Product data sheet
Characteristics
ZCKL18
limit switch body ZCKL - 1NC+1NO - snap
action - Cable gland include
Product availability: Non-Stock - Not normally stocked in distribution facility
Main
Commercial Status
Range of product
Series name
Product or component
type
Device short name
Body type
Product compatibility
Associated head
Commercialised
OsiSense XC
Standard format
Limit switch body
ZCKL
Fixed
XCKL
ZCKD02
ZCKD05
ZCKD06
ZCKD08
ZCKD10
ZCKD109
ZCKD15
ZCKD16
ZCKD17
ZCKD21
ZCKD219
ZCKD23
ZCKD239
ZCKD41
ZCKD59
ZCKD81
ZCKD91
ZCKD029
Metal
1 tapped entry for Pg 13.5 cable gland (included)
2
1 NC + 1 NO
Snap action
1 1 position
Gold plated contacts
Body material
Cable entry
Number of poles
Contacts type and
composition
Contacts operation
Number of steps
Contacts material
Complementary
Local display
Electrical connection
Positive opening
Minimum actuation speed
[Ie] rated operational current
[Ithe] conventional enclosed thermal current
[Ui] rated insulation voltage
Without
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
With
0.01 m/min
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
10 A
300 V conforming to CSA C22.2 No 14 contact block
500 V degree of pollution 3 conforming to IEC 60947-1 contact block
300 V conforming to UL 508 contact block
0.25 mOhm conforming to IEC 60255-7 category 3
6 kV conforming to IEC 60947-1
6 kV conforming to IEC 60664
10 A by gG cartridge fuse
5000000 cycles, DC-13 48 V, 7 W, operating rate: < 60 cyc/mn, load factor: 0.5
conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 24 V, 10 W, operating rate: < 60 cyc/mn, load factor: 0.5
conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 120 V, 4 W, operating rate: < 60 cyc/mn, load factor: 0.5
conforming to IEC 60947-5-1 appendix C
1
Resistance across terminals
[Uimp] rated impulse withstand voltage
Short circuit protection
Electrical durability
Feb 28, 2016
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Width
Height
Depth
Product weight
Terminals description ISO n°1
2.05 in (52 mm)
2.83 in (72 mm)
1.18 in (30 mm)
0.46 lb(US) (0.21 kg)
(13-14)NO
(21-22)NC
Environment
IP degree of protection
IK degree of protection
Ambient air temperature for operation
Ambient air temperature for storage
Environmental characteristic
IP65
IK08
-13...158 °F (-25...70 °C) for standard environment
-40...158 °F (-40...70 °C)
Standard environment
Ordering and shipping details
Category
Discount Schedule
GTIN
Nbr. of units in pkg.
Package weight(Lbs)
Product availability
Returnability
Country of origin
22416 - LIMIT SWITCHES,IEC,XCKL
T
00785901168898
1
0.80
Non-Stock - Not normally stocked in distribution facility
N
FR
Offer Sustainability
Sustainable offer status
RoHS
REACh
Product environmental profile
Product end of life instructions
Not Green Premium product
Will be Compliant on 3Q2013
Reference not containing SVHC above the threshold
Available
Download Product Environmental
Need no specific recycling operations
Contractual warranty
Period
18 months
2