Amphenol Canada Corp - Product Change Notice (PCN)
PCN Date
Supplier Name:
Amphenol Canada PCN-DN Number
Description of Change
January 29, 2009
Amphenol
PCN-DN-C052
Shield raw material change
Shield material for all the below mentioned series will be changed from copper alloy (brass) to
stainless steel (with tin dipped shield PCB tail).
Summary of changes between new and old part
Traceability guidelines (lot code / date code,
markings, ship date…)
Last Time Buy Date
Datasheet attached? & Filename(s)
Qual Test data attached? & Filename(s)
This will be a running change and as such inventories may contain both old and new versions. Date
code on the packaging tray.
See detail below
N/A
EMI performance test comparison between connectors with brass shield & stainless steel shield
attached. File: EMI test data-Brass shield & EMI test data-Stainless steel shield
Samples
PCN Effectivity
Availability
Date
Date
01-Mar-09
01-Mar-09
01-Mar-09
01-Mar-09
01-Mar-09
01-Mar-09
8 wks ARO
8 wks ARO
8 wks ARO
8 wks ARO
8 wks ARO
8 wks ARO
Expected
Supplier Qual
Date
N/A
N/A
N/A
N/A
N/A
N/A
Customer part
Number
Amphenol Existing Series and
Part Number Nomenclature
RJSA-XXXX-XXXX
RJSAE-XXXX-XXXX
RJSB-XXXX-XXXX
RJSBE-XXXX-XXXX
RJHS-XXXX-XXXX
RJHSE-XXXX-XXXX
Amphenol New Series and Part
Number Nomenclature
No Change
No Change
No Change
No Change
No Change
No Change
Last Time
Buy Date
28-Feb-09
28-Feb-09
28-Feb-09
28-Feb-09
28-Feb-09
28-Feb-09
Form #9011045, Rev A
BEST TESTING LAB.&Neutron Engineering Inc.
No.3.JinShaGang 1st Road,ShiXia,DaLang Town,DongGuan,China.
Tel: (0769)-8708-2000 Fax: (0769)-8708-2188 Post Code: 523792
Radiated Emission Measurement
File : Amphenol Sample
Data :#14
Date: 2006/01/12
Time:
下午
08:59:20
Site CB01-BTL
:
Limit: CISPR22 ClassB 3M Radiation
EUT: RJ45
M/N: No.1 ( with Brassiness shield )
Mode:
Note:
Reading
Level
dBuV
Polarization:
Horizontal
Power:
Distance:
3m
Temperature:
Humidity:
Air Pressure:
26
℃
60 %
983 hpa
No. Mk.
1 *
2 !
3 !
4
5
6
Freq.
MHz
Correct
Factor
dB
Measure-
ment
dBuV/m
Limit
dBuV/m
Over
dB
Detector
Comment
33.3750
36.7500
42.1500
58.3500
68.4750
83.3250
51.92
52.10
53.31
55.31
53.02
48.81
-13.51
-15.51
-18.26
-22.65
-22.94
-21.83
38.41
36.59
35.05
32.66
30.08
26.98
40.00
40.00
40.00
40.00
40.00
40.00
-1.59
-3.41
-4.95
-7.34
-9.92
-13.02
peak
peak
peak
peak
peak
peak
*:Maximum data
x:Over limit
!:over margin
Page: 1 o f 2
Engineer Signature:
●Reference
Only
File :
安費諾
\Data :#14
PDF created with FinePrint pdfFactory Pro trial version
www.pdffactory.com
BEST TESTING LAB.&Neutron Engineering Inc.
No.3.JinShaGang 1st Road,ShiXia,DaLang Town,DongGuan,China.
Tel: (0769)-8708-2000 Fax: (0769)-8708-2188 Post Code: 523792
Radiated Emission Measurement
File :安費諾
Data :#15
Date: 2006/01/12
Time:
下午
09:00:03
Site CB01-BTL
:
Limit: CISPR22 ClassB 3M Radiation
EUT: RJ45
M/N: No.1 ( with Brassiness shield )
Mode:
Note:
Reading
Level
dBuV
Polarization:
Horizontal
Power:
Distance:
3m
Temperature:
Humidity:
Air Pressure:
26
℃
60 %
983 hpa
No. Mk.
