The UT54ACS74 and the UT54ACTS74 contain two indepen-
dent D-type positive triggered flip-flops. A low level at the
Preset or Clear inputs sets or resets the outputs regardless of the
levels of the other inputs. When Preset and Clear are inactive
(high), data at the D input meeting the setup time requirement
is transferred to the outputs on the positive-going edge of the
clock pulse. Following the hold time interval, data at the D
input may be changed without affecting the levels at the outputs.
The devices are characterized over full military temperature
range of -55°C to +125°C.
FUNCTION TABLE
INPUTS
PRE
L
H
L
H
H
H
CLR
H
L
L
H
H
H
CLK
X
X
X
↑
↑
L
D
X
X
X
H
L
X
OUTPUT
Q
H
L
H
1
PINOUTS
14-Pin DIP
Top View
CLR1
D1
CLK1
PRE1
Q1
Q1
V
SS
1
2
3
4
5
6
7
14
13
12
11
10
9
8
V
DD
CLR2
D2
CLK2
PRE2
Q2
Q2
14-Lead Flatpack
Top View
CLR1
D1
CLK1
PRE1
Q1
Q1
V
SS
1
2
3
4
5
6
7
14
13
12
11
10
9
8
V
DD
CLR2
D2
CLK2
PRE2
Q2
Q2
LOGIC SYMBOL
PRE1
CLK1
D1
CLR1
PRE2
CLK2
D2
CLR2
(4)
(3)
(2)
(1)
(10)
(11)
(12)
(13)
(9)
(8)
Q2
Q2
S
C1
D1
R
(5)
(6)
Q1
Q1
Q
L
H
H
L
H
Q
o
1
H
L
Q
o
Note:
1. The output levels in this configuration are not guaranteed to meet the minimum
levels for V
OH
if the lows at preset and clear are near V
IL
maximum. In
addition, this configuration is nonstable; that is, it will not persist when either
preset or clear returns to its inactive (high) level.
Note:
1. Logic symbol in accordance with ANSI/IEEE standard 91-1984 and IEC
Publication 617-12.
1
LOGIC DIAGRAM
PRE
CLR
Q
CLK
Q
D
2
OPERATIONAL ENVIRONMENT
1
PARAMETER
Total Dose
SEU Threshold
2
SEL Threshold
Neutron Fluence
LIMIT
1.0E6
80
120
1.0E14
UNITS
rads(Si)
MeV-cm
2
/mg
MeV-cm
2
/mg
n/cm
2
Notes:
1. Logic will not latchup during radiation exposure within the limits defined in the table.
2. Device storage elements are immune to SEU affects.
ABSOLUTE MAXIMUM RATINGS
SYMBOL
V
DD
V
I/O
T
STG
T
J
T
LS
Θ
JC
I
I
P
D
PARAMETER
Supply voltage
Voltage any pin
Storage Temperature range
Maximum junction temperature
Lead temperature (soldering 5 seconds)
Thermal resistance junction to case
DC input current
Maximum power dissipation
LIMIT
-0.3 to 7.0
-.3 to V
DD
+.3
-65 to +150
+175
+300
20
±10
1
UNITS
V
V
°C
°C
°C
°C/W
mA
W
Note:
1. Stresses outside the listed absolute maximum ratings may cause permanent damage to the device. This is a stress rating only, functional operation of the device at
these or any other conditions beyond limits indicated in the operational sections is not recommended. Exposure to absolute maximum rating conditions for extended
periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
SYMBOL
V
DD
V
IN
T
C
PARAMETER
Supply voltage
Input voltage any pin
Temperature range
LIMIT
4.5 to 5.5
0 to V
DD
-55 to + 125
UNITS
V
V
°C
3
DC ELECTRICAL CHARACTERISTICS
7
(V
DD
= 5.0V
±
10%; V
SS
= 0V
6
, -55°C < T
C
< +125°C); Unless otherwise noted, Tc is per the temperature range ordered.
SYMBOL
V
IL
PARAMETER
Low-level input voltage
1
ACTS
ACS
High-level input voltage
1
ACTS
ACS
Input leakage current
ACTS/ACS
Low-level output voltage
3
ACTS
ACS
High-level output voltage
3
ACTS
ACS
Short-circuit output current
2 ,4
ACTS/ACS
Output current
10
(Sink)
I
OH
Output current
10
(Source)
P
total
I
DDQ
ΔI
DDQ
Power dissipation
2, 8, 9
Quiescent Supply Current
Quiescent Supply Current Delta
ACTS
V
IN
= V
DD
or V
SS
I
OL
= 8.0mA
I
OL
= 100μA
I
OH
= -8.0mA
I
OH
= -100μA
V
O
= V
DD
and V
SS
V
IN
= V
DD
or V
SS
V
OL
= 0.4V
V
IN
= V
DD
or V
SS
V
OH
= V
DD
- 0.4V
C
L
= 50pF
V
DD
= 5.5V
For input under test
V
IN
= V
DD
- 2.1V
For all other inputs
V
IN
= V
DD
or V
SS
V
DD
= 5.5V
C
IN
C
OUT
Input capacitance
5
Output capacitance
5
ƒ
= 1MHz @ 0V
ƒ
= 1MHz @ 0V
15
15
pF
pF
1.9
10
1.6
mW/
MHz
μA
mA
-8
mA
.7V
DD
V
DD
- 0.25
-200
8
200
.5V
DD
.7V
DD
-1
1
CONDITION
MIN
MAX
0.8
.3V
DD
UNIT
V
V
IH
V
I
IN
V
OL
μA
0.40
0.25
V
V
OH
V
I
OS
I
OL
mA
mA
4
Notes:
1. Functional tests are conducted in accordance with MIL-STD-883 with the following input test conditions: V
IH
= V
IH
(min) + 20%, - 0%; V
IL
= V
IL
(max) + 0%, -
50%, as specified herein, for TTL, CMOS, or Schmitt compatible inputs. Devices may be tested using any input voltage within the above specified range, but are
guaranteed to V
IH
(min) and V
IL
(max).
