MOS FET Relays
Special SOP4-pin package with
Dielectric strength AC 3.75 kV
• Trigger LED forward current of 2 mA (maximum)
facilitates power saving designs and prolonged battery
life.
• Continuous load current of 70 mA.
RoHS compliant
Refer to
“Common Precautions”.
Note:
G3VM-61VY
■
Application Examples
• Broadband systems
• Security systems
• Industrial equipment
• Battery powered equipment
• Measurement devices
• Amusement machines
The actual product is marked differently from the image
shown here.
■
List of Models
Package
Contact form
Terminals
Load voltage (peak value)
(See the note.)
Model
G3VM-61VY
G3VM-61VY(TR)
Number per
stick
150
---
Number per
tape
---
3,000
Special SOP4 SPST-NO
Note:
Surface-mounting 60 V
terminals
The AC peak and DC value are given for the load voltage.
■
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
G3VM-61VY
4.4
±
0.25
3.6
±
0.2
2.5
±
0.2
0.15
Note:
The actual product is marked differ-
ently from the image shown here.
0.4
±
0.1
2.54
±
0.25
0.1
±
0.1
0.5min
7.0
±
0.4
Weight: 0.1 g
■
Terminal Arrangement/Internal Connections (Top View)
G3VM-61VY
4
3
4
3
OMRON logo
Pin 1 mark
1
2
1
2
Model name
LOT No.
Note:
The actual product is marked differently
from the image shown here.
■
Actual Mounting Pad Dimensions (Recommended Value, Top View)
G3VM-61VY
6 to 6.3
1.2
0.8
2.54
G3VM-61VY
■
Absolute Maximum Ratings (T
a
= 25°C)
Item
Input
LED forward current
Repetitive peak LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Output
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Connection temperature
Dielectric strength between input and
output (See note 1.)
Operating temperature
Storage temperature
Soldering temperature (10 s)
Symbol
I
F
I
FP
∆
I
F
/°C
V
R
T
j
V
OFF
I
O
∆
I
O
/°C
T
j
V
I-O
T
a
T
stg
---
Rating
50
1
−0.5
5
125
60
70
−0.7
125
3,750
−40
to +85
Unit
mA
A
mA/°C
V
°C
V
mA
mA/°C
°C
V
rms
°C
°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
T
a
≥
25°C
100
µs
pulses, 100 pps
T
a
≥
25°C
Measurement Conditions
G3VM-61VY
Note:
1.
The dielectric strength between the
input and output was checked by ap-
plying voltage between all pins as a
group on the LED side and all pins
as a group on the light-receiving
side.
−55
to +125
°C
260
■
Electrical Characteristics (T
a
= 25°C)
Item
Input
LED forward voltage
Reverse current
Capacity between terminals
Trigger LED forward current
Output
Maximum resistance with output ON
Current leakage when the relay is
open
Capacity between I/O terminals
Insulation resistance
Turn-ON time
Turn-OFF time
Symbol
V
F
I
R
C
T
I
FT
R
ON
I
LEAK
C
I-O
R
I-O
t
ON
t
OFF
Mini-
mum
1.0
---
---
---
---
---
---
1,000
---
---
Typical
1.15
---
30
0.6
25
1
0.4
---
1
0.5
Maxi-
mum
1.3
10
---
2
50
1000
---
---
5
5
V
µA
pF
mA
Ω
nA
pF
MΩ
ms
ms
Unit
Measurement
conditions
I
F
= 10 mA
V
R
= 5 V
V = 0, f = 1 MHz
I
O
= 70 mA
I
F
= 3 mA,
I
O
= 70 mA
V
OFF
= 60 V
f = 1 MHz, Vs = 0 V
V
I-O
= 500 VDC,
R
oH
≤
60%
I
F
= 3 mA, R
L
= 200
Ω,
V
DD
= 10 V (See note 2.)
V
OUT
I
F
Note:
2.
Turn-ON and Turn-OFF
Times
I
F
1
2
4
3
R
L
V
DD
V
OUT
10%
t
ON
90%
t
OFF
■
Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Load voltage (AC peak/DC)
Operating LED forward current
Continuous load current (AC peak/DC)
Operating temperature
Symbol
V
DD
I
F
I
O
T
a
---
---
---
−
20
Minimum
---
3
---
---
Typical
48
25
60
65
Maximum
V
mA
mA
°C
Unit
■
Engineering Data
Load Current vs. Ambient Temperature
G3VM-61VY
Load current (mA)
100
■
Safety Precautions
Refer to
“Common Precautions”
for all G3VM models.
80
60
40
20
0
−20
0
20
40
60
80
100
Ambient temperature (°C)