EEWORLDEEWORLDEEWORLD

Part Number

Search

SUTW31215

Description
Isolated DC/DC Converters 3W 15V/30V 0.1A Through Hole
CategoryPower/power management    The power supply circuit   
File Size336KB,7 Pages
ManufacturerCosel
Environmental Compliance
Download Datasheet Parametric View All

SUTW31215 Online Shopping

Suppliers Part Number Price MOQ In stock  
SUTW31215 - - View Buy Now

SUTW31215 Overview

Isolated DC/DC Converters 3W 15V/30V 0.1A Through Hole

SUTW31215 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerCosel
package instruction,
Reach Compliance Codeunknown
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
DC-DC Converters PCB Mount Type
Ordering information
SUTW3
SUT
W
3
12
12
-O
R
1Series
name
2Dual
output
3Output
wattage
4Input
voltage
5Output
voltage
6Optional
G :Capacitor between Input
and Output is removed.
SU.SUC/SUT
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
SUTW30512
3.12
VOLTAGE[V]
*
1
t
12 or +24
CURRENT[A] 0.13
SUTW30515
3
t
15 or +30
0.1
SUTW31212
3.12
t
12 or +24
0.13
SUTW31215
3
t
15 or +30
0.1
SUTW32412
3.12
t
12 or +24
0.13
SUTW32415
3
t
15 or +30
0.1
SUTW34812
3.12
t
12 or +24
0.13
SUTW34815
3
t
15 or +30
0.1
SPECIFICATIONS
INPUT
MODEL
VOLTAGE[V]
*
2
CURRENT[A]
*
2
EFFICIENCY[%]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
-20 to +55
C
*
3
RIPPLE[mVp-p]
-40 to -20
C
*
3
-20 to +55
C
*
3
RIPPLE NOISE[mVp-p]
-40 to -20
C
*
3
-20 to +55
C
TEMPERATURE REGULATION[mV]
-40 to +55
C
*
4
DRIFT[mV]
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE
OUTPUT VOLTAGE SETTING[V] (t5%)
OVERCURRENT PROTECTION
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-CASE
OUTPUT-CASE
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CASE SIZE/WEIGHT
COOLING METHOD
SUTW30512
DC4.5 - 9
0.844typ
74typ
t
12(+24)
SUTW30515 SUTW31212
DC9 - 18
0.811typ
0.343typ
74typ
76typ
t
15(+30)
t
12(+24)
SUTW31215 SUTW32412
DC18 - 36
0.329typ
0.172typ
76typ
76typ
t
15(+30)
t
12(+24)
0.1
75max
750max
120max
150max
150max
200max
180max
290max
60max
0.13
60max
600max
120max
150max
150max
200max
150max
240max
50max
SUTW32415 SUTW34812
DC36 - 76
0.165typ
0.086typ
76typ
76typ
t
15(+30)
t
12(+24)
0.1
75max
750max
120max
150max
150max
200max
180max
290max
60max
0.13
60max
600max
120max
150max
150max
200max
150max
240max
50max
SUTW34815
0.083typ
76typ
t
15(+30)
0.1
75max
750max
120max
150max
150max
200max
180max
290max
60max
SU.SUC/SUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
by external VR
11.40 - 12.60 14.25 - 15.75 11.40 - 12.60 14.25 - 15.75 11.40 - 12.60 14.25 - 15.75 11.40 - 12.60 14.25 - 15.75
Works over 105% of rating and recovers automatically
Provided (Negative logic L : ON, H : OFF)
AC500V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (20
t
15
C
)
AC500V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (20
t
15
C
)
AC500V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (20
t
15
C
)
-40 to +85
C
, 20 - 95%RH (Non condensing) (Required Derating), 3,000m (10,000feet) max
-40 to +100
C
, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 98.0m/s
2
(10G), 3minutes period, 60minutes each along X, Y and Z axis
490.3m/s
2
(50G), 11ms, once each along X, Y and Z axis
UL60950-1, C-UL, EN60950-1
30.0
X
23.4
X
9.15mm [1.18
X
0.92
X
0.36 inches] (W
X
H
X
D) / 8g max
Convection/Forced air
0.13
0.1
0.13
60max
75max
60max
600max
750max
600max
120max
120max
120max
150max
150max
150max
150max
150max
150max
200max
200max
200max
150max
180max
150max
240max
290max
240max
50max
60max
50max
20max (Minimum input, Io=100%)
Fixed (TRM pin open)
t
5% adjustable
SAFETY
OTHERS
*1
*2
*3
*4
*
Output pins can be connected in series to make a 24V/30V output.
Rated input 5V, 12V, 24V or 48V DC Io=100%
Ripple and Ripple Noise is measured by using measuring board with capacitor with in 25mm from output pin terminals.
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
Parallel operation with other model is not possible.
SU
.SUC/SUT-40
SUC/SUT-40

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1756  1953  52  1765  2748  36  40  2  56  24 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号