1
3
4
5
6
Freq.
MHz
Correct
Factor
dB
Measure-
ment
dBuV/m
Limit
dBuV/m
Over
dB
Detector
Comment
433.0000
576.5000
601.0000
672.7500
816.2500
45.30
44.72
43.46
41.40
39.70
39.66
-12.12
-10.19
-9.46
-8.45
-6.78
-5.48
33.18
34.53
34.00
32.95
32.92
34.18
47.00
47.00
47.00
47.00
47.00
47.00
-13.82
-12.47
-13.00
-14.05
-14.08
-12.82
peak
peak
peak
peak
peak
peak
2 * 529.2500
*:Maximum data
x:Over limit
!:over margin
Page: 2 o f 2
Engineer Signature:
●Reference
Only
File :
安費諾
\Data :#15
PDF created with FinePrint pdfFactory Pro trial version
www.pdffactory.com
BEST TESTING LAB.&Neutron Engineering Inc.
No.3.JinShaGang 1st Road,ShiXia,DaLang Town,DongGuan,China.
Tel: (0769)-8708-2000 Fax: (0769)-8708-2188 Post Code: 523792
Radiated Emission Measurement
File :
Data :#4
Date: 2006/01/12
Time:
下午
08:45:18
Site CB01-BTL
:
Limit: CISPR22 ClassB 3M Radiation
EUT: RJ45
M/N: No.1 ( with Stainless shield )
Mode:
Note:
Reading
Level
dBuV
Polarization:
Horizontal
Power:
Distance:
3m
Temperature:
Humidity:
Air Pressure:
26
℃
60 %
983 hpa
No. Mk.
1 *
2 !
3 !
4
5
6
Freq.
MHz
Correct
Factor
dB
Measure-
ment
dBuV/m
Limit
dBuV/m
Over
dB
Detector
Comment
33.3750
37.4250
44.1750
58.3500
68.4750
166.3500
49.96
50.35
54.54
56.27
53.07
48.26
-13.51
-15.88
-19.03
-22.65
-22.94
-20.08
36.45
34.47
35.51
33.62
30.13
28.18
40.00
40.00
40.00
40.00
40.00
40.00
-3.55
-5.53
-4.49
-6.38
-9.87
-11.82
peak
peak
peak
peak
peak
peak
*:Maximum data
x:Over limit
!:over margin
Page: 1 o f 2
Engineer Signature:
●Reference
Only
File :
安費諾
\Data :#4
PDF created with FinePrint pdfFactory Pro trial version
www.pdffactory.com
BEST TESTING LAB.&Neutron Engineering Inc.
No.3.JinShaGang 1st Road,ShiXia,DaLang Town,DongGuan,China.
Tel: (0769)-8708-2000 Fax: (0769)-8708-2188 Post Code: 523792
Radiated Emission Measurement
File :Amphenol Sample
Data :#5
Date: 2006/01/12
Time:
下午
08:46:02
Site CB01-BTL
:
Limit: CISPR22 ClassB 3M Radiation
EUT: RJ45
M/N: No.1 ( with Stainless shield )
Mode:
Note:
Reading
Level
dBuV
Polarization:
Horizontal
Power:
Distance:
3m
Temperature:
Humidity:
Air Pressure:
26
℃
60 %
983 hpa
No. Mk.
1
2
3
4
5
Freq.
MHz
Correct
Factor
dB
Measure-
ment
dBuV/m
Limit
dBuV/m
Over
dB
Detector
Comment
433.0000
529.2500
576.5000
672.7500
865.2500
46.21
43.33
41.76
38.56
38.03
36.88
-12.12
-10.19
-9.46
-6.78
-4.48
-1.80
34.09
33.14
32.30
31.78
33.55
35.08
47.00
47.00
47.00
47.00
47.00
47.00
-12.91
-13.86
-14.70
-15.22
-13.45
-11.92
peak
peak
peak
peak
peak
peak
6 * 996.5000
*:Maximum data
x:Over limit
!:over margin
Page: 2 o f 2
Engineer Signature:
●Reference
Only
File :
安費諾
\Data :#5
PDF created with FinePrint pdfFactory Pro trial version
www.pdffactory.com