Description
AC Power Entry Modules 0.5A 250VAC INLET FILTER
CategoryThe connector   
File Size432KB,6 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet Parametric View All

50082010 Online Shopping

Suppliers Part Number Price MOQ In stock  
50082010 - - View Buy Now

50082010 Overview

AC Power Entry Modules 0.5A 250VAC INLET FILTER

50082010 Parametric

Parameter NameAttribute value
Product CategoryAC Power Entry Modules
ManufacturerSCHURTER
RoHSDetails
ProductInlets
FilteredFiltered
FusedNo
Switch FunctionNot Switched
Current Rating500 mA
Voltage Rating250 V
Mounting StyleSnap In
Termination StyleQuick Connect
Connector TypeC-8
Filter TypeStandard
PackagingBulk
Housing MaterialThermoplastic
Factory Pack Quantity20
Unit Weight0.609887 oz
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
5008
IEC Appliance Inlet C8 with Filter, Front Side Mounting
Snap-in mounting from front side
Screw-on mounting from front side
C8
70° C
Approvals and Compliances
Description
- Panel Mount :
Screw-on or snap-in mounting from front side
- 2 Functions :
Appliance Inlet Protection class II , Line filter in standard and medical
version
- Solder terminals or quick connect terminals
Characteristics
- Compact high performance filter
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
References
Weblinks
- Standard version without X-capacitor
- Polarized C8 connector
Alternative: version without line filter
2576; 2578
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
0.5 - 2.5 A @ Ta 40 °C / 250 VAC; 50 Hz
0.5 - 6 A @ Ta 40 °C / 250 VAC; 60 Hz
> 1.7 kVDC between L-N
> 4 kVDC between L/N-PE
Test voltage (2 sec)
> 2.5 kV between L-N
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class II acc. to IEC 61140
solder pin or quick connect terminals
6.3 x 0.8 or 4.8 x 0.8 mm
Screw
Mounting screw torque max 0.5 Nm
Snap-in 1 mm to 3 mm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
C8 acc. to IEC 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C,
2.5 A, Protection Class II
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 6'700'000 h acc. to MIL-HB-217 F
Line Filter
Impulse Withstand Voltage
Allowable Operation Tempe-
rature
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness S
MTBF
Material: Housing
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: 5008
Approval Logo
Certificates
VDE Approvals
UL Approvals
Certification Body
VDE
UL
Description
Certificate Number: 40029278
UL File Number: E72928
EMC Products
1
Power factor correction principle and related IC
OverviewIn recent years, with the development of electronic technology, the demand for various office automation equipment, household appliances, and computers has increased year by year. These device...
zbz0529 Test/Measurement
I would like to ask some questions about the OSD layer
Now I want to set up a part of OSD QT transparent reading registers. I need to configure OSDWIN0MD.TE0 TRANSPVALL.RGBL. I know OSDWIN0MD.OMD= 01[/color][/size][/font] [font=微软雅黑][size=5][color=#0000ff...
力量 DSP and ARM Processors
How to display "previous bookmark" and "next bookmark" in the bookmark function (Bookmarks) in CCS?
How to display "previous bookmark" and "next bookmark" in the bookmark function (Bookmarks) in CCS?...
Jungle Microcontroller MCU
Celebrate your account upgrade~
Finally got rid of the sand and evolved into silicon crystal. . Today is 520, and the points happen to be 520. Haha, I'm pretty happy~ ~~~...
okhxyyo Talking
EEWORLD University Hall----Achieving a new generation of test and measurement applications
Realizing the next generation of test and measurement applications : https://training.eeworld.com.cn/course/5546...
hi5 Power technology
Please help me with the slow running of CE
Since HIVE REGISTER was added, the system has been running very slowly. After removing HIVE, it is OK. I would like to ask, has anyone encountered similar problems? How to solve them? Which function i...
diedong123 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 753  191  938  2209  1629  16  4  19  45  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号