EEWORLDEEWORLDEEWORLD

Part Number

Search

GPC80C

Description
Switching Power Supplies 80W +5/+12/-15/+15V
CategoryPower/power management   
File Size281KB,2 Pages
ManufacturerSL Power
Download Datasheet Parametric Compare View All

GPC80C Online Shopping

Suppliers Part Number Price MOQ In stock  
GPC80C - - View Buy Now

GPC80C Overview

Switching Power Supplies 80W +5/+12/-15/+15V

GPC80C Parametric

Parameter NameAttribute value
Product CategorySwitching Power Supplies
ManufacturerSL Power
RoHSNo
ProductSwitching Supplies
Output Voltage-Channel 15 VDC
Output Voltage-Channel 212 VDC
Number of Outputs4 Output
Output Power80 W
Open Frame/EnclosedOpen Frame
Input Voltage85 VAC to 264 VAC
Output Current-Channel 112 A
Output Current-Channel 23 A
IndustryCommercial
Mounting StyleChassis
Length7 in
Width4.25 in
Height1.86 in
ApprovalsEN60950-1
Efficiency70 %
Cooling MethodConvection, Air-Cooled
Input Voltage, Max264 VAC
Input Voltage, Min85 VAC
Load RegulationRegulated
Mechanical StyleOpen / Enclosed Frame
Operating Temperature Range0 C to + 50 C
Output Current-Channel 31 A
Output Current-Channel 41 A
Output Voltage V1, Nominal5 VDC
Output Voltage V2, Nominal12 VDC
Output Voltage V3, Nominal- 15 VDC
Output Voltage V4, Nominal15 VDC
Output Voltage-Channel 3- 15 VDC
Factory Pack Quantityaceteqaz10
Unit Weight1.800 lbs
80 Watt Global Single and Multiple Output Performance Switchers
PERFORMANCE MEDICAL SWITCHERS
FEATURES:
• Wide-range ac input 85-264 Vac
• 2-year warranty
• Conducted EMI exceeds FCC Class B and CISPR 22
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
• Commercial Approved to UL1950, IEC950, EN60950 and
CSA22.2-234 L3
• Medical Approved to UL2601-1, IEC601-1 and CSA22.2
No. 601.1
• Complies with EN61000-3-2 Class A
• RoHS Compliant Model Available (G suffix)
SPECIFICATIONS
Ac Input
85-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated output load: 2.3 A
Hold-Up Time
20 ms minimum from loss of ac input at full load, nominal line (115 Vac).
Output Power
80 W continuous, 110 W with air flow. Peak ratings are for 60 s maximum
duration, 10% duty cycle. During peak load condition, output regulation may
exceed total regulation limits.
Overload Protection
Fully protected against short circuit and output overload. Short circuit protec-
tion is cycling type power limit on outputs 1 & 2; foldback type on outputs 3
& 4. Recovery after fault is automatic. Factory set to begin power limiting at
120 W. See output ratings chart for additional notes or conditions.
Overvoltage Protection
Main outputs: 124% ± 12% typical.
Efficiency
70% at full rated load, nominal input voltage, depending on model and load
distribution.
Input Protection
Internal ac fuse provided. Designed to blow only if a catastrophic failure oc-
curs in the unit.
Inrush Current
Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start
conditions will not exceed 34 A.
Temperature Coefficient
0.03%/°C typical on all outputs.
Environmental
Designed for 0 to 50°C operation at full rated output power; derate output
current and total output power by 2.5% per °C above 50°C. See Environmen-
tal and Packaging Specifications on next page.
Power Fail (optional)
TTL- or CMOS-compatible output goes low (< 0.5 V) 5 ms before output
voltage drops more than 4% below nominal voltage upon loss of ac power.
The signal is factory set to trip on 84 to 94 Vac brown-out depending upon
incoming line impedance and distortion. Other settings are available to the
user through adjustment of built-in potentiometer (consult factory for as-
sistance). For Power fail option, add -PF after model number.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise
probe directly across output terminals of the power supply.
Transient Response
Main output—500 μs typical response time for return to within 0.5% of final value
for a 50% load step change. ∆i/∆t<0.2 A/μs. Maximum voltage deviation is 3.5%.
Startup/shutdown overshoot less than 3%.
Remote Sense
Provided as a standard feature on single-output models.
Voltage Adjustment
Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following emissions
requirements:
EMI SPECIFICATIONS
Conducted Emissions GPC80
Conducted Emissions GPM80
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Line Frequency Harmonics
Commercial Leakage Current
0.7 mA 254 Vac @ 60 Hz input.
Commercial Safety
Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950. UL file
#E135803 commercial; CSA #LR46516 all. The output(s) are intended for safety
earthed Signal Output and Intermediate Circuits only. All dc outputs are SELV
under normal and single fault conditions.
Medical Leakage Current
35 μA 254 Vac @ 60 Hz input.
Medical Commercial Safety
Approved to UL2601-1, CSA-C22.2 No. 601.1 Level 3 and IEC601.1. UL file E116994;
CSA #LR46516. The output(s) are intended for safety earthed Signal Output and
Intermediate Circuits only. The output(s) are not acceptable for patient connection
without additional isolation. All dc outputs are SELV under normal and
single fault conditions.
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN55011Class B; FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
EN61000-3-2 Class A
GPC80 Commercial/GPM80 Medical
All specifications are typical at nominal input, full load at 25
O
C unless otherwise stated

