EEWORLDEEWORLDEEWORLD

Part Number

Search

GPFM125B

Description
Switching Power Supplies 125W 4 Output +5V/+12V/12V/-5V
CategoryPower/power management   
File Size222KB,2 Pages
ManufacturerSL Power
Download Datasheet Parametric Compare View All

GPFM125B Online Shopping

Suppliers Part Number Price MOQ In stock  
GPFM125B - - View Buy Now

GPFM125B Overview

Switching Power Supplies 125W 4 Output +5V/+12V/12V/-5V

GPFM125B Parametric

Parameter NameAttribute value
Product CategorySwitching Power Supplies
ManufacturerSL Power
RoHSNo
ProductSwitching Supplies
Output Voltage-Channel 15 VDC
Output Voltage-Channel 212 VDC
Number of Outputs4 Output
Output Power125 W
Open Frame/EnclosedOpen Frame
Input Voltage90 VAC to 264 VAC
Output Current-Channel 19 A
Output Current-Channel 24 A
IndustryMedical
Mounting StylePanel
Length6 in
Width3.5 in
Height1.5 in
ApprovalsEN60601-1
Load RegulationRegulated
Output Current-Channel 32.5 A
Output Voltage-Channel 312 VDC
Factory Pack Quantity15
Unit Weight1.250 lbs
GPFC125 Commercial/GPFM125
Medical
125 Watt Global Performance Switchers
FEATURES:
Compact 125 watt multiple output
Power density of 4 watts per cubic inch
Power Factor Correction to meet EN61000-3-2
Small package 6.00 x 3.5 x 1.5 inches
Conducted EMI exceeds FCC Class B and CISPR 22
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
• Commercial approved to UL1950, IEC950, CSA22.2
No. 950 and EN60950.
• Medical approved to UL2601-1, IEC601-1, CSA22.2
No. 601.1, EN60601-1
marked to LVD
SPECIFICATIONS:
Ac Input
90-264 Vac, 47-63 Hz single phase.
Remote Sense
Provided as a standard feature on V1 of all models.
Input Current
Maximum input current 2A at 90 Vac, 60 Hz with full rated load.
Input current harmonic content meets the requirements of
IEC1000-3-2. Active circuitry provides high power factor as
listed at .96 min., .99 typical. All data taken with full output
loading.
Temperature Range
0 to 50 °C at full rated output power. For operation above 50 °C,
derate output power and current by 2.5 % per °C.
Altitude
Operating:
Non-Operating
-500 to 10,000 ft. MSL
-500 to 40,000 ft MSL
DC Output Power
125 W with 150 LFM of air, 50 W convection cooled, 80 W
convection cooled with unit mounted to min. 12 x 12 x .125 in.
thick aluminim plate. Peak ratings are for 60 s maximum
duration, 10% duty cycle. With optional cover installed,125 W,
200 LFM airflow is required(-C suffix).
Shock and Vibration
All models are designed to meet the following specifications;
Random Vibration -
Operating: 0.003 g
2
/Hz, 1.5 g
rms
overall, 3 axes, 10 min. / axis
Non-Operating: 0.026 g
2
/Hz, 5.0 g
rms
overall, 3 axes, 1 hr. / axis
Shock -
Operating: Half-sine, 20 g
pk
, 10 ms, 3 axes, 6 shocks total
Non-Operating: Half-sine, 40 g
pk
, 10 ms, 3 axes, 6 shocks total
Inrush Current
Inrush 240 Vac is less than 37 A, averaged over the first ac
half-cycle under cold start conditions. Limiting provided by
internal thermistors.
Input Protection
Internal ac fuse provided on all models. Fuse does not blow on
overload or short circuit — fuse blows only if a catastrophic
failure occurs in the unit.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the EMC
requirements below.
EMI SPECIFICATIONS
COMPLIANCE LEVEL
Conducted Emissions-GPFC125
Conducted Emissions-GPFM125
Static Discharge
RF Field Susceptibility
Fast Transients / Bursts
Surge Susceptibility
Conducted RF Susceptibility
Voltage Sags & Surges
Line Frequency Harmonics
EN55022, Class B; FCC Class B
EN55011,Class B; FCC Class B
EN61000-4-2, 6 kV contact 8 kV air
EN61000-4-3, 3V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
EN61000-4-6, 3V
EN61000-4-11
EN61000-3-2 Class A
Efficiency
72 to 85% at full rated load. Depending upon model and load
distribution.
Minimum Load
Supply will function with no load on any output. To maintain
regulation with full load on V2, 3 and 4 output V1 requires a
minimum load of (2A + V4 current). Lower minimum load may be
obtained if less then full load is drawn from auxiliary outputs.
Overload Protection
Fully protected against short circuit and output overload. Total
output power limited to approximately 150 Watts. Cycling type
limits on output 1, 2 & 3, linear fold back on output 4. Recovery
after fault is automatic.
Overvoltage Protection
Built in on all models - See Output table for individual model
output limits.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode.
Transient Response
500 ms typical response time for return to within 0.5% of final
value for a 50% load step change,
∆i/∆t<
0.2 A ms. Maximum
voltage deviation is 3.5%.
Temperature Coefficient
0.03% / °C typical on all outputs.
Commercial Safety Approvals
All models are approved to UL1950, CSA22.2 No. 950-95,
IEC950, EN60950. CB certificate available. Exceeds FCC and
CISPR22 Class B conducted emissions requirement
Medical Safety Approvals
All models are Certified to be in compliance with the applicable
requirements of UL2601, CSA 22.2 No. 601.1-M90, IEC 601-1
(1988), EN 60601-1: 1990. CB certificate available.
Leakage Current
The maximum leakage current is as follows:
Test Condition
Normal
Single Fault
132 Vac @ 60 Hz input
70 µA
120 µA
264 Vac @ 50 Hz input
130 µA
240 µA
52
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com

