EEWORLDEEWORLDEEWORLD

Part Number

Search

MI-P53-IAW

Description
Military Chassis Mount DC-DC Converters 10 to 300W Single, Dual, Triple Outputs
File Size129KB,4 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet View All

MI-P53-IAW Overview

Military Chassis Mount DC-DC Converters 10 to 300W Single, Dual, Triple Outputs

MI - MegaMod
TM
Family
Military Chassis Mount DC-DC Converters 10 to 300W
Single, Dual, Triple Outputs
Features
Inputs:
28, 155, 165 and 270Vdc
Any output: 2 to 48Vdc
Up to 13.5W/in
3
High efficiency
Size — 1- up half-size: 2.58" x 2.5" x 0.62"
(65,5 x 63,5 x 15,7mm)
Size — 1- up full-size: 4.9" x 2.5" x 0.62"
(124,5 x 63,5 x 15,7mm)
Size — 2- up half-size: 2.58" x 4.9" x 0.62"
(65,5 x 124,5 x 15,7mm)
Size — 2- up full-size: 4.9" x 4.9" x 0.62"
(124,5 x 124,5 x 15,7mm)
Size — 3- up half-size: 2.58" x 7.3" x 0.62"
(65,5 x 185,4 x 15,7mm)
Size — 3- up full-size: 4.9" x 7.3" x 0.62"
(124,5 x 185,4 x 15,7mm)
Product Highlights
Vicor’s MI-MegaMod family
of single, dual, and triple output
DC-DC converters provide power
system designers with cost-
effective, high-performance, off-
the-shelf solutions to applications
that might otherwise require a
custom supply.
Incorporating standard MI-200
or MI-J00 family converters in
rugged, chassis mount packages,
MegaMods can be ordered with
single, dual, or triple outputs,
having a combined output power
of up to 300W. Totally isolated
outputs eliminate efficiency
penalties and output interaction
problems.
Remote sense
ZVS/ZCS power architecture
Low noise FM control
Configuration Chart
Full-Size MegaMods
Single Output
MI-L
MI-M
MI-N
Dual Output
MI-P
MI-Q
Triple Output
MI-R
Number of
Modules
1
2
3
2
3
3
50 – 100W
150 – 200W
300W
100 – 200W
200 – 300W
150 – 300W
4.9" x 2.5" x 0.62"
4.9" x 4.9" x 0.62"
4.9" x 7.3" x 0.62"
4.9" x 4.9" x 0.62"
4.9" x 7.3" x 0.62"
4.9" x 7.3" x 0.62"
Half-Size MegaMods
Single Output
MI-LJ
Dual Output
MI-PJ
Triple Output
MI-RJ
10 – 50W
20 – 100W
30 – 150W
2.58" x 2.5" x 0.62"
2.58" x 4.9" x 0.62"
2.58" x 7.3" x 0.62"
1
2
3
Input Voltage
Nominal Range Transient
2 =28Vdc
5 =155Vdc
6 =270Vdc
7 =165Vdc
18 –
60V
100 – 210V 230V
125 – 400V
(2)
475V
100 – 310V
(3)
50V
(1)
Output Voltage
Z = 2V
Y = 3.3V
0 = 5V
X = 5.2V
W= 5.5V
V = 5.8V
T = 6.5V
R = 7.5V
M = 10V
1 = 12V
P = 13.8V
2 = 15V
N = 18.5V
3 = 24V
L = 28V
J = 36V
K = 40V
4 = 48V
Product Grade
Full-Size
I = –40°C to +85°C
M = –55°C to +85°C
Half-Size
I = –40°C to +100°C
M = –55°C to +100°C
Output Power/Current
Full-Size
Half-Size
≥5V
<5V
≥5V
<5V
Y
X
W
V
= 50W 10A A = 10W —
= 75W 15A Z = 25W 5A
= 100W 20A Y = 50W 10A
= — 30A
Output Power/Current
≥5V
<5V
V
U
S
=
=
=
150W
200W
30A
60A
Output Power/Current
≥5V
<5V
S
P
=
=
300W
90A
(1)
(2)
(3)
16V operation at 75% load.
These units rated at 75% load from 125 – 150Vin: Full-size – 5Vout @ 100W; 2Vout and 3.3Vout @ 30A
Half-Size – 5Vout @ 50W; 2V and 3.3V @ 10A.
For use with Vicor’s MI-AIM
MI-MegaMod 10/02
1 of 4
When I saw the experts explaining signals and systems and digital signal processing, I finally understood what my university major was about! ! (Part 3)
[b]What is the sampling theorem for in Lesson 3?[/b] 1. For example, when making a phone call, the signal sent by the phone is PAM pulse amplitude modulation. What is transmitted on the phone line is ...
季夏木槿 MCU
How to transfer files between two PSP machines via adhoc
I have read many documents before, which are about how to connect to http/ftp, but now I want to implement a program to transfer files between two machines, similar to adhoc file transfer. I hope you ...
czhd1977 Embedded System
About MATLAB and ISE Joint Simulation
[i=s]This post was last edited by xpfshawn on 2017-12-26 21:49[/i] I used the system generator to link ISE and MATLAB, but when I opened simulink, the following situation appeared I followed the proce...
xpfshawn FPGA/CPLD
Recommend a book to newbies like me who are just starting out
A book I bought called "Windows CE Device Driver and BSP Development Guide" finally arrived today (the speed was good, it arrived in three days). I flipped through it and paid attention to the BSP par...
jgalz Embedded System
Ask for points
How can I get points? I registered an account but never successfully downloaded any files....
divdir Talking
How to implement CV, CC and CR modes inside a DC electronic load
[align=left][color=rgb(51, 51, 51)][backcolor=white][font=Calibri, sans-serif][size=11pt]In terms of function, electronic loads and power supplies are completely opposite. Power supplies are used to p...
wstt Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1427  1424  781  134  1409  29  16  3  52  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号