GPC80C Related Products

GPC80C GPC80-28G GPC80P GPC80-15G GPM80-12G GPM80-24G GPM80A
Description Switching Power Supplies 80W +5/+12/-15/+15V Switching Power Supplies 80W 28V @ 2.9A Switching Power Supplies 80W +5/+24/-12/+12V Switching Power Supplies 80W 15V @ 5.3A Switching Power Supplies 80W 12V @ 6.7A Switching Power Supplies 80W 24V @ 3.4A Switching Power Supplies 80W +5/+12/-12/+12V
Product Category Switching Power Supplies Switching Power Supplies Switching Power Supplies Switching Power Supplies - Switching Power Supplies Switching Power Supplies
Manufacturer SL Power SL Power SL Power SL Power - SL Power SL Power
RoHS No Details No Details - Details No
Product Switching Supplies Switching Supplies Switching Supplies Switching Supplies - Switching Supplies Switching Supplies
Output Voltage-Channel 1 5 VDC 28 VDC 5 VDC 15 VDC - 24 VDC 5 VDC
Number of Outputs 4 Output 1 Output 4 Output 1 Output - 1 Output 4 Output
Output Power 80 W 81 W 80 W 80 W - 82 W 80 W
Open Frame/Enclosed Open Frame Open Frame Open Frame Open Frame - Open Frame Open Frame
Input Voltage 85 VAC to 264 VAC 85 VAC to 264 VAC 85 VAC to 264 VAC 85 VAC to 264 VAC - 85 VAC to 264 VAC 85 VAC to 264 VAC
Output Current-Channel 1 12 A 2.9 A 12 A 5.3 A - 3.4 A 12 A
Industry Commercial Commercial Commercial Commercial - Medical Medical
Mounting Style Chassis Chassis Chassis Chassis - Chassis Chassis
Length 7 in 7 in 7 in 7 in - - 7 in
Width 4.25 in 4.25 in 4.25 in 4.25 in - - 4.25 in
Height 1.86 in 1.68 in 1.86 in 1.68 in - - 1.86 in
Approvals EN60950-1 EN60950-1 EN60950-1 EN60950-1 - IEC601-1, UL2601-1 IEC601-1, UL2601-1
Load Regulation Regulated Regulated Regulated Regulated - Regulated Regulated
Unit Weight 1.800 lbs 1.800 lbs 1.800 lbs - - 1.800 lbs 1.800 lbs
Factory Pack Quantity - 60 10 60 - 40 10
I would like to ask a few questions about router embedding
What operating systems do Cisco, Huawei, Juniper, and Alcatel use? Do they have backend architectures, such as VxWorks? Which routers use Linux, Unix, UCLinux, VxWorks, or PSOS as their operating syst...
seven_zs Embedded System
Some updates from TI in early 2017
1. CCS V7 is out, supports c2000. I have tried it. 2. ControlSuite 3.4.4 is released, but I didn't see what's updated in the update log. 3. MotorWare 1_01_00_17 is released, and it can finally support...
watershade Microcontroller MCU
What to do if the Quartus II driver is incompatible with the laptop blue screen?
I bought a new Lenovo laptop, installed Quartus II 17.1, and when I plugged in the USB blaster, the laptop had a blue screen and said it was incompatible. The cable was fine, and I used an old compute...
郭家豪 FPGA/CPLD
Use VB2005 to simulate keystrokes in CE5.0
When using VB2005 to simulate keystrokes under CE5.0: keybd_event, sendinput, sendkeys and other functions cannot RegisterHotKey. It is not used successfully. Please help!...
辛蒂 Embedded System
A question about UCOS
I am a beginner in embedded systems and I have a few questions about task scheduling in uCOS that need to be answered urgently. (1) Is the currently running task still in the ready list: 1. Assuming i...
860122 Real-time operating system RTOS
Instrumentation Amplifiers—Avoid Common Design Pitfalls
[i=s]This post was last edited by dontium on 2015-1-23 11:45[/i] [align=left]An instrumentation amplifier (IA) is a combination of an operational amplifier and feedback resistors used to accurately ac...
德州仪器 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2685  2536  652  661  1271  55  52  14  26  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号