GPFM125B Related Products

GPFM125B GPFM125GG GPFC125DG GPFM125A
Description Switching Power Supplies 125W 4 Output +5V/+12V/12V/-5V Switching Power Supplies 125W 4 Output MEDICAL Switching Power Supplies 125W +5/+24/+12/-12 Switching Power Supplies 125W 4 Output +5V/+12V/12V/-12V
Product Category Switching Power Supplies Switching Power Supplies Switching Power Supplies Switching Power Supplies
Manufacturer SL Power SL Power SL Power SL Power
RoHS No Details Details No
Product Switching Supplies Switching Supplies Switching Supplies Switching Supplies
Output Voltage-Channel 1 5 VDC 5 VDC 5 VDC 5 VDC
Output Voltage-Channel 2 12 VDC 3.3 VDC 24 VDC 12 VDC
Number of Outputs 4 Output 4 Output 4 Output 4 Output
Output Power 125 W 125 W 45 W 125 W
Open Frame/Enclosed Open Frame Open Frame Open Frame Open Frame
Input Voltage 90 VAC to 264 VAC 90 VAC to 264 VAC 90 VAC to 264 VAC 90 VAC to 264 VAC
Output Current-Channel 1 9 A 9 A 9 A 9 A
Output Current-Channel 2 4 A 7 A 3 A 4 A
Industry Medical Medical Commercial Medical
Mounting Style Panel Chassis Panel Panel
Length 6 in 6 in 6 in 6 in
Width 3.5 in 3.5 in 3.5 in 3.5 in
Height 1.5 in 1.5 in 1.5 in 1.5 in
Approvals EN60601-1 EN60601-1 EN60950-1 EN60601-1
Load Regulation Regulated Regulated Regulated Regulated
Output Current-Channel 3 2.5 A 2.5 A 2.5 A 4 A
Output Voltage-Channel 3 12 VDC 12 VDC 12 VDC 12 VDC
Factory Pack Quantity 15 - 1 15
Unit Weight 1.250 lbs - 1.250 lbs 1.250 lbs
ADI16365 Data Sheet
Please download if needed...
fl090726 ADI Reference Circuit
[Raspberry Pi Pico Review]——by fxyc87
@fxyc87[Raspberry Pi Pico Review] - Unboxing + Download [Raspberry Pi Pico Review] - Start Programming [Raspberry Pi Pico Review] - Start compiling the program 2 [Raspberry Pi Pico Review] - How to sa...
okhxyyo DIY/Open Source Hardware
High score for wireless network data transmission problem
I want to use the 802.11 protocol to perform point-to-point data transmission between two laptops, based on a C/S structure, with one laptop running a server program and the other laptop running a cli...
思想者 Embedded System
Is it necessary to set GPIOF4 high when booting from flash?
After the flash was successfully burned, I suddenly remembered that the GPIOF4 pin on my board was not set high.I read in most materials that if you want to boot from flash, you must set GPIOF4 high.N...
lijiamin11 Microcontroller MCU
What issues regarding antenna isolation should we pay attention to?
This article will be divided into three parts to explain the definition of antenna isolation, several key factors affecting antenna isolation, and how to improve the isolation of terminal antennas. I ...
btty038 RF/Wirelessly
A Brief Analysis of UWB Ultra-Wideband Indoor Positioning Technology
With the development of wireless communication technology and the improvement of data processing capabilities, location-based services have become one of the most promising Internet services. Whether ...
石榴姐 Robotics Development

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2008  824  1027  2598  2203  41  17  21  53  45 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号