Parameter NameAttribute value
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Is SamacsysN
Other featuresCOIL OPERATE VOLTAGE(AC): 20.4 V
body width35.7 mm
body height54.8 mm
Body length or diameter38.9 mm
Coil resistance176 Ω
Maximum coil voltage (AC)24 V
Contact (AC) maximum rated R load10A@240VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@28VDC
Maximum contact voltage (AC)240 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
Installation featuresPANEL MOUNT
operating hours25 ms
Maximum operating temperature70 °C
Minimum operating temperature-45 °C
physical size38.9mm x 35.7mm x 54.8mm
GuidelineUL
Relay actionLATCHED
Relay functionDPDT
Relay typePOWER/SIGNAL RELAY
release time25 ms
sealDUST PROOF
surface mountNO
Termination typeQUICK CONNECT
Base Number Matches1
General Purpose Relays
Industrial Relays
KUL Series Latching Panel Plug-in Relay
n
n
n
n
n
Potter & Brumfield
Magnetic latching relay
Single or dual wound DC coils or single wound AC coils
1, 2, and 3 pole Form C contact arrangement
Reset occurs by reversing polarity in a single coil relay or by
energizing the reset winding in dual coil relays
Various mounting and socket styles
Typical applications
Alarm systems, machine tools, battery chargers, process and power
controls, pressure washers, paving equipment
Approvals
UL E22575; CSA LR15734
Technical data of approved types on request
Contact Data
Contact arrangement
1 form C (CO), 2 form C (CO), 3 form C (CO)
Rated voltage
240VAC
Rated current
10A
Contact material
Ag
AgCdO
Min. recommended contact load
100mA, 12VDC 300mA, 12VDC
Frequency of operation
360 ops./hour
Operate/release time max.
25/25ms
Contact ratings
Type
Load
UL 508
Ag
5A, 240VAC
1/6HP, 120VAC
1/3HP, 240VAC
0.5A, 120VDC
2.5A, 120VAC, tungsten
AgCdO
10A, 250VAC
1/3HP, 120VAC
1/2HP, 250VAC
5A, 120VAC, tungsten
0.5A, 125VDC
10A, 28VDC
10FLA, 30LRA, 125VAC
5FLA, 15LRA, 250VAC
125VA, pilot duty, 125/250VAC
Mechanical endurance
10x10
6
ops.
Cycles
100x10
3
Coil versions, DC coil 1)
Coil
Rated
code
voltage
VDC
Single coil
12
12
24
24
48
48
110
110
Dual coil 2)
12
12
24
24
48
48
110
110
Operate
voltage
VDC
9.0
18.0
36.0
82.5
9.0
18.0
36.0
82.5
Coil
resistance
Ω±10%
120
472
1800
10000
90
350
1400
7400
Rated coil
power
W
1.2
1.25
1.3
1.25
1.6
1.65
1.65
1.65
1) Latch and reset coil voltages and resistances are the same (unlike coils on request).
2) Dual coil available only with 1 or 2 form C contacts.
All figures are given for coil without preenergization, at ambient temperature +23°C.
100x10
3
100x10
3
Coil versions, AC coil 3)
Coil
Rated
Operate
Latch coil
code
voltage
voltage
resistance
VAC
VAC
Ω±15%
Single coil
24
24
20.4
176
120
120
102.0
3700
240
240
204.0
179000
Dual coil
24
24
20.4
100
120
120
102.0
2525
Reset coil
resistance
Ω±15%
250
2200
Reset coil
resistor
680
15000
68000
5600
3) AC coils use diodes. Diodes and resistors included inside relay with 1 and 2 Form C
contacts. For 3 Form C relay, the customer must furnish and wire diodes and resistors
externally (1N4007 is recommended diode).
All figures are given for coil without preenergization, at ambient temperature +23°C.
Insulation Data
Coil Data
12 to 110VDC (single and dual coil)
24 to 240VAC (single coil)
24 to 120VAC (dual coil)
Coil insulation system according UL
Class B
Coil voltage range
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
Initial insulation resistance
between insulated elements
500V
rms
1500V
rms
1500V
rms
100MΩ
08-2011, Rev. 0811
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1

KUL-11A15S-24 Related Products

KUL-11A15S-24 KUL-11D15D-48
Description KUL-11A15S-24=KU KUL-11D15D-48=KU
Is it Rohs certified? conform to conform to
package instruction ROHS COMPLIANT ROHS COMPLIANT
Reach Compliance Code compliant compliant
ECCN code EAR99 EAR99
Is Samacsys N N
body width 35.7 mm 35.7 mm
body height 54.8 mm 54.8 mm
Body length or diameter 38.9 mm 38.9 mm
Coil resistance 176 Ω 1400 Ω
Contact (AC) maximum rated R load 10A@240VAC 10A@240VAC
Maximum contact current (AC) 10 A 10 A
Maximum contact current (DC) 10 A 10 A
Contact (DC) maximum rated R load 10A@28VDC 10A@28VDC
Maximum contact voltage (AC) 240 V 240 V
Maximum contact voltage (DC) 28 V 28 V
Contact/Output Power Type AC/DC AC/DC
Electrical life 100000 Cycle(s) 100000 Cycle(s)
Installation features PANEL MOUNT PANEL MOUNT
operating hours 25 ms 25 ms
Maximum operating temperature 70 °C 50 °C
Minimum operating temperature -45 °C -45 °C
physical size 38.9mm x 35.7mm x 54.8mm 38.9mm x 35.7mm x 54.8mm
Guideline UL UL
Relay action LATCHED LATCHED
Relay function DPDT DPDT
Relay type POWER/SIGNAL RELAY POWER/SIGNAL RELAY
release time 25 ms 25 ms
seal DUST PROOF DUST PROOF
surface mount NO NO
Termination type QUICK CONNECT QUICK CONNECT
Base Number Matches 1 1
MATLAB simulation program based on LTE Turbo coding is urgently needed
The matlab simulation program based on LTE Turbo coding is in urgent need of a simulation...
carsonsheng Download Centre
Discussion on the solution of using smartphone to control curtains, door locks, air conditioners and other electrical appliances at home
[i=s]This post was last edited by hanskying666 on 2015-4-29 21:28[/i] If you use a smartphone to make an APP, the phone can be connected to the Internet, and you can click on this APP to control the o...
hanskying666 RF/Wirelessly
Why does the waveform oscillate after amplification?
The pulse waveform is amplified by an op amp, and the back end carries a capacitive load. The rise time, fall time and other parameters of the pulse waveform need to be changed according to the use re...
yichun417 Analog electronics
Does anyone have any good methods for debugging IIC drivers?
Does anyone have any good methods for debugging IIC drivers?...
heyong Embedded System
Automotive buses: The quest for more bandwidth
Pipeline: It's a fluid dynamics term, and its connection to microprocessors and software seems a bit distant. But in the next decade, "pipeline" will become an electronic word. It will mean that autom...
frozenviolet Automotive Electronics
Differences between stepper motors and servo motors
[i=s]This post was last edited by paulhyde on 2014-9-15 03:33[/i] Stepper motors control the rotation angle by controlling the number of pulses, one pulse corresponds to one step angle. The equipment ...
windowsxd Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1348  558  612  2701  634  28  12  13  55  47 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号