 of 14
Rev 10.2
12/2017
300V Input
MODULE-SPECIFIC OPERATING SPECIFICATIONS (CONT.)
5V
OUT
, 300W (e.g. S300A5C300BL, V300A5C300BL)
Parameter
Efficiency
S300A5C300BL (enhanced efficiency)
V300A5C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.5
83.2
6.03
Typ
86.5
84.2
150
6.25
12.0
±0.02
69
69
Max
Unit
%
188
6.47
13.2
±0.2
60
81
81
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.2
42
8V
OUT
, 400W (e.g. S300A8C400BL, V300A8C400BL)
Parameter
Efficiency
S300A8C400BL (enhanced efficiency)
V300A8C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.7
82.5
9.36
Typ
87.0
83.8
320
9.7
14.6
±0.02
57.5
57.5
Max
Unit
%
400
10.1
16
±0.2
50
67.5
67.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
51
35
8V
OUT
, 300W (e.g. S300A8C300BL, V300A8C300BL)
Parameter
Efficiency
S300A8C300BL (enhanced efficiency)
V300A8C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
85.0
82
9.36
Typ
87.0
84.8
250
9.7
8.9
±0.02
43.1
43.1
Max
Unit
%
313
10.1
10
±0.2
37.5
50.7
50.7
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
38.2
26.2
12V
OUT
, 500W (e.g. S300A12C500BL, V300A12C500BL)
Parameter
Efficiency
S300A12C500BL (enhanced efficiency)
V300A12C500BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.6
85.5
13.7
Typ
88.0
86.7
280
14.3
12.2
±0.02
48
48
Max
Unit
%
350
14.9
13.2
±0.2
41.6
60.5
60.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
I am working on a photovoltaic inverter power supply, but the hardware has not been completed. The H-bridge used in the DC-AC circuit can output a sine wave, but the LC filter part has not been done w...
PBP is a brand of Shenzhen Santak Power Supply Co., Ltd., specializing in the production and research and development of uninterruptible power supplies. The company currently produces solar inverter ,...
[i=s]This post was last edited by yl20084784 on 2016-6-29 14:56[/i] I made a board with STM32F107+DP83848 connected to Ethernet, PCB, double layer. The last time I made the board, the program was norm...
[i=s]This post was last edited by tiankai001 on 2015-7-23 22:29[/i] [align=center][size=5]How to read circuit diagrams: Recommended resources 2. [/size][color=rgb(0, 0, 0)][backcolor=rgb(237, 235, 235...
No matter which processor you are learning, the first thing you need to understand is the registers and working mode of the processor.
ARM has 37 registers, including 31 general registers and ...[Details]
1 Introduction
PROFIBUS is an international, open, and manufacturer-independent fieldbus standard. It is widely used in manufacturing automation, process industry automation, and automatio...[Details]
With the rapid development of intelligent control technology, computers and information technology, the trend of information appliances IA (Information Application), computers and communications integ...[Details]
introduction
At present, measuring instruments are developing towards networking, and each individual embedded instrument will become a node on the Internet. This system realizes the network...[Details]
0 Introduction
Under normal circumstances, the three-phase power in the power system is symmetrical, and they meet certain amplitude and phase conditions; but when the load changes, the syst...[Details]
Traditional
virtual instruments
consist of a data acquisition
board
based on PCI bus and
corresponding software. However, with
the rapid development of
computer
network techno...[Details]
0 Introduction
In the design and construction of communication systems,
communication power supply
is called the heart of the communication system. The power supply system will dire...[Details]
For a long time, my country has implemented "community-style collective heating" for hot water heating, and settled accounts based on the heating area, regardless of whether the user uses heat. Thi...[Details]
New Automobile
Hydraulic Clutch
The hydraulic control system uses almost 100% advanced engineering plastics, which overcomes the shortcomings of the main and branch cylinders of metal clutc...[Details]
An intelligent vehicle is a robot that can automatically drive in an environment according to a pre-set mode, or it can autonomously perform specific operations according to the on-site situation. ...[Details]
0 Introduction
This paper designs a dot matrix LED text display screen that is easy to update, expandable, and low-cost. The ways to reduce costs are: ① Use the Bluetooth data transmission...[Details]
1. Electromagnetic compatibility design
Electromagnetic compatibility refers to the ability of electronic equipment to work in a coordinated and effective manner in various electromagnetic env...[Details]
Modern communication equipment, portable electronic products, laptops, electric vehicles, small satellites, etc. generally use batteries as power sources and are widely used. However, the batteries...[Details]
1. Sensor
According to the national standard GB7665-87, a sensor is defined as a device that can sense the specified measured quantity and convert it into a usable output signal according to a...[Details]
0 Introduction
In the fields of petroleum, chemical industry, metallurgy, electricity, textile, light industry, water conservancy and other industries and scientific research, relevant pressur...[Details]