Railway/Transportation system applications including communications systems,
information display, lighting, control systems, ticket machines, passenger
entertainment, public address systems, door control, industrial power systems and power
generation systems.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Parameter
+IN to –IN voltage
PC to –IN voltage
PR to –IN voltage
SC to –OUT voltage
–Sense to –OUT voltage
Isolation voltage
IN to OUT
IN to base
OUT to base
Operating Temperature
Storage Temperature
Pin soldering temperature
Mounting torque
Rating
–0.5 to +260
–0.5 to +7.0
–0.5 to +7.0
–0.5 to +1.5
1.0
3000
1500
500
–55 to +100
–65 to +125
500 (260)
750 (390)
5 (0.57)
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
V
RMS
V
RMS
V
RMS
°C
°C
°F (°C)
°F (°C)
in-lbs (N-m)
Test voltage
Test voltage
Test voltage
M-Grade
M-Grade
<5 sec; wave solder
<7 sec; hand solder
6 each
Notes
Product Overview
These DC-DC converter modules use
advanced power processing, control and
packaging technologies to provide the
performance, flexibility, reliability and cost
effectiveness of a mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V110A24C400BL
V110A
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
= - 10 to +100 - 20 to +125
C
= - 20 to +100 - 40 to +125
T
= - 40 to +100 - 40 to +125
H
= - 40 to +100 - 55 to +125
M
= - 55 to +100 - 65 to +125
B
Output Power
V
OUT
P
OUT
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
150W, 200W
200W, 300W
200W, 300W
300W, 400W
300W, 400W
300W, 400W
300W, 400W
300W, 400W
300W, 400W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
3V3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
110V Maxi Family
Page 1 of 14
Rev 3.2
06/2017
vicorpower.com
800 927.9474
110V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
54
155.5
64
56
161.7
169.4
1.3
Min
66
Typ
110
Max
154
250
65.4
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
Notes
Per EN50155 and GBT-25119
<100ms
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
–0.5 to 4.7
–0.5 to 7.0
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 47.4
–0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 9.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20263)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.08
0.07
4.9
1.1
165
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
110V Maxi Family
Page 2 of 14
Rev 3.2
06/2017
vicorpower.com
800 927.9474
110V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
6.5
(184.3)
7.4
(209.3)
100
3000
1500
500
10
7.3
(207.5)
8.2
(232.5)
115
cURus, cTÜVus, CE
8.1
(230.7)
9.0
(255.7)
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
110V Maxi Family
Page 3 of 14
Rev 3.2
06/2017
vicorpower.com
800 927.9474
110V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3
V
OUT
, 200W (e.g. S110A3V3C200BL, V110A3V3C200BL)
Parameter
Efficiency
S110A3V3C200BL (enhanced efficiency)
V110A3V3C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.3
81.0
4.14
Typ
86.5
82.0
90
4.3
6.1
±0.02
69.7
69.7
Max
Unit
%
113
4.46
8.2
±0.2
60.6
81.9
81.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.8
42.4
3.3
V
OUT
, 150W (e.g. S110A3V3C150BL, V110A3V3C150BL)
Parameter
Efficiency
S110A3V3C150BL (enhanced efficiency)
V110A3V3C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.0
80.5
4.14
Typ
86.0
81.8
85
4.3
6.1
±0.02
52.3
52.3
Max
Unit
%
107
4.46
7
±0.2
45.45
61.5
61.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
46.4
31.8
5
V
OUT
, 300W (e.g. S110A5C300BL, V110A5C300BL)
Parameter
Efficiency
S110A5C300BL (enhanced efficiency)
V110A5C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.2
83.0
6.03
Typ
88.1
84.9
80
6.25
12.1
±0.02
69
69
Max
Unit
%
100
6.47
13.1
±0.2
60
81
81
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.2
42
5
V
OUT
, 200W (e.g. S110A5C200BL, V110A5C200BL)
Parameter
Efficiency
S110A5C200BL (enhanced efficiency)
V110A5C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.3
84.5
6.03
Typ
88.5
85.5
166
6.25
8.3
±0.02
46
46
Max
Unit
%
208
6.47
9.7
±0.2
40
54
54
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
40.8
28
110V Maxi Family
Page 4 of 14
Rev 3.2
06/2017
vicorpower.com
800 927.9474
110V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
8
V
OUT
, 300W (e.g. S110A8C300BL, V110A8C300BL)
Parameter
Efficiency
S110A8C300BL (enhanced efficiency)
V110A8C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.5
84.5
9.36
Typ
88.5
86.5
215
9.7
9
±0.02
43.1
43.1
Max
Unit
%
269
10.1
10
±0.2
37.5
50.7
50.7
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
38.2
26.2
8
V
OUT
, 200W (e.g. S110A8C200BL, V110A8C200BL)
Parameter
Efficiency
S110A8C200BL (enhanced efficiency)
V110A8C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
87.7
86.8
9.36
Typ
89.0
87.7
220
9.7
5.4
±0.02
28.8
28.8
Max
Unit
%
275
10.1
6.4
±0.2
25
33.8
33.8
