Slotted core ribbon
4-96 fibers TOL 405 1001
Indoor/outdoor cable 4-fibers ribbon GASQBDUV dielectric
Features
•
4-fiber ribbon
•
Slotted core
•
Flame-retardant
•
Low smoke halogen-free
•
Pre-terminated on request
•
Dielectric
The
GASQBDUV
cable is a 4-fiber ribbon
cable for indoor/outdoor installation.
The cable is of the slotted core design,
which enables a cable with superior fiber
protection. Each of the six slots contains 1-
4 ribbons of the 4-fiber type.
Being completely dielectric it can be
installed in environments where there can
be electrical interference, for example
adjacent to power lines.
The versatility of this cable design and the
improved splicing properties of the ribbon
technology, reduce the cost of installation.
The cable sheath should be protected from
direct sunlight and moisture.
28701-TOL 405 1001 Uen Rev C
Slotted core ribbon
4-96 fibers TOL 405 1001
Typical data
Temperature range
Operation
Storage
Installation
Bending radius
Temporarily unloaded
Permanent (one turn) and
during installation
Tensile force
During installation
Permanently
Crush resi stance
≤
6.0
kN/10cm
Flame resistance
According to
Water penetration
According to
Delivery lengths
On drum
Attenuation @ 1310nm
@ 1550nm
2, 4, 6 or 8 km
Order information
Product number
No. of
fibers
4
8
12
24
32
48
72
96
Diameter
[mm]
13
13
13
13
13
13
14.5
14.5
Weight
[kg/km]
166
166
166
166
166
166
196
196
-30 till +60°C
-40 till +70°C
-15 till +50°C
≥ 10xcable D
≥ 15xcable D
≤ 2.0 kN
≤ 1.5 kN
TOL 405 1001/4A
TOL 405 1001/8A
TOL 405 1001/12A
TOL 405 1001/24A
TOL 405 1001/32A
TOL 405 1001/48A
TOL 405 1001/72A
TOL 405 1001/96A
The order number corresponds to a cable with
single-mode G652.D fibers colored according to
standard Ericsson color code (see product
information “Standard Ericsson fiber color
code”).
Other versions with other fiber types, fiber colors
and specific technical properties are available on
request.
Design
1 Fiber ............................................... Silica, acrylate
2 Four fiber ribbon ............................. Silica, acrylate
3 Slotted core strength member ........ Glass fiber reinforced
plastic
4 Slotted core .................................... Polyethylene
5 Water blocking................................ Water swelling tape
6 Sheath ............................................ Polyethylene,
flame-retardant,
halogen-free (green)
IEC 60332-3-24
IEC 60794-1-2-
F5B
Transmi ssi on CHARACTERISTICS
0.36 dB/km
0.23 dB/km
Mechanic al and environmental test in
accordance with IEC 60794.1
Fiber parameters and tests according to the
IEC series 60793-2 and 60793-1
28701-TOL 405 1001 Uen Rev D
www.eric sson.com
Cables & Interconnect
Phone: +46 10 7190000
Ericsson AB 2012
2 (2)