High CMR Line Receiver
Optocouplers
Technical Data
HCPL-2602
HCPL-2612
Features
• 1000 V/
µ
s Minimum Common
Mode Rejection (CMR) at
V
CM
= 50 V for HCPL-2602
and 3.5 kV/
µ
s Minimum
CMR at V
CM
= 300 V for
HCPL-2612
• Line Termination Included –
No Extra Circuitry Required
• Accepts a Broad Range of
Drive Conditions
• LED Protection Minimizes
LED Efficiency Degradation
• High Speed: 10 MBd
(Limited by Transmission
Line in Many Applications)
• Guaranteed AC and DC
Performance over
Temperature: 0
°
C to 70
°
C
• External Base Lead Allows
“LED Peaking” and LED
Current Adjustment
• Safety Approval
UL Recognized – 2500 V rms
for 1 Minute
CSA Approved
• MIL-STD-1772 Version
Available (HCPL-1930/1)
Applications
• Isolated Line Receiver
• Computer-Peripheral
Interface
• Microprocessor System
Interface
• Digital Isolation for A/D,
D/A Conversion
• Current Sensing
• Instrument Input/Output
Isolation
• Ground Loop Elimination
•
Pulse Transformer
Replacement
• Power Transistor Isolation
in Motor Drives
Description
The HCPL-2602/12 are optically
coupled line receivers that
combine a GaAsP light emitting
diode, an input current regulator
and an integrated high gain photo
detector. The input regulator
serves as a line termination for
line receiver applications. It
clamps the line voltage and
regulates the LED current so line
reflections do not interfere with
circuit performance.
The regulator allows a typical
LED current of 8.5 mA before it
starts to shunt excess current.
The output of the detector IC is
Functional Diagram
NC
IN+
IN–
CATHODE
1
2
3
4
8
7
6
5
V
CC
V
E
V
O
GND
LED
ON
OFF
ON
OFF
ON
OFF
TRUTH TABLE
(POSITIVE LOGIC)
ENABLE
H
H
L
L
NC
NC
OUTPUT
L
H
H
H
L
H
SHIELD
A 0.1
µF
bypass capacitor must be connected between pins 5 and 8.
CAUTION: It is advised that normal static precautions be taken in handling and assembly of this component to
prevent damage and/or degradation which may be induced by ESD.
1-314
5965-3585E
an open collector Schottky
clamped transistor. An enable
input gates the detector. The
internal detector shield provides a
guaranteed common mode
transient immunity specification
of 1000 V/µs for the 2602, and
3500 V/µs for the 2612.
DC specifications are defined
similar to TTL logic. The
optocoupler ac and dc operational
parameters are guaranteed from
0°C to 70°C allowing trouble-free
interfacing with digital logic
circuits. An input current of 5 mA
will sink an eight gate fan-out
(TTL) at the output.
The HCPL-2602/12 are useful as
line receivers in high noise
environments that conventional
line receivers cannot tolerate. The
higher LED threshold voltage
provides improved immunity to
differential noise and the internally
shielded detector provides orders
of magnitude improvement in
common mode rejection with little
or no sacrifice in speed.
Selection Guide
Minimum CMR
dV/dt
(V/
µ
s)
NA
5,000
10,000
1,000
3,500
1,000
1,000
[2]
1,000
V
CM
(V)
NA
50
1,000
50
300
50
1,000
50
12.5
3
Input
On-
Current
(mA)
5
8-Pin DIP (300 Mil)
Output
Enable
YES
NO
YES
NO
YES
NO
YES
YES
YES
NO
YES
NO
[3]
Small-Outline SO-8
Single
Channel
Package
HCPL-0600
Dual
Channel
Package
HCPL-0630
HCPL-0601
Widebody
(400 Mil)
Single
Channel
Package
HCNW137
HCNW2601
Hermetic
Single and
Dual Channel
Packages
Single
Channel
Package
6N137
Dual
Channel
Package
HCPL-2630
HCPL-2601
HCPL-2631
HCPL-2611
HCPL-4661
HCPL-2602
[1]
HCPL-2612
[1]
HCPL-261A
HCPL-263A
HCPL-261N
HCPL-263N
HCPL-0631
HCPL-0611
HCPL-0661
HCNW2611
HCPL-061A
HCPL-063A
HCPL-061N
HCPL-063N
HCPL-193X
HCPL-56XX
HCPL-66XX
Notes:
1. HCPL-2602/2612 devices include input current regulator.
2. 15 kV/µs with V
CM
= 1 kV can be achieved using HP application circuit.
