EEWORLDEEWORLDEEWORLD

Part Number

Search

2200SG1F502A3HA

Description
Strain Guage Sensor, Gage, -15Psi Min, 0Psi Max, 0.25%, 0-10V, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size507KB,4 Pages
ManufacturerGems Sensors & Controls
Download Datasheet Parametric View All

2200SG1F502A3HA Overview

Strain Guage Sensor, Gage, -15Psi Min, 0Psi Max, 0.25%, 0-10V, Cylindrical

2200SG1F502A3HA Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerGems Sensors & Controls
Reach Compliance Codeunknown
Maximum accuracy(%)0.25%
shellSTAINLESS STEEL
Nominal offset0V
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range0-10V
Output typeANALOG VOLTAGE
Package Shape/FormCYLINDRICAL
port type1/4 NPT
Maximum pressure range
Minimum pressure range-15 Psi
Pressure sensing modeGAGE
Sensor/Transducer TypePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage35 V
Minimum supply voltage1.5 V
Termination typeDIN 9.4MM W/MATE
Base Number Matches1
Play with Raspberry Pi 3 + Raspberry Pi support package installation of MATLAB/Simulink
Matlab/Simulink supports programming the Raspberry Pi using the matlab interface and simulink modeling. Of course, it is mainly used for academic research such as hardware interfaces, numerical calcul...
mars4zhu Embedded System
Ucos/II Chinese version
Ucos/II Chinese version...
15075039ZQ Real-time operating system RTOS
LPC1114, after using external interrupt, use IIC to read AT24C256, the problem occurs
In LPC1114, after using external interrupt, I use IIC to read AT24C256. The problem occurs. The reading is normal without interrupt, but as soon as the interrupt is entered, the reading goes wrong. Th...
super00peng NXP MCU
Minimum Linux system production routine
1. What is BabyLinux   BabyLinux is not a complete distribution. It is a very small Linux system on a floppy disk, using the original complete Linux kernel source code and compilation tools, and the p...
芝锐 Linux and Android
Does the bootloader need to pass startup parameters?
I have a bootloader that has copied NK to sdram. I wonder if I can jump directly to the address of sdram-NK. Is it still necessary to start it? For example, parameter passing, etc. Thank you so much....
86814429 Embedded System
Serial Port Tool DNW
...
幸福的娃 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2862  2682  2882  1413  2239  58  54  59  29  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号