EEWORLDEEWORLDEEWORLD

Part Number

Search

FN389B-6-22

Description
DC Fans Fan DC 60x25mm 12V 25CFM Seal Slv Wire
CategoryThe connector    The connector   
File Size718KB,5 Pages
ManufacturerSchaffner
Environmental Compliance
Download Datasheet Parametric View All

FN389B-6-22 Online Shopping

Suppliers Part Number Price MOQ In stock  
FN389B-6-22 - - View Buy Now

FN389B-6-22 Overview

DC Fans Fan DC 60x25mm 12V 25CFM Seal Slv Wire

FN389B-6-22 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerSchaffner
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC 60939; EN 133200; UL; CSA
Connector typeMAINS POWER CONNECTOR
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings6A, 250VAC
Manufacturer's serial numberFN389B
Installation typePANEL
OptionsGENERAL PURPOSE
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
DATASHEET
IEC Inlet Filters FN 380
Versatile Filtered Power Entry Module
Rated currents up to 6 A
Single or dual-fuse holder
Fuses Ø 6.3 x 32 mm Ø 5 x 20 mm
2-pole rocker switch
General purpose application
Optional medical versions (B type)
The FN 380 power entry module combines an IEC
inlet, a mains filter with a single or dual fuse holder
and a 2-pole rocker switch. Choosing FN 380 product
line brings you the rapid availability of a standard
filter associated with the necessary safety
acceptances. Standard IEC connector filters are a
practical solution helping you to pass EMI system
approval in a short time. A wide selection on
amperage ratings, fuse options, mounting
possibilities and filters for medical applications are
designed to offer you the desired solution.
Approvals
Features and benefits
Good conducted attenuation performance, based
on chokes with high saturation resistance and
excellent thermal behavior
Front or snap-in mounting
Single or dual-fuse holder
USA Ø 6.3 x 32 mm or EU Ø 5 x 20 mm fuses
2-pole rocker switch
Custom-specific versions are available on request
Maximum continuous operating voltage
Operating frequency
Rated currents
High potential test voltage
250 VAC, 50/60 Hz
50 to 400 Hz
2 to 6 A @ 40 °C max.
P –> PE 2000 VAC for 2 sec (standard types)
P –> N 760 VAC for 2 sec
P –> PE 2500 VAC for 2 sec (B types)
IP40 according to IEC 60529
-25 °C to +85 °C (25/85/21)
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
UL 94 V-2 or better
550,000 hours
2-pole, dark not illuminated
Marking I - 0
Inrush current 51 A
6,000 on-off operations according to UL 1054, TV 5
10,000 on-off operations according to ENEC
50,000 cycles
6 A (4 A), 250 VAC*
6A, 125 VAC; 4 A, 250 VAC; 1/10 HP
6 A, 125 VAC; 4 A, 250 VAC; 1/10 HP
Blade terminals acc. DIN 46 244-A4.8-0.8 (do not
connect by soldering)
Technical specifications
Typical applications
Portable electrical and electronic equipment
Consumer goods
EDP and office equipment
Single-phase power supplies, switch-mode power
supplies
Test and measurement equipment
Medical equipment
Protection category
Temperature range (operation and storage)
Design corresponding to
Flammability corresponding to
MTBF @ 40°C/230V (Mil-HB-217F)
Function
Electrical specifications
Typical electrical schematic
Mechanical life
Switch ratings
Europe (ENEC)
USA (UL)
Canada (CSA)
Output connections
* Value in () relates to the inductive current charge: cos φ = 0.65
Wince development series of questions - 2, continue with series of questions 1
::OnDraw(CDC* pDC) { CbmpDoc* pDoc = GetDocument(); ASSERT_VALID(pDoc); // TODO: add draw code for native data here HGLOBAL hDIB = pDoc->GetHObject(); if (hDIB != NULL) // 获取 DIB是否空{ // LPSTR lpDibSec...
ytada Embedded System
【Multi-function handheld oscilloscope function meter】Progress report
Due to the out-of-town competition in July, the construction was delayed for many days and did not start until the end of July. The preliminary situation is as follows:1.EEWORLD has purchased all the ...
梦之旅 ADI Reference Circuit
One day's results + sample application experience
The samples I applied for yesterday arrived, and today the minimum system from Taobao also arrived. I was soldering patches in the lab by myself. This was my first time soldering patches. I soldered 4...
石玉 TI Technology Forum
About MSP430 interrupt mechanism
I am writing something about interrupts because of DC's invitation. I have only been in contact with 430 for a short time and can only share my own experience with you. Please forgive me if there are ...
fish001 Microcontroller MCU
Analog and digital circuits in PCB design
In a circuit, there are both analog circuits and digital circuits. So how do we connect the analog power supply and digital power supply, and the analog ground and digital ground? (In low-frequency ci...
静静地期待 PCB Design
PCB layout secrets that you can never learn from textbooks (attached: amplifier PCB wiring example)
[i=s] This post was last edited by ohahaha on 2017-11-10 16:20 [/i] I saw this article elsewhere, it's very good, I'll share it with you Author: Timothy Claycomb In the circuit design process, applica...
ohahaha PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2512  822  325  797  2724  51  17  7  55  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号