EEWORLDEEWORLDEEWORLD

Part Number

Search

ZWS100AF5-J

Description
Switching Power Supplies 100W 5V 20A
CategoryPower/power management   
File Size535KB,2 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Download Datasheet Parametric View All

ZWS100AF5-J Online Shopping

Suppliers Part Number Price MOQ In stock  
ZWS100AF5-J - - View Buy Now

ZWS100AF5-J Overview

Switching Power Supplies 100W 5V 20A

ZWS100AF5-J Parametric

Parameter NameAttribute value
Product CategorySwitching Power Supplies
ManufacturerTDK Corporation
RoHSDetailsxwxbqcwaueydzsdyr
ProductSwitching Supplies
Output Voltage-Channel 15 VDC
Number of Outputs1 Output
Output Power100 W
Open Frame/EnclosedOpen Frame
Input Voltage85 VAC to 265 VAC
Output Current-Channel 120 A
IndustryCommercial
Length1.29 in
Width0.33 in
Height1.29 in
ApprovalsEN60950-1, UL60950-1
Factory Pack Quantity1
ZWS-AF Series
50W to 150W Single Output Low Cost, Worldwide Use
Features
u
Universal Input (85 - 265VAC)
u
Power factor Corrected
u
Input transient protected
u
2 year warranty
u
High quality design
u
Peak Power capability
Key Market Segments & Applications
Specifications
Model
AC Input Voltage range
DC Input Voltage range
Input Current (Typ) (1)
Inrush Current
Power Factor (1)
Maximum Ripple and Noise
Temperature Coefficient
Overcurrent Protection (4)
Hold Up Time (Typ) (1)
Leakage Current
Remote On / Off
Operating Temperature
Storage Temperature
Humidity (non condensing)
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (W x H x D)
Warranty
VAC
VDC
A
A
-
mV
-
-
ms
-
-
-
-
-
-
-
-
-
-
-
-
g
mm
yrs
ZWS75AF
ZWS100AF
ZWS150AF
85-265VAC (47-63Hz)
120-370VDC
0.8/0.4
1.2/0.6
1.4/0.7
2.0/1.0
14/28 25°C Ambient, Cold Start
Meets EN61000-3-2 (0.99/0.95)
3.3 & 5V: 120mV; 12 to 24V: 150mV; 36 & 48V: 200mV
<0.02%/°C
>105% of Peak Current Capability
20ms
0.5mA max 0.1mA (Typ) at 100VAC 0.16mA (Typ) at 230VAC
See installation manual (Not available with /A cover option)
Convection cooling - See table on page 2
0.7m/s air -10°C to +70°C, derate linearly to 70% load from 60°C to 70°C (2)
-30° to +85°C
Operating: 30 - 90% RH, storage 10-95% RH
I/P~Grnd 2kVAC (20mA), I/P~O/P 3kVAC (20mA), O/P~Grnd 500VAC (100mA) for 1 min.
>100M at 25C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark
designed to meet EN55011, EN55022-B, FCC Class B, VCCI-B
designed to meet EN61000-4-2,-3,-4,-5,-6,-8,-11
210
290
380
500
55 x 26 x 195
55 x 32 x 222
62 x 35 x 222
75 x 40 x 222
Two Years
ZWS50AF
Notes:
(1) 100/200VAC
(2) ZWS150AF -10 to 60°C, derate linearly to 70% load from 50°C to 60°C
(3) The peak current draw must not exceed a 10 second duration with a duty cycle of 35%
(4) Constant current limit with automatic recovery. Do not operate in a over-load or shorted output condition for more than 30 seconds.
(5) An overvoltage condition on the output will shut down the power supply. The power supply must be re-set by cycling the AC input.
For New Designs, See ZWSBAF Series
1-800-526-2324 • www.us.tdk-lambda.com/lp/
1
Disclaimer: us.tdk-lambda.com/lp/legal.htm
The program of 2812 is used in 28335 and an error occurs
We used 2812 before. Now we put the modified program into 28335 and found that we can't enter the timer interrupt at all.[This post was last edited by Siyuanhupan on 2009-3-5 07:39 PM]...
sanny777 Microcontroller MCU
About the problem of ucosII running
After creating the task, execute OSStart(), call OSStartHighRdy() in OSStart(), but OSStartHighRdy() function is not executed and jumps directly to the end of main function. What is the reason? Thank ...
liurong82 Real-time operating system RTOS
Raspberry Pi 3 beginner's guide - by RCSN
[url=home.php?mod=space&uid=530197]@RCSN[/url] [url=https://bbs.eeworld.com.cn/thread-507037-1-1.html][size=3] Notes for beginners learning Raspberry Pi 3 (1) - Three ways to obtain Raspberry Pi CPU i...
okhxyyo Linux and Android
Literacy Post--Professional Terms Network Engineers Must Know
Router question: 1. When to use multiple routing protocols? When two different routing protocols need to exchange routing information, multiple routing protocols are used. Of course, routing redistrib...
songbo RF/Wirelessly
(Ended) Free application evaluation: Have fun with STM32F769I with your friends
[align=left][url=https://bbs.eeworld.com.cn/thread-507646-1-1.html][size=6]>>Click to enter the award post[/size][/url][/align][align=left][b][font=微软雅黑][size=14pt][color=#000080] [/color][/size][/fon...
EEWORLD社区 stm32/stm8
LED driver safety knowledge is always in a hazy state:
The knowledge of LED driver safety regulations is always in a hazy state: some time ago, I was still asking about the knowledge of surge protection; whether a varistor must be added to the front end o...
czf0408 LED Zone

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2588  375  1188  2466  2843  53  8  24  50  58 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号