2. Supplied as a design limit but not guaranteed or tested.
3. Per MIL-PRF-38535, for current density
≤
5.0E5 amps/cm
2
, the maximum product of load capacitance (per output buffer) times frequency should not exceed 3,765
pF/MHz.
4. Not more than one output may be shorted at a time for maximum duration of one second.
5. Capacitance measured for initial qualification and when design changes may affect the value. Capacitance is measured between the designated terminal and V
SS
at
a frequency of 1MHz and a signal amplitude of 50mV rms maximum.
6. Maximum allowable relative shift equals 50mV.
7. All specifications valid for radiation dose
≤
1E6 rads(Si).
8. Power does not include power contribution of any TTL output sink current.
9. Power dissipation specified per switching output.
10. This value is guaranteed based on characterization data, but not tested.
I probably learned about Texas Instruments when I was a freshman. At that time, I would tell my friends that "This Texas is not that Texas!" In the blink of an eye, I am already a senior. I can see th...
Why does it say that to read P1 port, P1 must be set to 1 first, otherwise it will be incorrect! I tried without adding the preceding code page and it worked! Why is this? Thank you!...
[p=30, null, left][color=rgb(17, 17, 17)][font=宋体][font=Verdana]The hospital call intercom system is one of the important equipment to improve the nursing level of the hospital. Its basic function is ...
[i=s] This post was last edited by lonerzf on 2014-8-17 17:58 [/i] Because I have used Butterworth second-order low-pass filters several times before. This time I will compare my previous solution wit...
I would like to ask you experts a question:Why is the 0805 package pad red? It is placed on the TOP layer, while most of the other pads are on the MULTI layer? Why is this?
If you draw a line on the B...
PV DC fuses are safety devices used to protect PV panels, inverters, and DC loads. To ensure their safety and reliability, they must be UL248 certified.
Before applying for UL248 certifi...[Details]
Dual-mode inverters can operate both in conjunction with the grid and independently. These inverters can inject excess energy from renewable energy and storage devices into the grid, and withdraw p...[Details]
In recent years, with the increasing demand for manufacturing and automated production management, industrial barcode scanners have gradually become an indispensable part of the industrial manufact...[Details]
Some time ago, I attended the 4th Energy Chemistry Forum of the Chinese Chemical Society and learned about high-energy-density and high-safety batteries. I would like to summarize and share this wi...[Details]
Electric vehicles are currently gaining momentum, but this is just a facade. Fuel-powered vehicles remain unchallenged. While electric vehicles boast unique advantages in environmental emissions an...[Details]
Electric motors and internal combustion engines of the same power have similar torque levels. High power requires high torque, and torque determines a vehicle's acceleration speed, commonly known a...[Details]
Limited vocabulary recognition
According to the number of characters, words or short sentences in the vocabulary, it can be roughly divided into: less than 100 is small vocabulary; 100-1000 is...[Details]
summary
There are multiple approaches to making industrial systems more intelligent, including applying artificial intelligence (AI) technology at the edge and in the cloud to sensor...[Details]
As time goes by, people are increasingly concerned about their own and their families' health. However, existing monitoring devices for individual vital signs have struggled to gain market share du...[Details]
With the rapid advancement of automation technology, collaboration between robots is no longer just science fiction. Imagine dozens of machines moving goods in a warehouse without interfering with ...[Details]
Recently, South Korean robotics giant WIRobotics launched its first general-purpose humanoid robot, ALLEX, at the Robotics Innovation Center (RIH) at the Korea University of Science and Technology....[Details]
introduction
The concept of the smart home is gradually developing and gaining market acceptance. We believe its ultimate form lies in the interconnection of all home appliances through open i...[Details]
In daily life, power transformers have different functions and uses due to different usage scenarios. The most common ones can be divided into: control transformers, isolation transformers, rectifi...[Details]
"We have successfully launched the first version of our dedicated chip for EMB brake-by-wire. Second-generation samples have also been successfully completed, and we are actively planning a third-g...[Details]
Methods of DC motor speed regulation:
1. The voltage regulator can be used to change the input voltage and speed directly, which is often used for large kilowatt-level motors.
2. Thyristo...[Details]