3. Enable is available for single channel products only, except for HCPL-193X devices.
1-315
Ordering Information
Specify Part Number followed by Option Number (if desired).
Example:
HCPL-2602#XXX
300 = Gull Wing Surface Mount Option
500 = Tape and Reel Packaging Option
Option data sheets available. Contact your Hewlett-Packard sales representative or authorized distributor for
information.
Schematic
+
2
I
I
I
F
I
CC
I
O
6
V
I
8
V
CC
V
O
–
3
90
Ω
SHIELD
I
E
5
7
V
E
GND
4
USE OF A 0.1 µF BYPASS CAPACITOR CONNECTED
BETWEEN PINS 5 AND 8 IS REQUIRED (SEE NOTE 1).
1-316
Package Outline Drawings
8-Pin DIP Package
9.65 ± 0.25
(0.380 ± 0.010)
8
7
6
5
TYPE NUMBER
DATE CODE
HP XXXX
YYWW RU
1
1.19 (0.047) MAX.
2
3
4
UL
RECOGNITION
7.62 ± 0.25
(0.300 ± 0.010)
6.35 ± 0.25
(0.250 ± 0.010)
1.78 (0.070) MAX.
+ 0.076
0.254 - 0.051
+ 0.003)
(0.010 - 0.002)
5° TYP.
4.70 (0.185) MAX.
0.51 (0.020) MIN.
2.92 (0.115) MIN.
1.080 ± 0.320
(0.043 ± 0.013)
0.65 (0.025) MAX.
2.54 ± 0.25
(0.100 ± 0.010)
DIMENSIONS IN MILLIMETERS AND (INCHES).
8-Pin DIP Package with Gull Wing Surface Mount Option 300
PAD LOCATION (FOR REFERENCE ONLY)
9.65 ± 0.25
(0.380 ± 0.010)
8
7
6
5
1.016 (0.040)
1.194 (0.047)
4.826 TYP.
(0.190)
6.350 ± 0.25
(0.250 ± 0.010)
9.398 (0.370)
9.906 (0.390)
1
2
3
4
1.194 (0.047)
1.778 (0.070)
1.780
(0.070)
MAX.
9.65 ± 0.25
(0.380 ± 0.010)
7.62 ± 0.25
(0.300 ± 0.010)
0.381 (0.015)
0.635 (0.025)
1.19
(0.047)
MAX.
4.19 MAX.
(0.165)
+ 0.076
0.254 - 0.051
+ 0.003)
(0.010 - 0.002)
1.080 ± 0.320
(0.043 ± 0.013)
0.635 ± 0.130
2.54
(0.025 ± 0.005)
(0.100)
BSC
DIMENSIONS IN MILLIMETERS (INCHES).
LEAD COPLANARITY = 0.10 mm (0.004 INCHES).
0.635 ± 0.25
(0.025 ± 0.010)
12° NOM.
1-317
Solder Reflow Temperature Profile (Gull Wing Surface Mount Option 300 Parts)
260
240
220
200
180
160
140
120
100
80
60
40
20
0
0
1
2
3
4
5
6
7
8
9
10
11
12
∆T
= 145°C, 1°C/SEC
∆T
= 115°C, 0.3°C/SEC
TEMPERATURE – °C
∆T
= 100°C, 1.5°C/SEC
TIME – MINUTES
Note: Use of nonchlorine activated fluxes is highly recommended.
Regulatory Information
The HCPL-2602/2612 have been
approved by the following
organizations:
UL
Recognized under UL 1577,
Component Recognition
Program, File E55361.
CSA
Approved under CSA Component
Acceptance Notice #5, File CA
88324.
Insulation and Safety Related Specifications
Parameter
Min. External Air Gap
(External Clearance)
Min. External Tracking
Path (External Creepage)
Min. Internal Plastic
Gap (Internal Clearance)
Tracking Resistance
(Comparative Tracking
Index)
Isolation Group
Symbol
L(I01)
L(I02)
Value
7.1
7.4
0.08
Units
mm
mm
mm
Conditions
Measured from input terminals to output terminals,
shortest distance through air.
Measured from input terminals to output terminals,
shortest distance path along body.
Through insulation distance, conductor to conductor,
usually the direct distance between the photoemitter
and photodetector inside the optocoupler cavity.
DIN IEC 112/VDE 0303 Part 1
CTI
200
V
IIIa
Material Group (DIN VDE 0110, 1/89, Table 1)
Option 300 - surface mount classification is Class A in accordance with CECC 00802.
1-318