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
25.5
6
12
V
OUT
, 400W (e.g. S110A12C400BL, V110A12C400BL)
Parameter
Efficiency
S110A12C400BL (enhanced efficiency)
V110A12C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.7
85.0
13.7
Typ
88.5
86.2
240
14.3
12.7
±0.02
38.3
38.3
Max
Unit
%
300
14.9
13.5
±0.2
33.33
45
45
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
33.9
23.3
12
V
OUT
, 300W (e.g. S110A12C300BL, V110A12C300BL)
Parameter
Efficiency
S110A12C300BL (enhanced efficiency)
V110A12C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.9
86.0
13.7
Typ
90.0
87.0
240
14.3
7.9
±0.02
28.8
28.8
Max
Unit
%
300
14.9
9
±0.2
25
33.8
33.8
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
I want to ask, can two MCUs safely access the same FM24C02? The two MCUs handle their own affairs separately, and need to exchange about 10 bytes of data to establish a connection. It is assumed that ...
[align=left][color=#000]I just came into contact with the tiva version and don't know how to use it, so I would like to ask for advice [/color][/align][align=left][color=#000]Thinking: Use tiva ADC to...
After the installation is complete, I run DXP.EXE. The software screen flashes, and then nothing happens. There is no process. Has anyone encountered a similar situation? Please help~...
"sin.asm", WARNING! at line 1013: [W0000] Defined symbol '_FPUcosTable' cannot have a .ref .ref _FPUcosTable What does this warning mean? How can I fix it?...
After the AD software was upgraded to AD17 and AD18, some customers still used the Keep-Out layer to draw the shape or mechanical holes (strip slots) with the software drawing board. When it is opened...
This program is written to simulate the serial port hardware mechanism. When used, a timed interrupt can be set with a time interval of 1/4 baud rate. The receiving function is called once for ea...[Details]
introduction
With the continuous optimization of surface mount technology (SMT) and the rapid development of chip component manufacturing technology, the application of chip mounters in the el...[Details]
1. Introduction
Automobile pollution is one of the most important issues that people are most concerned about and need to solve urgently. As an important method for detecting automobile exhau...[Details]
This paper designs a dot matrix LED text display screen that is easy to update, expandable, and low-cost. The way to reduce costs is
① Use the Bluetooth data transmission function of mobile ph...[Details]
DSP (digital signal processor) is used more and more frequently in today's engineering applications. There are three main reasons for this: first, it has powerful computing power and is capable of ...[Details]
PV inverter manufacturer SMA has launched its first DC arc fault circuit interrupter (AFCI) PV inverter and has received UL certification.
The new SunnyBoy AFCI inverter models include 3000-US...[Details]
Smart lighting control systems provide high controllability for various buildings and further enhance the level of green energy. They are the core products of energy conservation and digital techn...[Details]
With the continuous consumption of earth's energy and the scarcity of resources, the harm of greenhouse effect to human beings, and the serious pollution of the atmosphere to the earth, the intern...[Details]
The traditional display screen using 51 single-chip microcomputer to control LED dot matrix has relatively simple functions. If it is to achieve diversified functions, it often takes a lot of time ...[Details]
FPGAs are used in 81% of electronic systems, including many commercial and defense products, and most FPGAs use BGA packaging. The BGA packaging is characterized by small solder balls and small sol...[Details]
In today's body control module (BCM) designs, savvy engineers are moving away from electromechanical relays whenever possible. Their next step is to eliminate fuses. But is eliminating fuses a nece...[Details]
Spatial Division Multiplexing (SDM) MIMO processing can significantly improve spectrum efficiency and thus greatly increase the capacity of wireless communication systems. Spatial Division Multip...[Details]
LED light sources have many environmental advantages, but early products still have certain technical bottlenecks in heat dissipation and high brightness design that cannot be broken through....[Details]
1 Embedded Systems
Embedded System refers to a collection of computer hardware and software with specific functions or purposes, which is divided into embedded software system and embe...[Details]
The production process of lithium batteries does not mention the previous processes such as material preparation, winding, liquid injection, and packaging, but only talks about the final formation ...[Details]